Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses
We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single dose...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589927/ https://www.ncbi.nlm.nih.gov/pubmed/23077237 http://dx.doi.org/10.1093/jrr/rrs089 |
_version_ | 1782261802867884032 |
---|---|
author | Iwata, Hiromitsu Matsufuji, Naruhiro Toshito, Toshiyuki Akagi, Takashi Otsuka, Shinya Shibamoto, Yuta |
author_facet | Iwata, Hiromitsu Matsufuji, Naruhiro Toshito, Toshiyuki Akagi, Takashi Otsuka, Shinya Shibamoto, Yuta |
author_sort | Iwata, Hiromitsu |
collection | PubMed |
description | We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single doses of 2–12 Gy or 2 or 3 fractions of 4 or 5 Gy each, and that of V79 spheroids receiving single doses of 5–26 Gy or 2–5 fractions of 5–12 Gy, were analyzed. Single and fractionated doses to actually reduce cell survival to the same level were determined by a colony assay. Single doses used in the experiments and surviving fractions at the doses were substituted into equations of the RCR, MT and LQ models in the calculation software Mathematica, and each parameter coefficient was computed. Thereafter, using the coefficients and the three models, equivalent single doses for the hypofractionated doses were calculated. They were then compared with actually-determined equivalent single doses for the hypofractionated doses. The equivalent single doses calculated using the RCR, MT and LQ models tended to be lower than the actually determined equivalent single doses. The LQ model seemed to fit relatively well at doses of 5 Gy or less. At 6 Gy or higher doses, the RCR and MT models seemed to be more reliable than the LQ model. In hypofractionated stereotactic radiotherapy, the LQ model should not be used, and conversion models incorporating the concept of the RCR or MT models, such as the generalized linear-quadratic models, appear to be more suitable. |
format | Online Article Text |
id | pubmed-3589927 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-35899272013-03-06 Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses Iwata, Hiromitsu Matsufuji, Naruhiro Toshito, Toshiyuki Akagi, Takashi Otsuka, Shinya Shibamoto, Yuta J Radiat Res Physics We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single doses of 2–12 Gy or 2 or 3 fractions of 4 or 5 Gy each, and that of V79 spheroids receiving single doses of 5–26 Gy or 2–5 fractions of 5–12 Gy, were analyzed. Single and fractionated doses to actually reduce cell survival to the same level were determined by a colony assay. Single doses used in the experiments and surviving fractions at the doses were substituted into equations of the RCR, MT and LQ models in the calculation software Mathematica, and each parameter coefficient was computed. Thereafter, using the coefficients and the three models, equivalent single doses for the hypofractionated doses were calculated. They were then compared with actually-determined equivalent single doses for the hypofractionated doses. The equivalent single doses calculated using the RCR, MT and LQ models tended to be lower than the actually determined equivalent single doses. The LQ model seemed to fit relatively well at doses of 5 Gy or less. At 6 Gy or higher doses, the RCR and MT models seemed to be more reliable than the LQ model. In hypofractionated stereotactic radiotherapy, the LQ model should not be used, and conversion models incorporating the concept of the RCR or MT models, such as the generalized linear-quadratic models, appear to be more suitable. Oxford University Press 2013-03 2012-10-16 /pmc/articles/PMC3589927/ /pubmed/23077237 http://dx.doi.org/10.1093/jrr/rrs089 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited |
spellingShingle | Physics Iwata, Hiromitsu Matsufuji, Naruhiro Toshito, Toshiyuki Akagi, Takashi Otsuka, Shinya Shibamoto, Yuta Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title | Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title_full | Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title_fullStr | Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title_full_unstemmed | Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title_short | Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
title_sort | compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting hypofractionated radiation doses to single doses |
topic | Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589927/ https://www.ncbi.nlm.nih.gov/pubmed/23077237 http://dx.doi.org/10.1093/jrr/rrs089 |
work_keys_str_mv | AT iwatahiromitsu compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses AT matsufujinaruhiro compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses AT toshitotoshiyuki compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses AT akagitakashi compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses AT otsukashinya compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses AT shibamotoyuta compatibilityoftherepairableconditionallyrepairablemultitargetandlinearquadraticmodelsinconvertinghypofractionatedradiationdosestosingledoses |