Cargando…

Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction

BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincte...

Descripción completa

Detalles Bibliográficos
Autores principales: Inatomi, Osamu, Bamba, Shigeki, Shioya, Makoto, Mochizuki, Yosuke, Ban, Hiromitsu, Tsujikawa, Tomoyuki, Saito, Yasuharu, Andoh, Akira, Fujiyama, Yoshihide
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3598933/
https://www.ncbi.nlm.nih.gov/pubmed/23410217
http://dx.doi.org/10.1186/1471-230X-13-31
_version_ 1782262853379555328
author Inatomi, Osamu
Bamba, Shigeki
Shioya, Makoto
Mochizuki, Yosuke
Ban, Hiromitsu
Tsujikawa, Tomoyuki
Saito, Yasuharu
Andoh, Akira
Fujiyama, Yoshihide
author_facet Inatomi, Osamu
Bamba, Shigeki
Shioya, Makoto
Mochizuki, Yosuke
Ban, Hiromitsu
Tsujikawa, Tomoyuki
Saito, Yasuharu
Andoh, Akira
Fujiyama, Yoshihide
author_sort Inatomi, Osamu
collection PubMed
description BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. METHODS: Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. RESULTS: Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). CONCLUSIONS: Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy.
format Online
Article
Text
id pubmed-3598933
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35989332013-03-17 Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction Inatomi, Osamu Bamba, Shigeki Shioya, Makoto Mochizuki, Yosuke Ban, Hiromitsu Tsujikawa, Tomoyuki Saito, Yasuharu Andoh, Akira Fujiyama, Yoshihide BMC Gastroenterol Research Article BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. METHODS: Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. RESULTS: Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). CONCLUSIONS: Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. BioMed Central 2013-02-14 /pmc/articles/PMC3598933/ /pubmed/23410217 http://dx.doi.org/10.1186/1471-230X-13-31 Text en Copyright ©2013 Inatomi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Inatomi, Osamu
Bamba, Shigeki
Shioya, Makoto
Mochizuki, Yosuke
Ban, Hiromitsu
Tsujikawa, Tomoyuki
Saito, Yasuharu
Andoh, Akira
Fujiyama, Yoshihide
Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title_full Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title_fullStr Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title_full_unstemmed Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title_short Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
title_sort threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3598933/
https://www.ncbi.nlm.nih.gov/pubmed/23410217
http://dx.doi.org/10.1186/1471-230X-13-31
work_keys_str_mv AT inatomiosamu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT bambashigeki threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT shioyamakoto threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT mochizukiyosuke threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT banhiromitsu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT tsujikawatomoyuki threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT saitoyasuharu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT andohakira threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction
AT fujiyamayoshihide threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction