Cargando…

ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software

BACKGROUND: Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-spee...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Claire M, Djakow, Jana, Free, Robert C, Djakow, Petr, Lonnen, Rana, Williams, Gwyneth, Pohunek, Petr, Hirst, Robert A, Easton, Andrew J, Andrew, Peter W, O’Callaghan, Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607980/
https://www.ncbi.nlm.nih.gov/pubmed/23351276
http://dx.doi.org/10.1186/2046-2530-1-14
_version_ 1782264170810441728
author Smith, Claire M
Djakow, Jana
Free, Robert C
Djakow, Petr
Lonnen, Rana
Williams, Gwyneth
Pohunek, Petr
Hirst, Robert A
Easton, Andrew J
Andrew, Peter W
O’Callaghan, Christopher
author_facet Smith, Claire M
Djakow, Jana
Free, Robert C
Djakow, Petr
Lonnen, Rana
Williams, Gwyneth
Pohunek, Petr
Hirst, Robert A
Easton, Andrew J
Andrew, Peter W
O’Callaghan, Christopher
author_sort Smith, Claire M
collection PubMed
description BACKGROUND: Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digital video (AVI) files that runs on open-source software (ImageJ) coupled to Microsoft Excel, and to validate this by comparison to the direct measuring high-speed video recordings of respiratory and ependymal cilia. These models allowed comparison to cilia beating between 3 and 52 Hz. METHODS: Digital video files of motile ciliated ependymal (frequency range 34 to 52 Hz) and respiratory epithelial cells (frequency 3 to 18 Hz) were captured using a high-speed digital video recorder. To cover the range above between 18 and 37 Hz the frequency of ependymal cilia were slowed by the addition of the pneumococcal toxin pneumolysin. Measurements made directly by timing a given number of individual ciliary beat cycles were compared with those obtained using the automated ciliaFA system. RESULTS: The overall mean difference (± SD) between the ciliaFA and direct measurement high-speed digital imaging methods was −0.05 ± 1.25 Hz, the correlation coefficient was shown to be 0.991 and the Bland-Altman limits of agreement were from −1.99 to 1.49 Hz for respiratory and from −2.55 to 3.25 Hz for ependymal cilia. CONCLUSIONS: A plugin for ImageJ was developed that extracts pixel intensities and performs fast Fourier transformation (FFT) using Microsoft Excel. The ciliaFA software allowed automated, high throughput measurement of respiratory and ependymal ciliary beat frequency (range 3 to 52 Hz) and avoids operator error due to selection bias. We have included free access to the ciliaFA plugin and installation instructions in Additional file 1 accompanying this manuscript that other researchers may use.
format Online
Article
Text
id pubmed-3607980
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36079802013-04-01 ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software Smith, Claire M Djakow, Jana Free, Robert C Djakow, Petr Lonnen, Rana Williams, Gwyneth Pohunek, Petr Hirst, Robert A Easton, Andrew J Andrew, Peter W O’Callaghan, Christopher Cilia Methodology BACKGROUND: Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digital video (AVI) files that runs on open-source software (ImageJ) coupled to Microsoft Excel, and to validate this by comparison to the direct measuring high-speed video recordings of respiratory and ependymal cilia. These models allowed comparison to cilia beating between 3 and 52 Hz. METHODS: Digital video files of motile ciliated ependymal (frequency range 34 to 52 Hz) and respiratory epithelial cells (frequency 3 to 18 Hz) were captured using a high-speed digital video recorder. To cover the range above between 18 and 37 Hz the frequency of ependymal cilia were slowed by the addition of the pneumococcal toxin pneumolysin. Measurements made directly by timing a given number of individual ciliary beat cycles were compared with those obtained using the automated ciliaFA system. RESULTS: The overall mean difference (± SD) between the ciliaFA and direct measurement high-speed digital imaging methods was −0.05 ± 1.25 Hz, the correlation coefficient was shown to be 0.991 and the Bland-Altman limits of agreement were from −1.99 to 1.49 Hz for respiratory and from −2.55 to 3.25 Hz for ependymal cilia. CONCLUSIONS: A plugin for ImageJ was developed that extracts pixel intensities and performs fast Fourier transformation (FFT) using Microsoft Excel. The ciliaFA software allowed automated, high throughput measurement of respiratory and ependymal ciliary beat frequency (range 3 to 52 Hz) and avoids operator error due to selection bias. We have included free access to the ciliaFA plugin and installation instructions in Additional file 1 accompanying this manuscript that other researchers may use. BioMed Central 2012-08-01 /pmc/articles/PMC3607980/ /pubmed/23351276 http://dx.doi.org/10.1186/2046-2530-1-14 Text en Copyright ©2012 Smith et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Smith, Claire M
Djakow, Jana
Free, Robert C
Djakow, Petr
Lonnen, Rana
Williams, Gwyneth
Pohunek, Petr
Hirst, Robert A
Easton, Andrew J
Andrew, Peter W
O’Callaghan, Christopher
ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title_full ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title_fullStr ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title_full_unstemmed ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title_short ciliaFA: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
title_sort ciliafa: a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3607980/
https://www.ncbi.nlm.nih.gov/pubmed/23351276
http://dx.doi.org/10.1186/2046-2530-1-14
work_keys_str_mv AT smithclairem ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT djakowjana ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT freerobertc ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT djakowpetr ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT lonnenrana ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT williamsgwyneth ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT pohunekpetr ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT hirstroberta ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT eastonandrewj ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT andrewpeterw ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware
AT ocallaghanchristopher ciliafaaresearchtoolforautomatedhighthroughputmeasurementofciliarybeatfrequencyusingfreelyavailablesoftware