Cargando…

An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements

The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dos...

Descripción completa

Detalles Bibliográficos
Autores principales: Apipunyasopon, Lukkana, Srisatit, Somyot, Phaisangittisakul, Nakorn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589935/
https://www.ncbi.nlm.nih.gov/pubmed/23104898
http://dx.doi.org/10.1093/jrr/rrs097
_version_ 1782261804701843456
author Apipunyasopon, Lukkana
Srisatit, Somyot
Phaisangittisakul, Nakorn
author_facet Apipunyasopon, Lukkana
Srisatit, Somyot
Phaisangittisakul, Nakorn
author_sort Apipunyasopon, Lukkana
collection PubMed
description The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased proportionally with the field size from approximately 10% to 30%. The measurements were also taken using four common detectors: TLD chips, PFD dosimeter, parallel-plate and cylindrical ionization chamber, and compared with MC simulated data, which served as the gold standard in our study. The surface doses obtained from each detector were derived from the extrapolation of the measured depth doses near the surface and were all found to be higher than that of the MC simulation. The lowest and highest over-responses in the surface dose measurement were found with the TLD chip and the CC13 cylindrical ionization chamber, respectively. Increasing the field size increased the percentage surface dose almost linearly in the various dosimeters and also in the MC simulation. Interestingly, the use of the CC13 ionization chamber eliminates the high gradient feature of the depth dose near the surface. The correction factors for the measured surface dose from each dosimeter for square field sizes of between 5 × 5 and 20 × 20 cm(2)are introduced.
format Online
Article
Text
id pubmed-3589935
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-35899352013-03-06 An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements Apipunyasopon, Lukkana Srisatit, Somyot Phaisangittisakul, Nakorn J Radiat Res Physics The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased proportionally with the field size from approximately 10% to 30%. The measurements were also taken using four common detectors: TLD chips, PFD dosimeter, parallel-plate and cylindrical ionization chamber, and compared with MC simulated data, which served as the gold standard in our study. The surface doses obtained from each detector were derived from the extrapolation of the measured depth doses near the surface and were all found to be higher than that of the MC simulation. The lowest and highest over-responses in the surface dose measurement were found with the TLD chip and the CC13 cylindrical ionization chamber, respectively. Increasing the field size increased the percentage surface dose almost linearly in the various dosimeters and also in the MC simulation. Interestingly, the use of the CC13 ionization chamber eliminates the high gradient feature of the depth dose near the surface. The correction factors for the measured surface dose from each dosimeter for square field sizes of between 5 × 5 and 20 × 20 cm(2)are introduced. Oxford University Press 2013-03 2012-10-26 /pmc/articles/PMC3589935/ /pubmed/23104898 http://dx.doi.org/10.1093/jrr/rrs097 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited
spellingShingle Physics
Apipunyasopon, Lukkana
Srisatit, Somyot
Phaisangittisakul, Nakorn
An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title_full An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title_fullStr An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title_full_unstemmed An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title_short An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements
title_sort investigation of the depth dose in the build-up region, and surface dose for a 6-mv therapeutic photon beam: monte carlo simulation and measurements
topic Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589935/
https://www.ncbi.nlm.nih.gov/pubmed/23104898
http://dx.doi.org/10.1093/jrr/rrs097
work_keys_str_mv AT apipunyasoponlukkana aninvestigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements
AT srisatitsomyot aninvestigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements
AT phaisangittisakulnakorn aninvestigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements
AT apipunyasoponlukkana investigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements
AT srisatitsomyot investigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements
AT phaisangittisakulnakorn investigationofthedepthdoseinthebuildupregionandsurfacedosefora6mvtherapeuticphotonbeammontecarlosimulationandmeasurements