Cargando…
Computational method for calculating fluorescence intensities within three-dimensional structures in cells
The use of fluorescence microscopy is central to cell biology in general, and essential to many fields (e.g., membrane traffic) that rely upon it to identify cellular locations of molecules under study and the extent to which they co-localize with others. Rigorous localization or co-localization dat...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Landes Bioscience
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607619/ https://www.ncbi.nlm.nih.gov/pubmed/23538475 http://dx.doi.org/10.4161/cl.23150 |
_version_ | 1782264124687777792 |
---|---|
author | Caster, Amanda H. Kahn, Richard A. |
author_facet | Caster, Amanda H. Kahn, Richard A. |
author_sort | Caster, Amanda H. |
collection | PubMed |
description | The use of fluorescence microscopy is central to cell biology in general, and essential to many fields (e.g., membrane traffic) that rely upon it to identify cellular locations of molecules under study and the extent to which they co-localize with others. Rigorous localization or co-localization data require quantitative image analyses that can vary widely between fields and laboratories. While most published data use two-dimensional images, there is an increasing appreciation for the advantages of collecting three-dimensional data sets. These include the ability to evaluate the entire cell and avoidance of focal plane bias. This is particularly important when imaging and quantifying changes in organelles with irregular borders and which vary in appearance between cells in a population, e.g., the Golgi. We describe a method developed for quantifying changes in signal intensity of one protein within any three-dimensional structure, defined by the presence of a different marker. We use as examples of this method the quantification of adaptor recruitment to transmembrane protein cargos at the Golgi though it can be directly applied to any site in the cell. Together, these advantages facilitate rigorous statistical testing of differences between conditions, despite variations in organelle structure, and we believe that this method of quantification of fluorescence data can be productively applied to a wide array of experimental questions. |
format | Online Article Text |
id | pubmed-3607619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Landes Bioscience |
record_format | MEDLINE/PubMed |
spelling | pubmed-36076192013-03-27 Computational method for calculating fluorescence intensities within three-dimensional structures in cells Caster, Amanda H. Kahn, Richard A. Cell Logist Methods and Technologies The use of fluorescence microscopy is central to cell biology in general, and essential to many fields (e.g., membrane traffic) that rely upon it to identify cellular locations of molecules under study and the extent to which they co-localize with others. Rigorous localization or co-localization data require quantitative image analyses that can vary widely between fields and laboratories. While most published data use two-dimensional images, there is an increasing appreciation for the advantages of collecting three-dimensional data sets. These include the ability to evaluate the entire cell and avoidance of focal plane bias. This is particularly important when imaging and quantifying changes in organelles with irregular borders and which vary in appearance between cells in a population, e.g., the Golgi. We describe a method developed for quantifying changes in signal intensity of one protein within any three-dimensional structure, defined by the presence of a different marker. We use as examples of this method the quantification of adaptor recruitment to transmembrane protein cargos at the Golgi though it can be directly applied to any site in the cell. Together, these advantages facilitate rigorous statistical testing of differences between conditions, despite variations in organelle structure, and we believe that this method of quantification of fluorescence data can be productively applied to a wide array of experimental questions. Landes Bioscience 2012-10-01 /pmc/articles/PMC3607619/ /pubmed/23538475 http://dx.doi.org/10.4161/cl.23150 Text en Copyright © 2012 Landes Bioscience http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited. |
spellingShingle | Methods and Technologies Caster, Amanda H. Kahn, Richard A. Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title | Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title_full | Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title_fullStr | Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title_full_unstemmed | Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title_short | Computational method for calculating fluorescence intensities within three-dimensional structures in cells |
title_sort | computational method for calculating fluorescence intensities within three-dimensional structures in cells |
topic | Methods and Technologies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607619/ https://www.ncbi.nlm.nih.gov/pubmed/23538475 http://dx.doi.org/10.4161/cl.23150 |
work_keys_str_mv | AT casteramandah computationalmethodforcalculatingfluorescenceintensitieswithinthreedimensionalstructuresincells AT kahnricharda computationalmethodforcalculatingfluorescenceintensitieswithinthreedimensionalstructuresincells |