Cargando…
Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans
Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3604103/ https://www.ncbi.nlm.nih.gov/pubmed/23527111 http://dx.doi.org/10.1371/journal.pone.0059130 |
_version_ | 1782263741527621632 |
---|---|
author | Rangel, Frits A. Maal, Thomas J. J. Bronkhorst, Ewald M. Breuning, K. Hero Schols, Jan G. J. H. Bergé, Stefaan J. Kuijpers-Jagtman, Anne Marie |
author_facet | Rangel, Frits A. Maal, Thomas J. J. Bronkhorst, Ewald M. Breuning, K. Hero Schols, Jan G. J. H. Bergé, Stefaan J. Kuijpers-Jagtman, Anne Marie |
author_sort | Rangel, Frits A. |
collection | PubMed |
description | Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. |
format | Online Article Text |
id | pubmed-3604103 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36041032013-03-22 Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans Rangel, Frits A. Maal, Thomas J. J. Bronkhorst, Ewald M. Breuning, K. Hero Schols, Jan G. J. H. Bergé, Stefaan J. Kuijpers-Jagtman, Anne Marie PLoS One Research Article Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. Public Library of Science 2013-03-20 /pmc/articles/PMC3604103/ /pubmed/23527111 http://dx.doi.org/10.1371/journal.pone.0059130 Text en © 2013 Rangel et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Rangel, Frits A. Maal, Thomas J. J. Bronkhorst, Ewald M. Breuning, K. Hero Schols, Jan G. J. H. Bergé, Stefaan J. Kuijpers-Jagtman, Anne Marie Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title | Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title_full | Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title_fullStr | Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title_full_unstemmed | Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title_short | Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans |
title_sort | accuracy and reliability of a novel method for fusion of digital dental casts and cone beam computed tomography scans |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3604103/ https://www.ncbi.nlm.nih.gov/pubmed/23527111 http://dx.doi.org/10.1371/journal.pone.0059130 |
work_keys_str_mv | AT rangelfritsa accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT maalthomasjj accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT bronkhorstewaldm accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT breuningkhero accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT scholsjangjh accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT bergestefaanj accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans AT kuijpersjagtmanannemarie accuracyandreliabilityofanovelmethodforfusionofdigitaldentalcastsandconebeamcomputedtomographyscans |