Cargando…
Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill
BACKGROUND: Handrim wheelchair propulsion is a complex bimanual motor task. The bimanually applied forces on the rims determine the speed and direction of locomotion. Measurements of forces and torques on the handrim are important to study status and change of propulsion technique (and consequently...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614450/ https://www.ncbi.nlm.nih.gov/pubmed/23360756 http://dx.doi.org/10.1186/1743-0003-10-9 |
_version_ | 1782264842145497088 |
---|---|
author | Vegter, Riemer JK Lamoth, Claudine J de Groot, Sonja Veeger, Dirkjan HEJ van der Woude, Lucas HV |
author_facet | Vegter, Riemer JK Lamoth, Claudine J de Groot, Sonja Veeger, Dirkjan HEJ van der Woude, Lucas HV |
author_sort | Vegter, Riemer JK |
collection | PubMed |
description | BACKGROUND: Handrim wheelchair propulsion is a complex bimanual motor task. The bimanually applied forces on the rims determine the speed and direction of locomotion. Measurements of forces and torques on the handrim are important to study status and change of propulsion technique (and consequently mechanical strain) due to processes of learning, training or the wheelchair configuration. The purpose of this study was to compare the simultaneous outcomes of two different measurement-wheels attached to the different sides of the wheelchair, to determine measurement consistency within and between these wheels given the expected inter- and intra-limb variability as a consequence of motor control. METHODS: Nine able-bodied subjects received a three-week low-intensity handrim wheelchair practice intervention. They then performed three four-minute trials of wheelchair propulsion in an instrumented hand rim wheelchair on a motor-driven treadmill at a fixed belt speed. The two measurement-wheels on each side of the wheelchair measured forces and torques of one of the two upper limbs, which simultaneously perform the push action over time. The resulting data were compared as direct output using cross-correlation on the torque around the wheel-axle. Calculated push characteristics such as power production and speed were compared using an intra-class correlation. RESULTS: Measured torque around the wheel axle of the two measurement-wheels had a high average cross-correlation of 0.98 (std=0.01). Unilateral mean power output over a minute was found to have an intra-class correlation of 0.89 between the wheels. Although the difference over the pushes between left and right power output had a high variability, the mean difference between the measurement-wheels was low at 0.03 W (std=1.60). Other push characteristics showed even higher ICC’s (>0.9). CONCLUSIONS: A good agreement between both measurement-wheels was found at the level of the power output. This indicates a high comparability of the measurement-wheels for the different propulsion parameters. Data from both wheels seem suitable to be used together or interchangeably in experiments on motor control and wheelchair propulsion performance. A high variability in forces and timing between the left and right side were found during the execution of this bimanual task, reflecting the human motor control process. |
format | Online Article Text |
id | pubmed-3614450 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36144502013-04-03 Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill Vegter, Riemer JK Lamoth, Claudine J de Groot, Sonja Veeger, Dirkjan HEJ van der Woude, Lucas HV J Neuroeng Rehabil Research BACKGROUND: Handrim wheelchair propulsion is a complex bimanual motor task. The bimanually applied forces on the rims determine the speed and direction of locomotion. Measurements of forces and torques on the handrim are important to study status and change of propulsion technique (and consequently mechanical strain) due to processes of learning, training or the wheelchair configuration. The purpose of this study was to compare the simultaneous outcomes of two different measurement-wheels attached to the different sides of the wheelchair, to determine measurement consistency within and between these wheels given the expected inter- and intra-limb variability as a consequence of motor control. METHODS: Nine able-bodied subjects received a three-week low-intensity handrim wheelchair practice intervention. They then performed three four-minute trials of wheelchair propulsion in an instrumented hand rim wheelchair on a motor-driven treadmill at a fixed belt speed. The two measurement-wheels on each side of the wheelchair measured forces and torques of one of the two upper limbs, which simultaneously perform the push action over time. The resulting data were compared as direct output using cross-correlation on the torque around the wheel-axle. Calculated push characteristics such as power production and speed were compared using an intra-class correlation. RESULTS: Measured torque around the wheel axle of the two measurement-wheels had a high average cross-correlation of 0.98 (std=0.01). Unilateral mean power output over a minute was found to have an intra-class correlation of 0.89 between the wheels. Although the difference over the pushes between left and right power output had a high variability, the mean difference between the measurement-wheels was low at 0.03 W (std=1.60). Other push characteristics showed even higher ICC’s (>0.9). CONCLUSIONS: A good agreement between both measurement-wheels was found at the level of the power output. This indicates a high comparability of the measurement-wheels for the different propulsion parameters. Data from both wheels seem suitable to be used together or interchangeably in experiments on motor control and wheelchair propulsion performance. A high variability in forces and timing between the left and right side were found during the execution of this bimanual task, reflecting the human motor control process. BioMed Central 2013-01-29 /pmc/articles/PMC3614450/ /pubmed/23360756 http://dx.doi.org/10.1186/1743-0003-10-9 Text en Copyright © 2013 Vegter et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Vegter, Riemer JK Lamoth, Claudine J de Groot, Sonja Veeger, Dirkjan HEJ van der Woude, Lucas HV Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title | Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title_full | Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title_fullStr | Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title_full_unstemmed | Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title_short | Variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
title_sort | variability in bimanual wheelchair propulsion: consistency of two instrumented wheels during handrim wheelchair propulsion on a motor driven treadmill |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614450/ https://www.ncbi.nlm.nih.gov/pubmed/23360756 http://dx.doi.org/10.1186/1743-0003-10-9 |
work_keys_str_mv | AT vegterriemerjk variabilityinbimanualwheelchairpropulsionconsistencyoftwoinstrumentedwheelsduringhandrimwheelchairpropulsiononamotordriventreadmill AT lamothclaudinej variabilityinbimanualwheelchairpropulsionconsistencyoftwoinstrumentedwheelsduringhandrimwheelchairpropulsiononamotordriventreadmill AT degrootsonja variabilityinbimanualwheelchairpropulsionconsistencyoftwoinstrumentedwheelsduringhandrimwheelchairpropulsiononamotordriventreadmill AT veegerdirkjanhej variabilityinbimanualwheelchairpropulsionconsistencyoftwoinstrumentedwheelsduringhandrimwheelchairpropulsiononamotordriventreadmill AT vanderwoudelucashv variabilityinbimanualwheelchairpropulsionconsistencyoftwoinstrumentedwheelsduringhandrimwheelchairpropulsiononamotordriventreadmill |