Cargando…

Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time

BACKGROUND: Generation-3 (Gen-3) biosensors and advanced enzyme biofuel cells will benefit from direct electron transfer to oxidoreductases facilitated by single-walled carbon nanotubes (SWNTs). METHODS: Supramolecular conjugates of SWNT-glucose oxidase (GOx-SWNT) were produced via ultrasonic proces...

Descripción completa

Detalles Bibliográficos
Autores principales: Karunwi, Olukayode, Guiseppi-Elie, Anthony
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599492/
https://www.ncbi.nlm.nih.gov/pubmed/23425592
http://dx.doi.org/10.1186/1477-3155-11-6
_version_ 1782262975473647616
author Karunwi, Olukayode
Guiseppi-Elie, Anthony
author_facet Karunwi, Olukayode
Guiseppi-Elie, Anthony
author_sort Karunwi, Olukayode
collection PubMed
description BACKGROUND: Generation-3 (Gen-3) biosensors and advanced enzyme biofuel cells will benefit from direct electron transfer to oxidoreductases facilitated by single-walled carbon nanotubes (SWNTs). METHODS: Supramolecular conjugates of SWNT-glucose oxidase (GOx-SWNT) were produced via ultrasonic processing. Using a Plackett-Burman experimental design to investigate the process of tip ultrasonication (23 kHz), conjugate formation was investigated as a function of ultrasonication times (0, 5, 60 min) and functionalized SWNTs of various tube lengths (SWNT-X-L), (X = −OH or -COOH and L = 3.0 μm, 7.5 μm). RESULTS: Enzyme activity (K(M), k(cat), k(cat)/K(M), v(max) and n (the Hill parameter)) of pGOx (pristine), sGOx (sonicated) and GOx-SWNT-X-L revealed that sonication of any duration increased both K(M) and k(cat) of GOx but did not change k(cat)/K(M). Functionalized tubes had the most dramatic effect, reducing both K(M) and k(cat) and reducing k(cat)/K(M). UV–vis spectra over the range of 300 to 550 nm of native enzyme-bound FAD (λ(max) at 381 and 452 nm) or the blue-shifted solvated FAD of the denatured enzyme (λ(max) at 377 and 448 nm) revealed that ultrasonication up to 60 minutes had no influence on spectral characteristics of FAD but that the longer SWNTs caused some partial denaturation leading to egress of FAD. Circular dichroism spectral analysis of the 2° structure showed that sonication of any duration caused enrichment in the α-helical content at the sacrifice of the unordered sequences in GOx while the presence of SWNTs, regardless of length and/or functionality, reduced the β-sheet content of pristine GOx. Surface profiling by white light interferometry revealed that ultrasonication produced some aggregation of GOx and that GOx effectively debundled the SWNT. CONCLUSIONS: Supramolecular conjugates formed from shorter, -OH functionalized SWNTs using longer sonication times (60 min) gave the most favored combination for forming bioactive conjugates.
format Online
Article
Text
id pubmed-3599492
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35994922013-03-23 Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time Karunwi, Olukayode Guiseppi-Elie, Anthony J Nanobiotechnology Research BACKGROUND: Generation-3 (Gen-3) biosensors and advanced enzyme biofuel cells will benefit from direct electron transfer to oxidoreductases facilitated by single-walled carbon nanotubes (SWNTs). METHODS: Supramolecular conjugates of SWNT-glucose oxidase (GOx-SWNT) were produced via ultrasonic processing. Using a Plackett-Burman experimental design to investigate the process of tip ultrasonication (23 kHz), conjugate formation was investigated as a function of ultrasonication times (0, 5, 60 min) and functionalized SWNTs of various tube lengths (SWNT-X-L), (X = −OH or -COOH and L = 3.0 μm, 7.5 μm). RESULTS: Enzyme activity (K(M), k(cat), k(cat)/K(M), v(max) and n (the Hill parameter)) of pGOx (pristine), sGOx (sonicated) and GOx-SWNT-X-L revealed that sonication of any duration increased both K(M) and k(cat) of GOx but did not change k(cat)/K(M). Functionalized tubes had the most dramatic effect, reducing both K(M) and k(cat) and reducing k(cat)/K(M). UV–vis spectra over the range of 300 to 550 nm of native enzyme-bound FAD (λ(max) at 381 and 452 nm) or the blue-shifted solvated FAD of the denatured enzyme (λ(max) at 377 and 448 nm) revealed that ultrasonication up to 60 minutes had no influence on spectral characteristics of FAD but that the longer SWNTs caused some partial denaturation leading to egress of FAD. Circular dichroism spectral analysis of the 2° structure showed that sonication of any duration caused enrichment in the α-helical content at the sacrifice of the unordered sequences in GOx while the presence of SWNTs, regardless of length and/or functionality, reduced the β-sheet content of pristine GOx. Surface profiling by white light interferometry revealed that ultrasonication produced some aggregation of GOx and that GOx effectively debundled the SWNT. CONCLUSIONS: Supramolecular conjugates formed from shorter, -OH functionalized SWNTs using longer sonication times (60 min) gave the most favored combination for forming bioactive conjugates. BioMed Central 2013-02-20 /pmc/articles/PMC3599492/ /pubmed/23425592 http://dx.doi.org/10.1186/1477-3155-11-6 Text en Copyright ©2013 Karunwi and Guiseppi-Elie; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Karunwi, Olukayode
Guiseppi-Elie, Anthony
Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title_full Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title_fullStr Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title_full_unstemmed Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title_short Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
title_sort supramolecular glucose oxidase-swnt conjugates formed by ultrasonication: effect of tube length, functionalization and processing time
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3599492/
https://www.ncbi.nlm.nih.gov/pubmed/23425592
http://dx.doi.org/10.1186/1477-3155-11-6
work_keys_str_mv AT karunwiolukayode supramolecularglucoseoxidaseswntconjugatesformedbyultrasonicationeffectoftubelengthfunctionalizationandprocessingtime
AT guiseppielieanthony supramolecularglucoseoxidaseswntconjugatesformedbyultrasonicationeffectoftubelengthfunctionalizationandprocessingtime