Cargando…

Optimization of selective stimulation parameters for multi-contact electrodes

BACKGROUND: Multi-contact stimulating electrodes are gaining acceptance as a means for interfacing with the peripheral nervous system. These electrodes can potentially activate many independent populations of motor units within a single peripheral nerve, but quantifying their recruitment properties...

Descripción completa

Detalles Bibliográficos
Autores principales: Fisher, Lee E, Tyler, Dustin J, Triolo, Ronald J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599334/
https://www.ncbi.nlm.nih.gov/pubmed/23442372
http://dx.doi.org/10.1186/1743-0003-10-25
_version_ 1782262939706720256
author Fisher, Lee E
Tyler, Dustin J
Triolo, Ronald J
author_facet Fisher, Lee E
Tyler, Dustin J
Triolo, Ronald J
author_sort Fisher, Lee E
collection PubMed
description BACKGROUND: Multi-contact stimulating electrodes are gaining acceptance as a means for interfacing with the peripheral nervous system. These electrodes can potentially activate many independent populations of motor units within a single peripheral nerve, but quantifying their recruitment properties and the overlap in stimulation between contacts is difficult and time consuming. Further, current methods for quantifying overlap between contacts are ambiguous and can lead to suboptimal selective stimulation parameters. This study describes a novel method for optimizing stimulation parameters for multi-contact peripheral stimulating electrodes to produce strong, selective muscle contractions. The method is tested with four-contact spiral nerve-cuff electrodes implanted on bilateral femoral nerves of two individuals with spinal cord injury, but it is designed to be extendable to other electrode technologies with higher densities of contacts. METHODS: To optimize selective stimulation parameters for multi-contact electrodes, first, recruitment and overlap are characterized for all contacts within an electrode. Recruitment is measured with the twitch response to single stimulus pulses, and overlap between pairs of contacts is quantified by the deviation in their combined response from linear addition of individual responses. Simple mathematical models are fit to recruitment and overlap data, and a cost function is defined to maximize recruitment and minimize overlap between all contacts. RESULTS: Results are presented for four-contact nerve-cuff electrodes stimulating bilateral femoral nerves of two human subjects with spinal cord injury. Knee extension moments between 11.6 and 43.2 Nm were achieved with selective stimulation through multiple contacts of each nerve-cuff with less than 10% overlap between pairs of contacts. The overlap in stimulation measured in response to selective stimulation parameters was stable at multiple repeated time points after implantation. CONCLUSIONS: These results suggest that the method described here can provide an automated means of determining stimulus parameters to achieve strong muscle contractions via selective stimulation through multi-contact peripheral nerve electrodes.
format Online
Article
Text
id pubmed-3599334
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35993342013-03-25 Optimization of selective stimulation parameters for multi-contact electrodes Fisher, Lee E Tyler, Dustin J Triolo, Ronald J J Neuroeng Rehabil Methodology BACKGROUND: Multi-contact stimulating electrodes are gaining acceptance as a means for interfacing with the peripheral nervous system. These electrodes can potentially activate many independent populations of motor units within a single peripheral nerve, but quantifying their recruitment properties and the overlap in stimulation between contacts is difficult and time consuming. Further, current methods for quantifying overlap between contacts are ambiguous and can lead to suboptimal selective stimulation parameters. This study describes a novel method for optimizing stimulation parameters for multi-contact peripheral stimulating electrodes to produce strong, selective muscle contractions. The method is tested with four-contact spiral nerve-cuff electrodes implanted on bilateral femoral nerves of two individuals with spinal cord injury, but it is designed to be extendable to other electrode technologies with higher densities of contacts. METHODS: To optimize selective stimulation parameters for multi-contact electrodes, first, recruitment and overlap are characterized for all contacts within an electrode. Recruitment is measured with the twitch response to single stimulus pulses, and overlap between pairs of contacts is quantified by the deviation in their combined response from linear addition of individual responses. Simple mathematical models are fit to recruitment and overlap data, and a cost function is defined to maximize recruitment and minimize overlap between all contacts. RESULTS: Results are presented for four-contact nerve-cuff electrodes stimulating bilateral femoral nerves of two human subjects with spinal cord injury. Knee extension moments between 11.6 and 43.2 Nm were achieved with selective stimulation through multiple contacts of each nerve-cuff with less than 10% overlap between pairs of contacts. The overlap in stimulation measured in response to selective stimulation parameters was stable at multiple repeated time points after implantation. CONCLUSIONS: These results suggest that the method described here can provide an automated means of determining stimulus parameters to achieve strong muscle contractions via selective stimulation through multi-contact peripheral nerve electrodes. BioMed Central 2013-02-27 /pmc/articles/PMC3599334/ /pubmed/23442372 http://dx.doi.org/10.1186/1743-0003-10-25 Text en Copyright ©2013 Fisher et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Fisher, Lee E
Tyler, Dustin J
Triolo, Ronald J
Optimization of selective stimulation parameters for multi-contact electrodes
title Optimization of selective stimulation parameters for multi-contact electrodes
title_full Optimization of selective stimulation parameters for multi-contact electrodes
title_fullStr Optimization of selective stimulation parameters for multi-contact electrodes
title_full_unstemmed Optimization of selective stimulation parameters for multi-contact electrodes
title_short Optimization of selective stimulation parameters for multi-contact electrodes
title_sort optimization of selective stimulation parameters for multi-contact electrodes
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599334/
https://www.ncbi.nlm.nih.gov/pubmed/23442372
http://dx.doi.org/10.1186/1743-0003-10-25
work_keys_str_mv AT fisherleee optimizationofselectivestimulationparametersformulticontactelectrodes
AT tylerdustinj optimizationofselectivestimulationparametersformulticontactelectrodes
AT trioloronaldj optimizationofselectivestimulationparametersformulticontactelectrodes