Cargando…
The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters
PURPOSE: To investigate the effect of simultaneously performed fluorescein angiography (FA) on full-field electroretinography (ffERG) parameters. METHOD: Scotopic and photopic ffERG were performed immediately and 60 minutes after conventional FA in patients with retinal photoreceptor disorders; a-an...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ophthalmic Research Center
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3595589/ https://www.ncbi.nlm.nih.gov/pubmed/23503687 |
_version_ | 1782262426392068096 |
---|---|
author | Azarmina, Mohsen Moradian, Siamak Azarmina, Hossein |
author_facet | Azarmina, Mohsen Moradian, Siamak Azarmina, Hossein |
author_sort | Azarmina, Mohsen |
collection | PubMed |
description | PURPOSE: To investigate the effect of simultaneously performed fluorescein angiography (FA) on full-field electroretinography (ffERG) parameters. METHOD: Scotopic and photopic ffERG were performed immediately and 60 minutes after conventional FA in patients with retinal photoreceptor disorders; a-and b-wave amplitudes were compared between recordings obtained at the two time intervals in each patient. RESULTS: Ten eyes of five (3 male and 2 female) patients with mean age of 19.6±3.8 (range, 15-25) years were studied. Intravenous fluorescein administration caused an immediate reduction in ERG waves which was most prominent in rod and maximal combined responses. Mean a-wave amplitude in maximal combined response, rod response and cone response ERGs was 46.0±18.8, 8.0±7.0 and 5.1±2.0 mv immediately after FA which was increased to 79.0±30.0, 21.5± 22.5 and 6.5±2.4 mv 60 minutes afterwards, respectively (P<0.005 for all comparisons). Mean b-wave amplitude in the same order was 91.0±17.5, 47.7±17.2 and 17.3±14.7mv which was increased to 145.0±54.3, 91.8±48.1 and 20.0±17.7 mv respectively, 60 minutes after FA (P<0.005 for all comparisons). CONCLUSION: The amplitude of ERG a- and b-waves under scotopic and photopic conditions increased significantly one hour after FA. These changes may be explained by disappearance of phototoxic and bleaching effects of strong light exposure from the light source of the angiography machine and fluorescein molecule on retinal photoreceptors. |
format | Online Article Text |
id | pubmed-3595589 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Ophthalmic Research Center |
record_format | MEDLINE/PubMed |
spelling | pubmed-35955892013-03-15 The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters Azarmina, Mohsen Moradian, Siamak Azarmina, Hossein J Ophthalmic Vis Res Original Article PURPOSE: To investigate the effect of simultaneously performed fluorescein angiography (FA) on full-field electroretinography (ffERG) parameters. METHOD: Scotopic and photopic ffERG were performed immediately and 60 minutes after conventional FA in patients with retinal photoreceptor disorders; a-and b-wave amplitudes were compared between recordings obtained at the two time intervals in each patient. RESULTS: Ten eyes of five (3 male and 2 female) patients with mean age of 19.6±3.8 (range, 15-25) years were studied. Intravenous fluorescein administration caused an immediate reduction in ERG waves which was most prominent in rod and maximal combined responses. Mean a-wave amplitude in maximal combined response, rod response and cone response ERGs was 46.0±18.8, 8.0±7.0 and 5.1±2.0 mv immediately after FA which was increased to 79.0±30.0, 21.5± 22.5 and 6.5±2.4 mv 60 minutes afterwards, respectively (P<0.005 for all comparisons). Mean b-wave amplitude in the same order was 91.0±17.5, 47.7±17.2 and 17.3±14.7mv which was increased to 145.0±54.3, 91.8±48.1 and 20.0±17.7 mv respectively, 60 minutes after FA (P<0.005 for all comparisons). CONCLUSION: The amplitude of ERG a- and b-waves under scotopic and photopic conditions increased significantly one hour after FA. These changes may be explained by disappearance of phototoxic and bleaching effects of strong light exposure from the light source of the angiography machine and fluorescein molecule on retinal photoreceptors. Ophthalmic Research Center 2012-10 /pmc/articles/PMC3595589/ /pubmed/23503687 Text en © 2012 Ophthalmic Research Center, Shahid Beheshti University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Azarmina, Mohsen Moradian, Siamak Azarmina, Hossein The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title | The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title_full | The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title_fullStr | The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title_full_unstemmed | The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title_short | The Effect of Fluorescein Angiography on Full-Field Electroretinography Parameters |
title_sort | effect of fluorescein angiography on full-field electroretinography parameters |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3595589/ https://www.ncbi.nlm.nih.gov/pubmed/23503687 |
work_keys_str_mv | AT azarminamohsen theeffectoffluoresceinangiographyonfullfieldelectroretinographyparameters AT moradiansiamak theeffectoffluoresceinangiographyonfullfieldelectroretinographyparameters AT azarminahossein theeffectoffluoresceinangiographyonfullfieldelectroretinographyparameters AT azarminamohsen effectoffluoresceinangiographyonfullfieldelectroretinographyparameters AT moradiansiamak effectoffluoresceinangiographyonfullfieldelectroretinographyparameters AT azarminahossein effectoffluoresceinangiographyonfullfieldelectroretinographyparameters |