MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout
Purpose. To evaluate the accuracy of the washout in the differential diagnosis between adenomas and nonadenomas and to compare the obtained results in delayed CT scans at 5, 10 and 15 minutes. Methods. Fifty patients with adrenal masses were prospectively evaluated. CT scans were performed by using...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3606796/ https://www.ncbi.nlm.nih.gov/pubmed/23533368 http://dx.doi.org/10.1155/2013/957680 |
_version_ | 1782264057950109696 |
---|---|
author | Angelelli, Giuseppe Mancini, Maria Elisabetta Moschetta, Marco Pedote, Pasquale Pignataro, Pasquale Scardapane, Arnaldo |
author_facet | Angelelli, Giuseppe Mancini, Maria Elisabetta Moschetta, Marco Pedote, Pasquale Pignataro, Pasquale Scardapane, Arnaldo |
author_sort | Angelelli, Giuseppe |
collection | PubMed |
description | Purpose. To evaluate the accuracy of the washout in the differential diagnosis between adenomas and nonadenomas and to compare the obtained results in delayed CT scans at 5, 10 and 15 minutes. Methods. Fifty patients with adrenal masses were prospectively evaluated. CT scans were performed by using a 320-row MDCT device, before and after injection of contrast material. In 25 cases, delayed scans were performed at 5′ and 10′ (group 1), while in the remaining 25, at 5′ and 15′ (group 2). Absolute and relative wash-out percentage values (APW and RPW) were calculated. Results. Differential diagnosis between adenomas and nonadenomas was obtained in 48/50 (96%) cases, with sensitivity, specificity, and accuracy values of 96%, 95%, and 96%, respectively. In group 1, APW and RPW values were, respectively, 69.8% and 67.2% at 5′ and 75.9% and 73.5% at 10′ for adenomas and 25.1% and 15.8% at 5′ and 33.5% and 20.5% at 10′ for nonadenomas. In group 2, APW and RPW values were 63% and 54.6% at 5′ and 73.8% and 65.5% at 15′ for adenomas and 22% and 12.5% at 5′ and 35.5% and 19.9% at 15′ for nonadenomas. Conclusions. The evaluation of the wash-out values in CT scans performed at 5′, 10′, and 15′ provides comparable diagnostic results. CT scans performed at 5′ are, therefore, to be preferred, since they reduce the examination time and patient discomfort. |
format | Online Article Text |
id | pubmed-3606796 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36067962013-03-26 MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout Angelelli, Giuseppe Mancini, Maria Elisabetta Moschetta, Marco Pedote, Pasquale Pignataro, Pasquale Scardapane, Arnaldo ScientificWorldJournal Clinical Study Purpose. To evaluate the accuracy of the washout in the differential diagnosis between adenomas and nonadenomas and to compare the obtained results in delayed CT scans at 5, 10 and 15 minutes. Methods. Fifty patients with adrenal masses were prospectively evaluated. CT scans were performed by using a 320-row MDCT device, before and after injection of contrast material. In 25 cases, delayed scans were performed at 5′ and 10′ (group 1), while in the remaining 25, at 5′ and 15′ (group 2). Absolute and relative wash-out percentage values (APW and RPW) were calculated. Results. Differential diagnosis between adenomas and nonadenomas was obtained in 48/50 (96%) cases, with sensitivity, specificity, and accuracy values of 96%, 95%, and 96%, respectively. In group 1, APW and RPW values were, respectively, 69.8% and 67.2% at 5′ and 75.9% and 73.5% at 10′ for adenomas and 25.1% and 15.8% at 5′ and 33.5% and 20.5% at 10′ for nonadenomas. In group 2, APW and RPW values were 63% and 54.6% at 5′ and 73.8% and 65.5% at 15′ for adenomas and 22% and 12.5% at 5′ and 35.5% and 19.9% at 15′ for nonadenomas. Conclusions. The evaluation of the wash-out values in CT scans performed at 5′, 10′, and 15′ provides comparable diagnostic results. CT scans performed at 5′ are, therefore, to be preferred, since they reduce the examination time and patient discomfort. Hindawi Publishing Corporation 2013-03-07 /pmc/articles/PMC3606796/ /pubmed/23533368 http://dx.doi.org/10.1155/2013/957680 Text en Copyright © 2013 Giuseppe Angelelli et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Angelelli, Giuseppe Mancini, Maria Elisabetta Moschetta, Marco Pedote, Pasquale Pignataro, Pasquale Scardapane, Arnaldo MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title | MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title_full | MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title_fullStr | MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title_full_unstemmed | MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title_short | MDCT in the Differentiation of Adrenal Masses: Comparison between Different Scan Delays for the Evaluation of Intralesional Washout |
title_sort | mdct in the differentiation of adrenal masses: comparison between different scan delays for the evaluation of intralesional washout |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3606796/ https://www.ncbi.nlm.nih.gov/pubmed/23533368 http://dx.doi.org/10.1155/2013/957680 |
work_keys_str_mv | AT angelelligiuseppe mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout AT mancinimariaelisabetta mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout AT moschettamarco mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout AT pedotepasquale mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout AT pignataropasquale mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout AT scardapanearnaldo mdctinthedifferentiationofadrenalmassescomparisonbetweendifferentscandelaysfortheevaluationofintralesionalwashout |