Cargando…
Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma
BACKGROUND: Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharma...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3608328/ https://www.ncbi.nlm.nih.gov/pubmed/23316845 http://dx.doi.org/10.1186/1752-153X-7-7 |
_version_ | 1782264224552058880 |
---|---|
author | Iqbal, Muzaffar Wani, Tanveer A Khalil, Nasr Y Darwish, Ibrahim A |
author_facet | Iqbal, Muzaffar Wani, Tanveer A Khalil, Nasr Y Darwish, Ibrahim A |
author_sort | Iqbal, Muzaffar |
collection | PubMed |
description | BACKGROUND: Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. RESULTS: A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS) were separated on Acquity UPLC BEH™ C(18) column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v) pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 260.1 > 149.0 and m/z 237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation. CONCLUSION: The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans. |
format | Online Article Text |
id | pubmed-3608328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36083282013-03-27 Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma Iqbal, Muzaffar Wani, Tanveer A Khalil, Nasr Y Darwish, Ibrahim A Chem Cent J Research Article BACKGROUND: Lenalidomide (LND) is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. RESULTS: A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS) were separated on Acquity UPLC BEH™ C(18) column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v) pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM) mode. The precursor to product ion transitions of m/z 260.1 > 149.0 and m/z 237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation. CONCLUSION: The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans. BioMed Central 2013-01-14 /pmc/articles/PMC3608328/ /pubmed/23316845 http://dx.doi.org/10.1186/1752-153X-7-7 Text en Copyright ©2013 Iqbal et al; licensee Chemistry Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Iqbal, Muzaffar Wani, Tanveer A Khalil, Nasr Y Darwish, Ibrahim A Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title | Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title_full | Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title_fullStr | Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title_full_unstemmed | Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title_short | Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
title_sort | development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3608328/ https://www.ncbi.nlm.nih.gov/pubmed/23316845 http://dx.doi.org/10.1186/1752-153X-7-7 |
work_keys_str_mv | AT iqbalmuzaffar developmentandvalidationofultraperformanceliquidchromatographicmethodwithtandemmassspectrometryfordeterminationoflenalidomideinrabbitandhumanplasma AT wanitanveera developmentandvalidationofultraperformanceliquidchromatographicmethodwithtandemmassspectrometryfordeterminationoflenalidomideinrabbitandhumanplasma AT khalilnasry developmentandvalidationofultraperformanceliquidchromatographicmethodwithtandemmassspectrometryfordeterminationoflenalidomideinrabbitandhumanplasma AT darwishibrahima developmentandvalidationofultraperformanceliquidchromatographicmethodwithtandemmassspectrometryfordeterminationoflenalidomideinrabbitandhumanplasma |