Cargando…
Comparison of the dosimetries of 3-dimensions Radiotherapy (3D-RT) with linear accelerator and intensity modulated radiotherapy (IMRT) with helical tomotherapy in children irradiated for neuroblastoma
BACKGROUND: Intensity modulated radiotherapy is an efficient radiotherapy technique to increase dose in target volumes and decrease irradiation dose in organs at risk. This last objective is mainly relevant in children. However, previous results suggested that IMRT could increase low dose, factor of...
Autores principales: | Beneyton, Violaine, Niederst, Claudine, Vigneron, Céline, Meyer, Philippe, Becmeur, François, Marcellin, Luc, Lutz, Patrick, Noel, Georges |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3598555/ https://www.ncbi.nlm.nih.gov/pubmed/22742393 http://dx.doi.org/10.1186/1756-6649-12-2 |
Ejemplares similares
-
Early Experience of Helical Tomotherapy for Hepatobiliary Radiotherapy
por: Massabeau, Carole, et al.
Publicado: (2011) -
Spatially fractionated radiotherapy (GRID) using helical tomotherapy
por: Zhang, Xin, et al.
Publicado: (2016) -
Radiotherapy for Adult Medulloblastoma: Evaluation of Helical Tomotherapy, Volumetric Intensity Modulated Arc Therapy, and Three-Dimensional Conformal Radiotherapy and the Results of Helical Tomotherapy Therapy
por: Zong-wen, Sun, et al.
Publicado: (2018) -
Prospective superficial EPR in-vivo dosimetry study during hypofractionated radiotherapy of breast cancer patients treated with helical tomotherapy
por: Höfel, Sebastian, et al.
Publicado: (2021) -
Low-Dose-Area-Constrained Helical TomoTherapy-Based Whole Breast Radiotherapy and Dosimetric Comparison with Tangential Field-in-Field IMRT
por: Qiu, Jie, et al.
Publicado: (2013)