Cargando…
A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 ×...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3603494/ https://www.ncbi.nlm.nih.gov/pubmed/23531643 http://dx.doi.org/10.4137/ACI.S11256 |
_version_ | 1782263693829996544 |
---|---|
author | Auvity, Sylvain Chiadmi, Fouad Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël |
author_facet | Auvity, Sylvain Chiadmi, Fouad Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël |
author_sort | Auvity, Sylvain |
collection | PubMed |
description | A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%–101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets. |
format | Online Article Text |
id | pubmed-3603494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-36034942013-03-25 A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets Auvity, Sylvain Chiadmi, Fouad Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël Anal Chem Insights Rapid Communication A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%–101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets. Libertas Academica 2013-03-11 /pmc/articles/PMC3603494/ /pubmed/23531643 http://dx.doi.org/10.4137/ACI.S11256 Text en © 2013 the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited. |
spellingShingle | Rapid Communication Auvity, Sylvain Chiadmi, Fouad Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title | A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title_full | A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title_fullStr | A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title_full_unstemmed | A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title_short | A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets |
title_sort | rapid stability-indicating rp-hplc method for the determination of betaxolol hydrochloride in pharmaceutical tablets |
topic | Rapid Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3603494/ https://www.ncbi.nlm.nih.gov/pubmed/23531643 http://dx.doi.org/10.4137/ACI.S11256 |
work_keys_str_mv | AT auvitysylvain arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT chiadmifouad arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT cisterninosalvatore arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT fontanjeaneudes arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT schlatterjoel arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT auvitysylvain rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT chiadmifouad rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT cisterninosalvatore rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT fontanjeaneudes rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets AT schlatterjoel rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets |