Cargando…
Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when perfo...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599351/ https://www.ncbi.nlm.nih.gov/pubmed/23496906 http://dx.doi.org/10.1186/1477-9560-11-6 |
_version_ | 1782262943610568704 |
---|---|
author | Nagler, Michael Bachmann, Lucas M Alberio, Lorenzo Angelillo-Scherrer, Anne Asmis, Lars M Korte, Wolfgang Mendez, Adriana Reber, Guido Stricker, Hans Tsakiris, Dimitrios A Wuillemin, Walter A |
author_facet | Nagler, Michael Bachmann, Lucas M Alberio, Lorenzo Angelillo-Scherrer, Anne Asmis, Lars M Korte, Wolfgang Mendez, Adriana Reber, Guido Stricker, Hans Tsakiris, Dimitrios A Wuillemin, Walter A |
author_sort | Nagler, Michael |
collection | PubMed |
description | BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors. |
format | Online Article Text |
id | pubmed-3599351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-35993512013-03-17 Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study Nagler, Michael Bachmann, Lucas M Alberio, Lorenzo Angelillo-Scherrer, Anne Asmis, Lars M Korte, Wolfgang Mendez, Adriana Reber, Guido Stricker, Hans Tsakiris, Dimitrios A Wuillemin, Walter A Thromb J Original Clinical Investigation BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC’s ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors. BioMed Central 2013-03-07 /pmc/articles/PMC3599351/ /pubmed/23496906 http://dx.doi.org/10.1186/1477-9560-11-6 Text en Copyright ©2013 Nagler et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Clinical Investigation Nagler, Michael Bachmann, Lucas M Alberio, Lorenzo Angelillo-Scherrer, Anne Asmis, Lars M Korte, Wolfgang Mendez, Adriana Reber, Guido Stricker, Hans Tsakiris, Dimitrios A Wuillemin, Walter A Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title | Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title_full | Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title_fullStr | Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title_full_unstemmed | Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title_short | Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
title_sort | variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study |
topic | Original Clinical Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599351/ https://www.ncbi.nlm.nih.gov/pubmed/23496906 http://dx.doi.org/10.1186/1477-9560-11-6 |
work_keys_str_mv | AT naglermichael variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT bachmannlucasm variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT alberiolorenzo variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT angelilloscherreranne variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT asmislarsm variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT kortewolfgang variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT mendezadriana variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT reberguido variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT strickerhans variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT tsakirisdimitriosa variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy AT wuilleminwaltera variabilitybetweenlaboratoriesperformingcoagulationtestswithidenticalplatformsanationwideevaluationstudy |