Cargando…

The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication

BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior...

Descripción completa

Detalles Bibliográficos
Autores principales: Soyfer, Viacheslav, Corn, Benjamin W, Shtraus, Natan, Schifter, Dan, Tempelhof, Haim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599142/
https://www.ncbi.nlm.nih.gov/pubmed/23398716
http://dx.doi.org/10.1186/1748-717X-8-34
_version_ 1782262895791308800
author Soyfer, Viacheslav
Corn, Benjamin W
Shtraus, Natan
Schifter, Dan
Tempelhof, Haim
author_facet Soyfer, Viacheslav
Corn, Benjamin W
Shtraus, Natan
Schifter, Dan
Tempelhof, Haim
author_sort Soyfer, Viacheslav
collection PubMed
description BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior and anterior- posterior fields with 3D plans. RESULTS: The PTV coverage in all comparative plans was similar. V 15 of the bowel in 3D, AP-PA and PA plans was 6.7 Gy (SD 6.47), 39.8 Gy (SD 11.4) and 37.3 Gy (SD15.7), respectively (p < 0.0001). The mean dose to both kidneys was 9.6 Gy (SD 4.8), 4.1 Gy (SD 3.9) and 4.6 Gy (SD 4.4) for appropriate plans (p = 0.002). Maximal dose to the spinal cord was 30.6 Gy (SD 2.1), 33.1 Gy (SD 9.8) and 37.7 Gy (SD 2) for 3D, AP-PA and PA plans. CONCLUSION: 3D conformal treatment planning of lumbar vertebral metastases was significantly better in term of bowel and spinal cord exposure compared to AP-PA and PA techniques. The exposure of the kidneys in 3D plans, while greater than in the comparative plans, did not violate accepted dose-volume thresholds.
format Online
Article
Text
id pubmed-3599142
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35991422013-03-17 The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication Soyfer, Viacheslav Corn, Benjamin W Shtraus, Natan Schifter, Dan Tempelhof, Haim Radiat Oncol Methodology BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior and anterior- posterior fields with 3D plans. RESULTS: The PTV coverage in all comparative plans was similar. V 15 of the bowel in 3D, AP-PA and PA plans was 6.7 Gy (SD 6.47), 39.8 Gy (SD 11.4) and 37.3 Gy (SD15.7), respectively (p < 0.0001). The mean dose to both kidneys was 9.6 Gy (SD 4.8), 4.1 Gy (SD 3.9) and 4.6 Gy (SD 4.4) for appropriate plans (p = 0.002). Maximal dose to the spinal cord was 30.6 Gy (SD 2.1), 33.1 Gy (SD 9.8) and 37.7 Gy (SD 2) for 3D, AP-PA and PA plans. CONCLUSION: 3D conformal treatment planning of lumbar vertebral metastases was significantly better in term of bowel and spinal cord exposure compared to AP-PA and PA techniques. The exposure of the kidneys in 3D plans, while greater than in the comparative plans, did not violate accepted dose-volume thresholds. BioMed Central 2013-02-12 /pmc/articles/PMC3599142/ /pubmed/23398716 http://dx.doi.org/10.1186/1748-717X-8-34 Text en Copyright ©2013 Soyfer et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Soyfer, Viacheslav
Corn, Benjamin W
Shtraus, Natan
Schifter, Dan
Tempelhof, Haim
The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title_full The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title_fullStr The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title_full_unstemmed The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title_short The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
title_sort advantage of 3d conformal treatment of lumbar spine metastases in comparison to traditional pa or ap-pa techniques: restoring an intermediate niche of therapeutic sophistication
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599142/
https://www.ncbi.nlm.nih.gov/pubmed/23398716
http://dx.doi.org/10.1186/1748-717X-8-34
work_keys_str_mv AT soyferviacheslav theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT cornbenjaminw theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT shtrausnatan theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT schifterdan theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT tempelhofhaim theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT soyferviacheslav advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT cornbenjaminw advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT shtrausnatan advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT schifterdan advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication
AT tempelhofhaim advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication