Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation

OBJECTIVE: The purpose of this study was to evaluate the accuracy of a preoperative MRI with microscopy coils in determining the primary tumor thickness of malignant melanoma with histopathologic correlation. MATERIALS AND METHODS: Eleven patients with histopathologically confirmed malignant melanom...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Yusuhn, Choi, Jung-Ah, Chung, Jin-Haeng, Hong, Sung Hwan, Kang, Heung Sik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3590342/
https://www.ncbi.nlm.nih.gov/pubmed/23482432
http://dx.doi.org/10.3348/kjr.2013.14.2.287
_version_ 1782261848108695552
author Kang, Yusuhn
Choi, Jung-Ah
Chung, Jin-Haeng
Hong, Sung Hwan
Kang, Heung Sik
author_facet Kang, Yusuhn
Choi, Jung-Ah
Chung, Jin-Haeng
Hong, Sung Hwan
Kang, Heung Sik
author_sort Kang, Yusuhn
collection PubMed
description OBJECTIVE: The purpose of this study was to evaluate the accuracy of a preoperative MRI with microscopy coils in determining the primary tumor thickness of malignant melanoma with histopathologic correlation. MATERIALS AND METHODS: Eleven patients with histopathologically confirmed malignant melanoma were included in this study. MR images of the tumors were obtained with a 47-mm microscopy coil on 1.5T MR scanners and were evaluated by two radiologists, who assessed the thickness of the primary tumor on T2-weighted images (T2WI) and gadolinium-enhanced T1-weighted images with fat suppression (Gd-T1WI) and compared the results with the histopathologic findings as the reference standard. Correlations between tumor thickness on MRI and histopathologic examination were assessed using concordance correlation coefficients (CCCs). Inter- and intraobserver variabilities of tumor measurements were also assessed by intraclass correlation coefficient (ICC). RESULTS: Among the 11 cases included in the study, 10 cases from the same number of patients were managed with surgical excision and one case was confirmed with punch biopsy. The primary tumor thickness measured on T2WI showed better correlation with histopathologic results, as compared with measurements taken on Gd-T1WI: the CCC of measurements on T2WI ranged from 0.64 to 0.78, indicating a substantial agreement, whereas the CCC of measurements on Gd-T1WI ranged from 0.50 to 0.61, indicating a moderate to substantial agreement. Inter- and intraobserver agreements of readers 1 and 2 were excellent for both T2WI and Gd-T1WI, with ICC ranging from 0.86 to 0.99. CONCLUSION: MR imaging with microscopy coils may be an accurate technique in the preoperative assessment of tumor thickness in malignant melanoma, especially on T2-weighted images.
format Online
Article
Text
id pubmed-3590342
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-35903422013-03-12 Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation Kang, Yusuhn Choi, Jung-Ah Chung, Jin-Haeng Hong, Sung Hwan Kang, Heung Sik Korean J Radiol Musculoskeletal Imaging OBJECTIVE: The purpose of this study was to evaluate the accuracy of a preoperative MRI with microscopy coils in determining the primary tumor thickness of malignant melanoma with histopathologic correlation. MATERIALS AND METHODS: Eleven patients with histopathologically confirmed malignant melanoma were included in this study. MR images of the tumors were obtained with a 47-mm microscopy coil on 1.5T MR scanners and were evaluated by two radiologists, who assessed the thickness of the primary tumor on T2-weighted images (T2WI) and gadolinium-enhanced T1-weighted images with fat suppression (Gd-T1WI) and compared the results with the histopathologic findings as the reference standard. Correlations between tumor thickness on MRI and histopathologic examination were assessed using concordance correlation coefficients (CCCs). Inter- and intraobserver variabilities of tumor measurements were also assessed by intraclass correlation coefficient (ICC). RESULTS: Among the 11 cases included in the study, 10 cases from the same number of patients were managed with surgical excision and one case was confirmed with punch biopsy. The primary tumor thickness measured on T2WI showed better correlation with histopathologic results, as compared with measurements taken on Gd-T1WI: the CCC of measurements on T2WI ranged from 0.64 to 0.78, indicating a substantial agreement, whereas the CCC of measurements on Gd-T1WI ranged from 0.50 to 0.61, indicating a moderate to substantial agreement. Inter- and intraobserver agreements of readers 1 and 2 were excellent for both T2WI and Gd-T1WI, with ICC ranging from 0.86 to 0.99. CONCLUSION: MR imaging with microscopy coils may be an accurate technique in the preoperative assessment of tumor thickness in malignant melanoma, especially on T2-weighted images. The Korean Society of Radiology 2013 2013-02-22 /pmc/articles/PMC3590342/ /pubmed/23482432 http://dx.doi.org/10.3348/kjr.2013.14.2.287 Text en Copyright © 2013 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Kang, Yusuhn
Choi, Jung-Ah
Chung, Jin-Haeng
Hong, Sung Hwan
Kang, Heung Sik
Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title_full Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title_fullStr Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title_full_unstemmed Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title_short Accuracy of Preoperative MRI with Microscopy Coil in Evaluation of Primary Tumor Thickness of Malignant Melanoma of the Skin with Histopathologic Correlation
title_sort accuracy of preoperative mri with microscopy coil in evaluation of primary tumor thickness of malignant melanoma of the skin with histopathologic correlation
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3590342/
https://www.ncbi.nlm.nih.gov/pubmed/23482432
http://dx.doi.org/10.3348/kjr.2013.14.2.287
work_keys_str_mv AT kangyusuhn accuracyofpreoperativemriwithmicroscopycoilinevaluationofprimarytumorthicknessofmalignantmelanomaoftheskinwithhistopathologiccorrelation
AT choijungah accuracyofpreoperativemriwithmicroscopycoilinevaluationofprimarytumorthicknessofmalignantmelanomaoftheskinwithhistopathologiccorrelation
AT chungjinhaeng accuracyofpreoperativemriwithmicroscopycoilinevaluationofprimarytumorthicknessofmalignantmelanomaoftheskinwithhistopathologiccorrelation
AT hongsunghwan accuracyofpreoperativemriwithmicroscopycoilinevaluationofprimarytumorthicknessofmalignantmelanomaoftheskinwithhistopathologiccorrelation
AT kangheungsik accuracyofpreoperativemriwithmicroscopycoilinevaluationofprimarytumorthicknessofmalignantmelanomaoftheskinwithhistopathologiccorrelation