Cargando…

Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography

Magnetic resonance arthrography (MRA) is commonly used to detect labral tears of the hip. Complications of MRA are unusual and include minor reactions such as chemical synovitis and urticaria. This paper presents a rapidly progressive chondrolysis of the hip in a young patient after arthrography. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Haviv, Barak, Thein, Rafael, Burg, Alon, Heller, Snir, Bronak, Shlomo, Velkes, Steven
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3595689/
https://www.ncbi.nlm.nih.gov/pubmed/23509652
http://dx.doi.org/10.1155/2013/840681
_version_ 1782262443289870336
author Haviv, Barak
Thein, Rafael
Burg, Alon
Heller, Snir
Bronak, Shlomo
Velkes, Steven
author_facet Haviv, Barak
Thein, Rafael
Burg, Alon
Heller, Snir
Bronak, Shlomo
Velkes, Steven
author_sort Haviv, Barak
collection PubMed
description Magnetic resonance arthrography (MRA) is commonly used to detect labral tears of the hip. Complications of MRA are unusual and include minor reactions such as chemical synovitis and urticaria. This paper presents a rapidly progressive chondrolysis of the hip in a young patient after arthrography. The patient had suffered from acute septic arthritis and was treated by emergent arthroscopic surgery followed by appropriate antibiotics. At 18 months of followup, there were no signs of active infection but evidence of joint chondrolysis. Magnetic resonance arthrography (MRA) of the hip is an invasive procedure and should therefore be recommended judiciously. Post-MRA pain is common but often mild and temporary, while post-MRA joint infection is rare; nevertheless, severe joint pain and limitation should raise suspicion for septic hip.
format Online
Article
Text
id pubmed-3595689
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-35956892013-03-18 Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography Haviv, Barak Thein, Rafael Burg, Alon Heller, Snir Bronak, Shlomo Velkes, Steven Case Rep Orthop Case Report Magnetic resonance arthrography (MRA) is commonly used to detect labral tears of the hip. Complications of MRA are unusual and include minor reactions such as chemical synovitis and urticaria. This paper presents a rapidly progressive chondrolysis of the hip in a young patient after arthrography. The patient had suffered from acute septic arthritis and was treated by emergent arthroscopic surgery followed by appropriate antibiotics. At 18 months of followup, there were no signs of active infection but evidence of joint chondrolysis. Magnetic resonance arthrography (MRA) of the hip is an invasive procedure and should therefore be recommended judiciously. Post-MRA pain is common but often mild and temporary, while post-MRA joint infection is rare; nevertheless, severe joint pain and limitation should raise suspicion for septic hip. Hindawi Publishing Corporation 2013 2013-02-24 /pmc/articles/PMC3595689/ /pubmed/23509652 http://dx.doi.org/10.1155/2013/840681 Text en Copyright © 2013 Barak Haviv et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Haviv, Barak
Thein, Rafael
Burg, Alon
Heller, Snir
Bronak, Shlomo
Velkes, Steven
Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title_full Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title_fullStr Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title_full_unstemmed Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title_short Chondrolysis of the Hip following Septic Arthritis: A Rare Complication of Magnetic Resonance Arthrography
title_sort chondrolysis of the hip following septic arthritis: a rare complication of magnetic resonance arthrography
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3595689/
https://www.ncbi.nlm.nih.gov/pubmed/23509652
http://dx.doi.org/10.1155/2013/840681
work_keys_str_mv AT havivbarak chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography
AT theinrafael chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography
AT burgalon chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography
AT hellersnir chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography
AT bronakshlomo chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography
AT velkessteven chondrolysisofthehipfollowingsepticarthritisararecomplicationofmagneticresonancearthrography