Cargando…

A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets

A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 ×...

Descripción completa

Detalles Bibliográficos
Autores principales: Auvity, Sylvain, Chiadmi, Fouad, Cisternino, Salvatore, Fontan, Jean-Eudes, Schlatter, Joël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Libertas Academica 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3603494/
https://www.ncbi.nlm.nih.gov/pubmed/23531643
http://dx.doi.org/10.4137/ACI.S11256
_version_ 1782263693829996544
author Auvity, Sylvain
Chiadmi, Fouad
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
author_facet Auvity, Sylvain
Chiadmi, Fouad
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
author_sort Auvity, Sylvain
collection PubMed
description A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%–101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets.
format Online
Article
Text
id pubmed-3603494
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Libertas Academica
record_format MEDLINE/PubMed
spelling pubmed-36034942013-03-25 A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets Auvity, Sylvain Chiadmi, Fouad Cisternino, Salvatore Fontan, Jean-Eudes Schlatter, Joël Anal Chem Insights Rapid Communication A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%–101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets. Libertas Academica 2013-03-11 /pmc/articles/PMC3603494/ /pubmed/23531643 http://dx.doi.org/10.4137/ACI.S11256 Text en © 2013 the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited.
spellingShingle Rapid Communication
Auvity, Sylvain
Chiadmi, Fouad
Cisternino, Salvatore
Fontan, Jean-Eudes
Schlatter, Joël
A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title_full A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title_fullStr A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title_full_unstemmed A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title_short A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
title_sort rapid stability-indicating rp-hplc method for the determination of betaxolol hydrochloride in pharmaceutical tablets
topic Rapid Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3603494/
https://www.ncbi.nlm.nih.gov/pubmed/23531643
http://dx.doi.org/10.4137/ACI.S11256
work_keys_str_mv AT auvitysylvain arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT chiadmifouad arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT cisterninosalvatore arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT fontanjeaneudes arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT schlatterjoel arapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT auvitysylvain rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT chiadmifouad rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT cisterninosalvatore rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT fontanjeaneudes rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets
AT schlatterjoel rapidstabilityindicatingrphplcmethodforthedeterminationofbetaxololhydrochlorideinpharmaceuticaltablets