Cargando…
Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction
BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincte...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3598933/ https://www.ncbi.nlm.nih.gov/pubmed/23410217 http://dx.doi.org/10.1186/1471-230X-13-31 |
_version_ | 1782262853379555328 |
---|---|
author | Inatomi, Osamu Bamba, Shigeki Shioya, Makoto Mochizuki, Yosuke Ban, Hiromitsu Tsujikawa, Tomoyuki Saito, Yasuharu Andoh, Akira Fujiyama, Yoshihide |
author_facet | Inatomi, Osamu Bamba, Shigeki Shioya, Makoto Mochizuki, Yosuke Ban, Hiromitsu Tsujikawa, Tomoyuki Saito, Yasuharu Andoh, Akira Fujiyama, Yoshihide |
author_sort | Inatomi, Osamu |
collection | PubMed |
description | BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. METHODS: Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. RESULTS: Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). CONCLUSIONS: Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. |
format | Online Article Text |
id | pubmed-3598933 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35989332013-03-17 Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction Inatomi, Osamu Bamba, Shigeki Shioya, Makoto Mochizuki, Yosuke Ban, Hiromitsu Tsujikawa, Tomoyuki Saito, Yasuharu Andoh, Akira Fujiyama, Yoshihide BMC Gastroenterol Research Article BACKGROUND: Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. METHODS: Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. RESULTS: Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). CONCLUSIONS: Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. BioMed Central 2013-02-14 /pmc/articles/PMC3598933/ /pubmed/23410217 http://dx.doi.org/10.1186/1471-230X-13-31 Text en Copyright ©2013 Inatomi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Inatomi, Osamu Bamba, Shigeki Shioya, Makoto Mochizuki, Yosuke Ban, Hiromitsu Tsujikawa, Tomoyuki Saito, Yasuharu Andoh, Akira Fujiyama, Yoshihide Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title | Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title_full | Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title_fullStr | Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title_full_unstemmed | Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title_short | Threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
title_sort | threaded biliary inside stents are a safe and effective therapeutic option in cases of malignant hilar obstruction |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3598933/ https://www.ncbi.nlm.nih.gov/pubmed/23410217 http://dx.doi.org/10.1186/1471-230X-13-31 |
work_keys_str_mv | AT inatomiosamu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT bambashigeki threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT shioyamakoto threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT mochizukiyosuke threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT banhiromitsu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT tsujikawatomoyuki threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT saitoyasuharu threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT andohakira threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction AT fujiyamayoshihide threadedbiliaryinsidestentsareasafeandeffectivetherapeuticoptionincasesofmalignanthilarobstruction |