Cargando…
Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty
The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS pr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Interventional Neuroradiology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3601282/ https://www.ncbi.nlm.nih.gov/pubmed/23515706 http://dx.doi.org/10.5469/neuroint.2013.8.1.52 |
_version_ | 1782475748757471232 |
---|---|
author | Kim, Mun Chul Bennett, Shelby Farb, Richard Croul, Sydney Lee, Seon-Kyu |
author_facet | Kim, Mun Chul Bennett, Shelby Farb, Richard Croul, Sydney Lee, Seon-Kyu |
author_sort | Kim, Mun Chul |
collection | PubMed |
description | The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS procedure. Immediate after stent deployment, the patient showed abrupt neurological deterioration with 12 × 3 mm sized macro-embolus which was caught by the embolus protection device (EPD). Retrieval of the macro-embolus was performed safely and the patient recovered to pre-procedure status. Macro-embolus can be resulted during the CAS. The EPD can capture the macro-embolus and safe removal is technically feasible. |
format | Online Article Text |
id | pubmed-3601282 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Korean Society of Interventional Neuroradiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-36012822013-03-20 Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty Kim, Mun Chul Bennett, Shelby Farb, Richard Croul, Sydney Lee, Seon-Kyu Neurointervention Case Report The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS procedure. Immediate after stent deployment, the patient showed abrupt neurological deterioration with 12 × 3 mm sized macro-embolus which was caught by the embolus protection device (EPD). Retrieval of the macro-embolus was performed safely and the patient recovered to pre-procedure status. Macro-embolus can be resulted during the CAS. The EPD can capture the macro-embolus and safe removal is technically feasible. Korean Society of Interventional Neuroradiology 2013-02 2013-02-28 /pmc/articles/PMC3601282/ /pubmed/23515706 http://dx.doi.org/10.5469/neuroint.2013.8.1.52 Text en Copyright © 2013 Korean Society of Interventional Neuroradiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kim, Mun Chul Bennett, Shelby Farb, Richard Croul, Sydney Lee, Seon-Kyu Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title | Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title_full | Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title_fullStr | Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title_full_unstemmed | Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title_short | Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty |
title_sort | captured macro-embolus of fractured atheromatous plaque by the embolic protection device during carotid stent assisted angioplasty |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3601282/ https://www.ncbi.nlm.nih.gov/pubmed/23515706 http://dx.doi.org/10.5469/neuroint.2013.8.1.52 |
work_keys_str_mv | AT kimmunchul capturedmacroembolusoffracturedatheromatousplaquebytheembolicprotectiondeviceduringcarotidstentassistedangioplasty AT bennettshelby capturedmacroembolusoffracturedatheromatousplaquebytheembolicprotectiondeviceduringcarotidstentassistedangioplasty AT farbrichard capturedmacroembolusoffracturedatheromatousplaquebytheembolicprotectiondeviceduringcarotidstentassistedangioplasty AT croulsydney capturedmacroembolusoffracturedatheromatousplaquebytheembolicprotectiondeviceduringcarotidstentassistedangioplasty AT leeseonkyu capturedmacroembolusoffracturedatheromatousplaquebytheembolicprotectiondeviceduringcarotidstentassistedangioplasty |