Cargando…
Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer
The present study is aimed at comparing the planning and delivery efficiency between three-dimensional conformal radiotherapy (3D-CRT), field-in-field, forward planned, intensity modulated radiotherapy (FIF-FP-IMRT), and inverse planned intensity modulated radiotherapy (IP-IMRT). Treatment plans of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607341/ https://www.ncbi.nlm.nih.gov/pubmed/23531607 http://dx.doi.org/10.4103/0971-6203.106601 |
_version_ | 1782264102695993344 |
---|---|
author | Al-Rahbi, Zakiya Salem Al Mandhari, Zahid Ravichandran, Ramamoorthy Al-Kindi, Fatma Davis, Cheriyathmanjiyil Anthony Bhasi, Saju Satyapal, Namrata Rajan, Balakrishnan |
author_facet | Al-Rahbi, Zakiya Salem Al Mandhari, Zahid Ravichandran, Ramamoorthy Al-Kindi, Fatma Davis, Cheriyathmanjiyil Anthony Bhasi, Saju Satyapal, Namrata Rajan, Balakrishnan |
author_sort | Al-Rahbi, Zakiya Salem |
collection | PubMed |
description | The present study is aimed at comparing the planning and delivery efficiency between three-dimensional conformal radiotherapy (3D-CRT), field-in-field, forward planned, intensity modulated radiotherapy (FIF-FP-IMRT), and inverse planned intensity modulated radiotherapy (IP-IMRT). Treatment plans of 20 patients with left-sided breast cancer, 10 post-mastectomy treated to a prescribed dose of 45 Gy to the chest wall in 20 fractions, and 10 post-breast-conserving surgery to a prescribed dose of 50 Gy to the whole breast in 25 fractions, with 3D-CRT were selected. The FiF-FP-IMRT plans were created by combining two open fields with three to four segments in two tangential beam directions. Eight different beam directions were chosen to create IP-IMRT plans and were inversely optimized. The homogeneity of dose to planning target volume (PTV) and the dose delivered to heart and contralateral breast were compared among the techniques in all the 20 patients. All the three radiotherapy techniques achieved comparable radiation dose delivery to PTV-95% of the prescribed dose covering > 95% of the breast PTV. The mean volume of PTV receiving 105% (V(105)) of the prescribed dose was 1.7% (range 0-6.8%) for IP-IMRT, 1.9% for FP-IMRT, and 3.7% for 3D-CRT. The homogeneity and conformity indices (HI and CI) were similar for 3D-CRT and FP-IMRT, whereas the IP-IMRT plans had better conformity index at the cost of less homogeneity. The 3D-CRT and FiF-FP-IMRT plans achieved similar sparing of critical organs. The low-dose volumes (V(5Gy)) in the heart and lungs were larger in IP-IMRT than in the other techniques. The value of the mean dose to the ipsilateral lung was higher for IP-IMRT than the values for with FiF-FP-IMRT and 3D-CRT. In the current study, the relative volume of contralateral breast receiving low doses (0.01, 0.6, 1, and 2Gy) was significantly lower for the FiF-FP-IMRT and 3D-CRT plans than for the IP-IMRT plan. Compared with 3D-CRT and IP-IMRT, FiF-FP-IMRT proved to be a simple and efficient planning technique for breast irradiation. It provided dosimetric advantages, significantly reducing the size of the hot spot and minimally improving the coverage of the target volume. In addition, it was felt that FiF-FP-IMRT required less planning time and easy field placements. |
format | Online Article Text |
id | pubmed-3607341 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-36073412013-03-26 Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer Al-Rahbi, Zakiya Salem Al Mandhari, Zahid Ravichandran, Ramamoorthy Al-Kindi, Fatma Davis, Cheriyathmanjiyil Anthony Bhasi, Saju Satyapal, Namrata Rajan, Balakrishnan J Med Phys Original Article The present study is aimed at comparing the planning and delivery efficiency between three-dimensional conformal radiotherapy (3D-CRT), field-in-field, forward planned, intensity modulated radiotherapy (FIF-FP-IMRT), and inverse planned intensity modulated radiotherapy (IP-IMRT). Treatment plans of 20 patients with left-sided breast cancer, 10 post-mastectomy treated to a prescribed dose of 45 Gy to the chest wall in 20 fractions, and 10 post-breast-conserving surgery to a prescribed dose of 50 Gy to the whole breast in 25 fractions, with 3D-CRT were selected. The FiF-FP-IMRT plans were created by combining two open fields with three to four segments in two tangential beam directions. Eight different beam directions were chosen to create IP-IMRT plans and were inversely optimized. The homogeneity of dose to planning target volume (PTV) and the dose delivered to heart and contralateral breast were compared among the techniques in all the 20 patients. All the three radiotherapy techniques achieved comparable radiation dose delivery to PTV-95% of the prescribed dose covering > 95% of the breast PTV. The mean volume of PTV receiving 105% (V(105)) of the prescribed dose was 1.7% (range 0-6.8%) for IP-IMRT, 1.9% for FP-IMRT, and 3.7% for 3D-CRT. The homogeneity and conformity indices (HI and CI) were similar for 3D-CRT and FP-IMRT, whereas the IP-IMRT plans had better conformity index at the cost of less homogeneity. The 3D-CRT and FiF-FP-IMRT plans achieved similar sparing of critical organs. The low-dose volumes (V(5Gy)) in the heart and lungs were larger in IP-IMRT than in the other techniques. The value of the mean dose to the ipsilateral lung was higher for IP-IMRT than the values for with FiF-FP-IMRT and 3D-CRT. In the current study, the relative volume of contralateral breast receiving low doses (0.01, 0.6, 1, and 2Gy) was significantly lower for the FiF-FP-IMRT and 3D-CRT plans than for the IP-IMRT plan. Compared with 3D-CRT and IP-IMRT, FiF-FP-IMRT proved to be a simple and efficient planning technique for breast irradiation. It provided dosimetric advantages, significantly reducing the size of the hot spot and minimally improving the coverage of the target volume. In addition, it was felt that FiF-FP-IMRT required less planning time and easy field placements. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3607341/ /pubmed/23531607 http://dx.doi.org/10.4103/0971-6203.106601 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Al-Rahbi, Zakiya Salem Al Mandhari, Zahid Ravichandran, Ramamoorthy Al-Kindi, Fatma Davis, Cheriyathmanjiyil Anthony Bhasi, Saju Satyapal, Namrata Rajan, Balakrishnan Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title | Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title_full | Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title_fullStr | Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title_full_unstemmed | Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title_short | Dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (FIF) forward plans in the treatment of breast cancer |
title_sort | dosimetric comparison of intensity modulated radiotherapy isocentric field plans and field in field (fif) forward plans in the treatment of breast cancer |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607341/ https://www.ncbi.nlm.nih.gov/pubmed/23531607 http://dx.doi.org/10.4103/0971-6203.106601 |
work_keys_str_mv | AT alrahbizakiyasalem dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT almandharizahid dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT ravichandranramamoorthy dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT alkindifatma dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT davischeriyathmanjiyilanthony dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT bhasisaju dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT satyapalnamrata dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer AT rajanbalakrishnan dosimetriccomparisonofintensitymodulatedradiotherapyisocentricfieldplansandfieldinfieldfifforwardplansinthetreatmentofbreastcancer |