Cargando…
Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms
BACKGROUND: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3596147/ https://www.ncbi.nlm.nih.gov/pubmed/23493525 http://dx.doi.org/10.12659/PJR.883769 |
_version_ | 1782262471538507776 |
---|---|
author | Kurosaka, Kenichiro Kawai, Tatsuya Shimohira, Masashi Hashizume, Takuya Ohta, Kengo Suzuki, Yosuke Shibamoto, Yuta |
author_facet | Kurosaka, Kenichiro Kawai, Tatsuya Shimohira, Masashi Hashizume, Takuya Ohta, Kengo Suzuki, Yosuke Shibamoto, Yuta |
author_sort | Kurosaka, Kenichiro |
collection | PubMed |
description | BACKGROUND: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral artery aneurysms (one case of right internal iliac artery aneurysm and one case of splenic artery aneurysm). Repeat coil embolization was successfully performed. CASE REPORT: Case 1. An 80-year-old male patient with right internal iliac artery (IIA) aneurysm underwent coil embolization. Aneurysm was located at the bifurcation of the right IIA and therefore, after making a femorofemoral bypass, the distal part of the right IIA, aneurysm and the common iliac artery were embolized with a coil. One year later, the size of the aneurysm seemed to have increased on CT. However, the details were not determined because of metal artifacts. Thus, time-resolved MRA was performed and showed minute vascular flow inside the aneurysm. Angiography was subsequently performed and blood flow inside the aneurysm was visualized similar to the findings in time-resolved MRA. Coil embolization was performed once more and vascular flow inside the aneurysm disappeared. Case 2. A 36-year-old male patient with a splenic artery aneurysm underwent coil packing with preservation of splenic artery patency. Four years later, coil compaction was suspected in a CT scan, but CT could not evaluate recanalization because of severe metal artifacts. Angiography was subsequently performed, showing recanalization of the aneurysm as did the time-resolved MRA. Therefore, coil embolization of the aneurysm and splenic artery was performed again. CONCLUSIONS: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, it is sometimes difficult to assess recanalization with CT because of artifacts caused by metal. In our cases, recanalization of aneurysms was clearly shown by time-resolved MRA and re-embolization was successfully performed. In conclusion, time-resolved MRA appears to be useful in assessment of recanalization of visceral artery aneurysms after coil embolization. |
format | Online Article Text |
id | pubmed-3596147 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-35961472013-03-14 Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms Kurosaka, Kenichiro Kawai, Tatsuya Shimohira, Masashi Hashizume, Takuya Ohta, Kengo Suzuki, Yosuke Shibamoto, Yuta Pol J Radiol Case Report BACKGROUND: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral artery aneurysms (one case of right internal iliac artery aneurysm and one case of splenic artery aneurysm). Repeat coil embolization was successfully performed. CASE REPORT: Case 1. An 80-year-old male patient with right internal iliac artery (IIA) aneurysm underwent coil embolization. Aneurysm was located at the bifurcation of the right IIA and therefore, after making a femorofemoral bypass, the distal part of the right IIA, aneurysm and the common iliac artery were embolized with a coil. One year later, the size of the aneurysm seemed to have increased on CT. However, the details were not determined because of metal artifacts. Thus, time-resolved MRA was performed and showed minute vascular flow inside the aneurysm. Angiography was subsequently performed and blood flow inside the aneurysm was visualized similar to the findings in time-resolved MRA. Coil embolization was performed once more and vascular flow inside the aneurysm disappeared. Case 2. A 36-year-old male patient with a splenic artery aneurysm underwent coil packing with preservation of splenic artery patency. Four years later, coil compaction was suspected in a CT scan, but CT could not evaluate recanalization because of severe metal artifacts. Angiography was subsequently performed, showing recanalization of the aneurysm as did the time-resolved MRA. Therefore, coil embolization of the aneurysm and splenic artery was performed again. CONCLUSIONS: Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, it is sometimes difficult to assess recanalization with CT because of artifacts caused by metal. In our cases, recanalization of aneurysms was clearly shown by time-resolved MRA and re-embolization was successfully performed. In conclusion, time-resolved MRA appears to be useful in assessment of recanalization of visceral artery aneurysms after coil embolization. International Scientific Literature, Inc. 2013 /pmc/articles/PMC3596147/ /pubmed/23493525 http://dx.doi.org/10.12659/PJR.883769 Text en © Pol J Radiol, 2013 This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited. |
spellingShingle | Case Report Kurosaka, Kenichiro Kawai, Tatsuya Shimohira, Masashi Hashizume, Takuya Ohta, Kengo Suzuki, Yosuke Shibamoto, Yuta Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title | Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title_full | Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title_fullStr | Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title_full_unstemmed | Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title_short | Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
title_sort | time-resolved magnetic resonance angiography for assessment of recanalization after coil embolization of visceral artery aneurysms |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3596147/ https://www.ncbi.nlm.nih.gov/pubmed/23493525 http://dx.doi.org/10.12659/PJR.883769 |
work_keys_str_mv | AT kurosakakenichiro timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT kawaitatsuya timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT shimohiramasashi timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT hashizumetakuya timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT ohtakengo timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT suzukiyosuke timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms AT shibamotoyuta timeresolvedmagneticresonanceangiographyforassessmentofrecanalizationaftercoilembolizationofvisceralarteryaneurysms |