Cargando…

Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

PURPOSE: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). METHODS: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwon, Yee-Seo, Namgoong, Hee, Kim, Jung-Hoon, Cho, In Hee, Kim, Myung Duk, Eom, Tae Gwan, Koo, Ki-Tae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Periodontology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3596634/
https://www.ncbi.nlm.nih.gov/pubmed/23508085
http://dx.doi.org/10.5051/jpis.2013.43.1.41
_version_ 1782262534320947200
author Kwon, Yee-Seo
Namgoong, Hee
Kim, Jung-Hoon
Cho, In Hee
Kim, Myung Duk
Eom, Tae Gwan
Koo, Ki-Tae
author_facet Kwon, Yee-Seo
Namgoong, Hee
Kim, Jung-Hoon
Cho, In Hee
Kim, Myung Duk
Eom, Tae Gwan
Koo, Ki-Tae
author_sort Kwon, Yee-Seo
collection PubMed
description PURPOSE: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). METHODS: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The P1-M1 teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. RESULTS: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. CONCLUSIONS: The existence of microthreads was not a significant factor in mechanical and histological stability.
format Online
Article
Text
id pubmed-3596634
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Korean Academy of Periodontology
record_format MEDLINE/PubMed
spelling pubmed-35966342013-03-18 Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs Kwon, Yee-Seo Namgoong, Hee Kim, Jung-Hoon Cho, In Hee Kim, Myung Duk Eom, Tae Gwan Koo, Ki-Tae J Periodontal Implant Sci Research Article PURPOSE: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). METHODS: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The P1-M1 teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. RESULTS: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. CONCLUSIONS: The existence of microthreads was not a significant factor in mechanical and histological stability. Korean Academy of Periodontology 2013-02 2013-02-28 /pmc/articles/PMC3596634/ /pubmed/23508085 http://dx.doi.org/10.5051/jpis.2013.43.1.41 Text en Copyright © 2013 Korean Academy of Periodontology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/).
spellingShingle Research Article
Kwon, Yee-Seo
Namgoong, Hee
Kim, Jung-Hoon
Cho, In Hee
Kim, Myung Duk
Eom, Tae Gwan
Koo, Ki-Tae
Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title_full Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title_fullStr Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title_full_unstemmed Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title_short Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
title_sort effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3596634/
https://www.ncbi.nlm.nih.gov/pubmed/23508085
http://dx.doi.org/10.5051/jpis.2013.43.1.41
work_keys_str_mv AT kwonyeeseo effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT namgoonghee effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT kimjunghoon effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT choinhee effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT kimmyungduk effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT eomtaegwan effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs
AT kookitae effectofmicrothreadsonremovaltorqueandbonetoimplantcontactanexperimentalstudyinminiaturepigs