Cargando…

A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications

Objective: In this study, we aimed to make a computer program that calculates approximate radiation dose received by embryo/fetus in nuclear medicine applications. Material and Methods: Radiation dose values per MBq-1 received by embryo/fetus in nuclear medicine applications were gathered from liter...

Descripción completa

Detalles Bibliográficos
Autores principales: Bayram, Tuncay, Sönmez, Bircan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3590962/
https://www.ncbi.nlm.nih.gov/pubmed/23487527
http://dx.doi.org/10.4274/Mirt.99
_version_ 1782261953494777856
author Bayram, Tuncay
Sönmez, Bircan
author_facet Bayram, Tuncay
Sönmez, Bircan
author_sort Bayram, Tuncay
collection PubMed
description Objective: In this study, we aimed to make a computer program that calculates approximate radiation dose received by embryo/fetus in nuclear medicine applications. Material and Methods: Radiation dose values per MBq-1 received by embryo/fetus in nuclear medicine applications were gathered from literature for various stages of pregnancy. These values were embedded in the computer code, which was written in Fortran 90 program language. Results: The computer program called nmfdose covers almost all radiopharmaceuticals used in nuclear medicine applications. Approximate radiation dose received by embryo/fetus can be calculated easily at a few steps using this computer program. Conclusion: Although there are some constraints on using the program for some special cases, nmfdose is useful and it provides practical solution for calculation of approximate dose to embryo/fetus in nuclear medicine applications. Conflict of interest:None declared.
format Online
Article
Text
id pubmed-3590962
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-35909622013-03-13 A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications Bayram, Tuncay Sönmez, Bircan Mol Imaging Radionucl Ther Original Article Objective: In this study, we aimed to make a computer program that calculates approximate radiation dose received by embryo/fetus in nuclear medicine applications. Material and Methods: Radiation dose values per MBq-1 received by embryo/fetus in nuclear medicine applications were gathered from literature for various stages of pregnancy. These values were embedded in the computer code, which was written in Fortran 90 program language. Results: The computer program called nmfdose covers almost all radiopharmaceuticals used in nuclear medicine applications. Approximate radiation dose received by embryo/fetus can be calculated easily at a few steps using this computer program. Conclusion: Although there are some constraints on using the program for some special cases, nmfdose is useful and it provides practical solution for calculation of approximate dose to embryo/fetus in nuclear medicine applications. Conflict of interest:None declared. Galenos Publishing 2012-04 2012-04-01 /pmc/articles/PMC3590962/ /pubmed/23487527 http://dx.doi.org/10.4274/Mirt.99 Text en © Molecular Imaging and Radionuclide Therapy, Published by Galenos Publishing. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Bayram, Tuncay
Sönmez, Bircan
A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title_full A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title_fullStr A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title_full_unstemmed A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title_short A Computer Program for Calculation of Approximate Embryo/Fetus Radiation Dose in Nuclear Medicine Applications
title_sort computer program for calculation of approximate embryo/fetus radiation dose in nuclear medicine applications
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3590962/
https://www.ncbi.nlm.nih.gov/pubmed/23487527
http://dx.doi.org/10.4274/Mirt.99
work_keys_str_mv AT bayramtuncay acomputerprogramforcalculationofapproximateembryofetusradiationdoseinnuclearmedicineapplications
AT sonmezbircan acomputerprogramforcalculationofapproximateembryofetusradiationdoseinnuclearmedicineapplications
AT bayramtuncay computerprogramforcalculationofapproximateembryofetusradiationdoseinnuclearmedicineapplications
AT sonmezbircan computerprogramforcalculationofapproximateembryofetusradiationdoseinnuclearmedicineapplications