Cargando…

Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting

This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA cond...

Descripción completa

Detalles Bibliográficos
Autores principales: Routen, Ashley C., Upton, Dominic, Edwards, Martin G., Peters, Derek M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Akademia Wychowania Fizycznego w Katowicach 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3588665/
https://www.ncbi.nlm.nih.gov/pubmed/23487398
http://dx.doi.org/10.2478/v10078-012-0002-z
_version_ 1782261608716697600
author Routen, Ashley C.
Upton, Dominic
Edwards, Martin G.
Peters, Derek M.
author_facet Routen, Ashley C.
Upton, Dominic
Edwards, Martin G.
Peters, Derek M.
author_sort Routen, Ashley C.
collection PubMed
description This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4 activity counts displayed acceptable reliability according to CV in both conditions (ConMPA: CVintra = 4.6%, APEintra = 6.6%, CVinter = 6.4%, APEinter = 5.2%; ConVPA: CVintra = 3.9%, APEintra = 5.6%, CVinter = 5.9%, APEinter = 4.7%). When counts were re-categorised into minutes of MPA and VPA, lower CV values were observed (ConMPA: CVintra = 3.2%, APEintra = 4.5%, CVinter = 4.3%, APEinter = 3.2%; ConVPA: CVintra = 0.0%, APEintra = 0.0%, CVinter = 0.0%, APEinter = 0.0%). When activity counts were re-categorised as minutes of MVPA, excellent reliability was observed (CVintra, APEintra, CVinter, and APEinter = 0.0%) in both conditions. Mean AW4 activity counts exhibit reliability statistics comparable to other accelerometers. Reliability is improved when activity counts are re-categorised as time spent in MPA and VPA, with greatest reliability obtained when counts are recategorised as time spent in MVPA. As MVPA is the subcomponent of physical activity most associated with health benefits it would appear that the AW4 is reliable for measuring time spent in this health enhancing intensity category, at least from testing in a mechanical laboratory setting.
format Online
Article
Text
id pubmed-3588665
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Akademia Wychowania Fizycznego w Katowicach
record_format MEDLINE/PubMed
spelling pubmed-35886652013-03-13 Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting Routen, Ashley C. Upton, Dominic Edwards, Martin G. Peters, Derek M. J Hum Kinet Research Article This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4 activity counts displayed acceptable reliability according to CV in both conditions (ConMPA: CVintra = 4.6%, APEintra = 6.6%, CVinter = 6.4%, APEinter = 5.2%; ConVPA: CVintra = 3.9%, APEintra = 5.6%, CVinter = 5.9%, APEinter = 4.7%). When counts were re-categorised into minutes of MPA and VPA, lower CV values were observed (ConMPA: CVintra = 3.2%, APEintra = 4.5%, CVinter = 4.3%, APEinter = 3.2%; ConVPA: CVintra = 0.0%, APEintra = 0.0%, CVinter = 0.0%, APEinter = 0.0%). When activity counts were re-categorised as minutes of MVPA, excellent reliability was observed (CVintra, APEintra, CVinter, and APEinter = 0.0%) in both conditions. Mean AW4 activity counts exhibit reliability statistics comparable to other accelerometers. Reliability is improved when activity counts are re-categorised as time spent in MPA and VPA, with greatest reliability obtained when counts are recategorised as time spent in MVPA. As MVPA is the subcomponent of physical activity most associated with health benefits it would appear that the AW4 is reliable for measuring time spent in this health enhancing intensity category, at least from testing in a mechanical laboratory setting. Akademia Wychowania Fizycznego w Katowicach 2012-04-03 /pmc/articles/PMC3588665/ /pubmed/23487398 http://dx.doi.org/10.2478/v10078-012-0002-z Text en © Editorial Committee of Journal of Human Kinetics http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Research Article
Routen, Ashley C.
Upton, Dominic
Edwards, Martin G.
Peters, Derek M.
Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title_full Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title_fullStr Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title_full_unstemmed Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title_short Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
title_sort intra- and inter-instrument reliability of the actiwatch 4 accelerometer in a mechanical laboratory setting
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3588665/
https://www.ncbi.nlm.nih.gov/pubmed/23487398
http://dx.doi.org/10.2478/v10078-012-0002-z
work_keys_str_mv AT routenashleyc intraandinterinstrumentreliabilityoftheactiwatch4accelerometerinamechanicallaboratorysetting
AT uptondominic intraandinterinstrumentreliabilityoftheactiwatch4accelerometerinamechanicallaboratorysetting
AT edwardsmarting intraandinterinstrumentreliabilityoftheactiwatch4accelerometerinamechanicallaboratorysetting
AT petersderekm intraandinterinstrumentreliabilityoftheactiwatch4accelerometerinamechanicallaboratorysetting