Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality
PURPOSE: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. MATERIALS AND METHODS: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phant...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3604374/ https://www.ncbi.nlm.nih.gov/pubmed/23526047 http://dx.doi.org/10.5624/isd.2013.43.1.7 |
_version_ | 1782263757546717184 |
---|---|
author | Choi, Da-Hye Choi, Bo-Ram Choi, Jin-Woo Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Choi, Soon-Chul Lee, Sam-Sun |
author_facet | Choi, Da-Hye Choi, Bo-Ram Choi, Jin-Woo Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Choi, Soon-Chul Lee, Sam-Sun |
author_sort | Choi, Da-Hye |
collection | PubMed |
description | PURPOSE: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. MATERIALS AND METHODS: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. RESULT: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. CONCLUSION: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them. |
format | Online Article Text |
id | pubmed-3604374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-36043742013-03-22 Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality Choi, Da-Hye Choi, Bo-Ram Choi, Jin-Woo Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Choi, Soon-Chul Lee, Sam-Sun Imaging Sci Dent Original Article PURPOSE: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. MATERIALS AND METHODS: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. RESULT: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. CONCLUSION: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them. Korean Academy of Oral and Maxillofacial Radiology 2013-03 2013-03-11 /pmc/articles/PMC3604374/ /pubmed/23526047 http://dx.doi.org/10.5624/isd.2013.43.1.7 Text en Copyright © 2013 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Choi, Da-Hye Choi, Bo-Ram Choi, Jin-Woo Huh, Kyung-Hoe Yi, Won-Jin Heo, Min-Suk Choi, Soon-Chul Lee, Sam-Sun Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title | Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title_full | Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title_fullStr | Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title_full_unstemmed | Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title_short | Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
title_sort | reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3604374/ https://www.ncbi.nlm.nih.gov/pubmed/23526047 http://dx.doi.org/10.5624/isd.2013.43.1.7 |
work_keys_str_mv | AT choidahye referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT choiboram referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT choijinwoo referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT huhkyunghoe referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT yiwonjin referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT heominsuk referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT choisoonchul referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality AT leesamsun referencelinepairvaluesofpanoramicradiographsusinganarchformphantomstandtoassessclinicalimagequality |