Cargando…

Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagler, Michael, Bachmann, Lucas M, Alberio, Lorenzo, Angelillo-Scherrer, Anne, Asmis, Lars M, Korte, Wolfgang, Mendez, Adriana, Reber, Guido, Stricker, Hans, Tsakiris, Dimitrios A, Wuillemin, Walter A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599351/
https://www.ncbi.nlm.nih.gov/pubmed/23496906
http://dx.doi.org/10.1186/1477-9560-11-6
_version_ 1782262943610568704
author Nagler, Michael
Bachmann, Lucas M
Alberio, Lorenzo
Angelillo-Scherrer, Anne
Asmis, Lars M
Korte, Wolfgang
Mendez, Adriana
Reber, Guido
Stricker, Hans
Tsakiris, Dimitrios A
Wuillemin, Walter A
author_facet Nagler, Michael
Bachmann, Lucas M
Alberio, Lorenzo
Angelillo-Scherrer, Anne
Asmis, Lars M
Korte, Wolfgang
Mendez, Adriana
Reber, Guido
Stricker, Hans
Tsakiris, Dimitrios A
Wuillemin, Walter A
author_sort Nagler, Michael
collection PubMed
description BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
format Online
Article
Text
id pubmed-3599351
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35993512013-03-17 Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study Nagler, Michael Bachmann, Lucas M Alberio, Lorenzo Angelillo-Scherrer, Anne Asmis, Lars M Korte, Wolfgang Mendez, Adriana Reber, Guido Stricker, Hans Tsakiris, Dimitrios A Wuillemin, Walter A Thromb J Original Clinical Investigation BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors. BioMed Central 2013-03-07 /pmc/articles/PMC3599351/ /pubmed/23496906 http://dx.doi.org/10.1186/1477-9560-11-6 Text en Copyright ©2013 Nagler et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Clinical Investigation
Nagler, Michael
Bachmann, Lucas M
Alberio, Lorenzo
Angelillo-Scherrer, Anne
Asmis, Lars M
Korte, Wolfgang
Mendez, Adriana
Reber, Guido
Stricker, Hans
Tsakiris, Dimitrios A
Wuillemin, Walter A
Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title_full Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title_fullStr Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title_full_unstemmed Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title_short Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
title_sort variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
topic Original Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599351/
https://www.ncbi.nlm.nih.gov/pubmed/23496906
http://dx.doi.org/10.1186/1477-9560-11-6
work_keys_str_mv AT naglermichael variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT bachmannlucasm variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT alberiolorenzo variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT angelilloscherreranne variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT asmislarsm variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT kortewolfgang variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT mendezadriana variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT reberguido variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT strickerhans variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT tsakirisdimitriosa variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy
AT wuilleminwaltera variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy