Cargando…
The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication
BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599142/ https://www.ncbi.nlm.nih.gov/pubmed/23398716 http://dx.doi.org/10.1186/1748-717X-8-34 |
_version_ | 1782262895791308800 |
---|---|
author | Soyfer, Viacheslav Corn, Benjamin W Shtraus, Natan Schifter, Dan Tempelhof, Haim |
author_facet | Soyfer, Viacheslav Corn, Benjamin W Shtraus, Natan Schifter, Dan Tempelhof, Haim |
author_sort | Soyfer, Viacheslav |
collection | PubMed |
description | BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior and anterior- posterior fields with 3D plans. RESULTS: The PTV coverage in all comparative plans was similar. V 15 of the bowel in 3D, AP-PA and PA plans was 6.7 Gy (SD 6.47), 39.8 Gy (SD 11.4) and 37.3 Gy (SD15.7), respectively (p < 0.0001). The mean dose to both kidneys was 9.6 Gy (SD 4.8), 4.1 Gy (SD 3.9) and 4.6 Gy (SD 4.4) for appropriate plans (p = 0.002). Maximal dose to the spinal cord was 30.6 Gy (SD 2.1), 33.1 Gy (SD 9.8) and 37.7 Gy (SD 2) for 3D, AP-PA and PA plans. CONCLUSION: 3D conformal treatment planning of lumbar vertebral metastases was significantly better in term of bowel and spinal cord exposure compared to AP-PA and PA techniques. The exposure of the kidneys in 3D plans, while greater than in the comparative plans, did not violate accepted dose-volume thresholds. |
format | Online Article Text |
id | pubmed-3599142 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35991422013-03-17 The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication Soyfer, Viacheslav Corn, Benjamin W Shtraus, Natan Schifter, Dan Tempelhof, Haim Radiat Oncol Methodology BACKGROUND: To evaluate the effect of the 3D radiation field design on normal tissues compared with commonly used appositional fields in patients with lumbar spine metastases. METHODS AND MATERIALS: Ten comparative treatment plans for radiation of lumbar spine metastases were compared for posterior and anterior- posterior fields with 3D plans. RESULTS: The PTV coverage in all comparative plans was similar. V 15 of the bowel in 3D, AP-PA and PA plans was 6.7 Gy (SD 6.47), 39.8 Gy (SD 11.4) and 37.3 Gy (SD15.7), respectively (p < 0.0001). The mean dose to both kidneys was 9.6 Gy (SD 4.8), 4.1 Gy (SD 3.9) and 4.6 Gy (SD 4.4) for appropriate plans (p = 0.002). Maximal dose to the spinal cord was 30.6 Gy (SD 2.1), 33.1 Gy (SD 9.8) and 37.7 Gy (SD 2) for 3D, AP-PA and PA plans. CONCLUSION: 3D conformal treatment planning of lumbar vertebral metastases was significantly better in term of bowel and spinal cord exposure compared to AP-PA and PA techniques. The exposure of the kidneys in 3D plans, while greater than in the comparative plans, did not violate accepted dose-volume thresholds. BioMed Central 2013-02-12 /pmc/articles/PMC3599142/ /pubmed/23398716 http://dx.doi.org/10.1186/1748-717X-8-34 Text en Copyright ©2013 Soyfer et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Methodology Soyfer, Viacheslav Corn, Benjamin W Shtraus, Natan Schifter, Dan Tempelhof, Haim The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title | The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title_full | The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title_fullStr | The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title_full_unstemmed | The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title_short | The advantage of 3D conformal treatment of lumbar spine metastases in comparison to traditional PA or AP-PA techniques: restoring an intermediate niche of therapeutic sophistication |
title_sort | advantage of 3d conformal treatment of lumbar spine metastases in comparison to traditional pa or ap-pa techniques: restoring an intermediate niche of therapeutic sophistication |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599142/ https://www.ncbi.nlm.nih.gov/pubmed/23398716 http://dx.doi.org/10.1186/1748-717X-8-34 |
work_keys_str_mv | AT soyferviacheslav theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT cornbenjaminw theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT shtrausnatan theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT schifterdan theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT tempelhofhaim theadvantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT soyferviacheslav advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT cornbenjaminw advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT shtrausnatan advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT schifterdan advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication AT tempelhofhaim advantageof3dconformaltreatmentoflumbarspinemetastasesincomparisontotraditionalpaorappatechniquesrestoringanintermediatenicheoftherapeuticsophistication |