Cargando…

Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses

We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single dose...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwata, Hiromitsu, Matsufuji, Naruhiro, Toshito, Toshiyuki, Akagi, Takashi, Otsuka, Shinya, Shibamoto, Yuta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589927/
https://www.ncbi.nlm.nih.gov/pubmed/23077237
http://dx.doi.org/10.1093/jrr/rrs089
_version_ 1782261802867884032
author Iwata, Hiromitsu
Matsufuji, Naruhiro
Toshito, Toshiyuki
Akagi, Takashi
Otsuka, Shinya
Shibamoto, Yuta
author_facet Iwata, Hiromitsu
Matsufuji, Naruhiro
Toshito, Toshiyuki
Akagi, Takashi
Otsuka, Shinya
Shibamoto, Yuta
author_sort Iwata, Hiromitsu
collection PubMed
description We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single doses of 2–12 Gy or 2 or 3 fractions of 4 or 5 Gy each, and that of V79 spheroids receiving single doses of 5–26 Gy or 2–5 fractions of 5–12 Gy, were analyzed. Single and fractionated doses to actually reduce cell survival to the same level were determined by a colony assay. Single doses used in the experiments and surviving fractions at the doses were substituted into equations of the RCR, MT and LQ models in the calculation software Mathematica, and each parameter coefficient was computed. Thereafter, using the coefficients and the three models, equivalent single doses for the hypofractionated doses were calculated. They were then compared with actually-determined equivalent single doses for the hypofractionated doses. The equivalent single doses calculated using the RCR, MT and LQ models tended to be lower than the actually determined equivalent single doses. The LQ model seemed to fit relatively well at doses of 5 Gy or less. At 6 Gy or higher doses, the RCR and MT models seemed to be more reliable than the LQ model. In hypofractionated stereotactic radiotherapy, the LQ model should not be used, and conversion models incorporating the concept of the RCR or MT models, such as the generalized linear-quadratic models, appear to be more suitable.
format Online
Article
Text
id pubmed-3589927
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-35899272013-03-06 Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses Iwata, Hiromitsu Matsufuji, Naruhiro Toshito, Toshiyuki Akagi, Takashi Otsuka, Shinya Shibamoto, Yuta J Radiat Res Physics We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single doses of 2–12 Gy or 2 or 3 fractions of 4 or 5 Gy each, and that of V79 spheroids receiving single doses of 5–26 Gy or 2–5 fractions of 5–12 Gy, were analyzed. Single and fractionated doses to actually reduce cell survival to the same level were determined by a colony assay. Single doses used in the experiments and surviving fractions at the doses were substituted into equations of the RCR, MT and LQ models in the calculation software Mathematica, and each parameter coefficient was computed. Thereafter, using the coefficients and the three models, equivalent single doses for the hypofractionated doses were calculated. They were then compared with actually-determined equivalent single doses for the hypofractionated doses. The equivalent single doses calculated using the RCR, MT and LQ models tended to be lower than the actually determined equivalent single doses. The LQ model seemed to fit relatively well at doses of 5 Gy or less. At 6 Gy or higher doses, the RCR and MT models seemed to be more reliable than the LQ model. In hypofractionated stereotactic radiotherapy, the LQ model should not be used, and conversion models incorporating the concept of the RCR or MT models, such as the generalized linear-quadratic models, appear to be more suitable. Oxford University Press 2013-03 2012-10-16 /pmc/articles/PMC3589927/ /pubmed/23077237 http://dx.doi.org/10.1093/jrr/rrs089 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Physics
Iwata, Hiromitsu
Matsufuji, Naruhiro
Toshito, Toshiyuki
Akagi, Takashi
Otsuka, Shinya
Shibamoto, Yuta
Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title_full Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title_fullStr Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title_full_unstemmed Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title_short Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
title_sort compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
topic Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589927/
https://www.ncbi.nlm.nih.gov/pubmed/23077237
http://dx.doi.org/10.1093/jrr/rrs089
work_keys_str_mv AT iwatahiromitsu compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses
AT matsufujinaruhiro compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses
AT toshitotoshiyuki compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses
AT akagitakashi compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses
AT otsukashinya compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses
AT shibamotoyuta compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses