Cargando…

The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays

The assessment of nonviable haematopoietic cells by Annexin V staining method in flow cytometry has recently been published by Duggleby et al. Resulting in a better correlation with the observed colony formation in methylcellulose assays than the standard ISHAGE protocol, it presents a promising met...

Descripción completa

Detalles Bibliográficos
Autores principales: Radke, Teja Falk, Barbosa, David, Duggleby, Richard Charles, Saccardi, Riccardo, Querol, Sergio, Kögler, Gesine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3606789/
https://www.ncbi.nlm.nih.gov/pubmed/23533443
http://dx.doi.org/10.1155/2013/823912
_version_ 1782264056348934144
author Radke, Teja Falk
Barbosa, David
Duggleby, Richard Charles
Saccardi, Riccardo
Querol, Sergio
Kögler, Gesine
author_facet Radke, Teja Falk
Barbosa, David
Duggleby, Richard Charles
Saccardi, Riccardo
Querol, Sergio
Kögler, Gesine
author_sort Radke, Teja Falk
collection PubMed
description The assessment of nonviable haematopoietic cells by Annexin V staining method in flow cytometry has recently been published by Duggleby et al. Resulting in a better correlation with the observed colony formation in methylcellulose assays than the standard ISHAGE protocol, it presents a promising method to predict cord blood potency. Herein, we applied this method for examining the parameters during processing which potentially could affect cord blood viability. We could verify that the current standards regarding time and temperature are sufficient, since no significant difference was observed within 48 hours or in storage at 4°C up to 26°C. However, the addition of DMSO for cryopreservation alone leads to an inevitable increase in nonviable haematopoietic stem cells from initially 14.8% ± 4.3% to at least 30.6% ± 5.5%. Furthermore, CFU-assays with varied seeding density were performed in order to evaluate the applicability as a quantitative method. The results revealed that only in a narrow range reproducible clonogenic efficiency (ClonE) could be assessed, giving at least a semiquantitative estimation. We conclude that both Annexin V staining method and CFU-assays with defined seeding density are reliable means leading to a better prediction of the final potency. Especially Annexin V, due to its fast readout, is a practical tool for examining and optimising specific steps in processing, while CFU-assays add a functional confirmation.
format Online
Article
Text
id pubmed-3606789
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-36067892013-03-26 The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays Radke, Teja Falk Barbosa, David Duggleby, Richard Charles Saccardi, Riccardo Querol, Sergio Kögler, Gesine Stem Cells Int Research Article The assessment of nonviable haematopoietic cells by Annexin V staining method in flow cytometry has recently been published by Duggleby et al. Resulting in a better correlation with the observed colony formation in methylcellulose assays than the standard ISHAGE protocol, it presents a promising method to predict cord blood potency. Herein, we applied this method for examining the parameters during processing which potentially could affect cord blood viability. We could verify that the current standards regarding time and temperature are sufficient, since no significant difference was observed within 48 hours or in storage at 4°C up to 26°C. However, the addition of DMSO for cryopreservation alone leads to an inevitable increase in nonviable haematopoietic stem cells from initially 14.8% ± 4.3% to at least 30.6% ± 5.5%. Furthermore, CFU-assays with varied seeding density were performed in order to evaluate the applicability as a quantitative method. The results revealed that only in a narrow range reproducible clonogenic efficiency (ClonE) could be assessed, giving at least a semiquantitative estimation. We conclude that both Annexin V staining method and CFU-assays with defined seeding density are reliable means leading to a better prediction of the final potency. Especially Annexin V, due to its fast readout, is a practical tool for examining and optimising specific steps in processing, while CFU-assays add a functional confirmation. Hindawi Publishing Corporation 2013 2013-03-07 /pmc/articles/PMC3606789/ /pubmed/23533443 http://dx.doi.org/10.1155/2013/823912 Text en Copyright © 2013 Teja Falk Radke et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Radke, Teja Falk
Barbosa, David
Duggleby, Richard Charles
Saccardi, Riccardo
Querol, Sergio
Kögler, Gesine
The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title_full The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title_fullStr The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title_full_unstemmed The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title_short The Assessment of Parameters Affecting the Quality of Cord Blood by the Appliance of the Annexin V Staining Method and Correlation with CFU Assays
title_sort assessment of parameters affecting the quality of cord blood by the appliance of the annexin v staining method and correlation with cfu assays
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3606789/
https://www.ncbi.nlm.nih.gov/pubmed/23533443
http://dx.doi.org/10.1155/2013/823912
work_keys_str_mv AT radketejafalk theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT barbosadavid theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT dugglebyrichardcharles theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT saccardiriccardo theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT querolsergio theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT koglergesine theassessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT radketejafalk assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT barbosadavid assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT dugglebyrichardcharles assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT saccardiriccardo assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT querolsergio assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays
AT koglergesine assessmentofparametersaffectingthequalityofcordbloodbytheapplianceoftheannexinvstainingmethodandcorrelationwithcfuassays