A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Master Publishing Group
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614714/ https://www.ncbi.nlm.nih.gov/pubmed/23675103 |
_version_ | 1782264899298131968 |
---|---|
author | Al-Arfaj, Nawal Ahmad Al-Abdulkareem, Eman Abdullah Aly, Fatma Ahmad |
author_facet | Al-Arfaj, Nawal Ahmad Al-Abdulkareem, Eman Abdullah Aly, Fatma Ahmad |
author_sort | Al-Arfaj, Nawal Ahmad |
collection | PubMed |
description | Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10(-8) and 10(-4) M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10(-9) M (3.17 ng ml(-1)) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10(-8) M (9.63 ng ml(-1)). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: C(max)=785.8 ng ml(-1), t(max)=1.5 h, K(e)=0.125 h(-1) and t(1/2)=8 h which are favorably compared with those reported in literature. |
format | Online Article Text |
id | pubmed-3614714 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Master Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-36147142013-05-01 A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids Al-Arfaj, Nawal Ahmad Al-Abdulkareem, Eman Abdullah Aly, Fatma Ahmad Int J Biomed Sci Article Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10(-8) and 10(-4) M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10(-9) M (3.17 ng ml(-1)) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10(-8) M (9.63 ng ml(-1)). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: C(max)=785.8 ng ml(-1), t(max)=1.5 h, K(e)=0.125 h(-1) and t(1/2)=8 h which are favorably compared with those reported in literature. Master Publishing Group 2008-12 /pmc/articles/PMC3614714/ /pubmed/23675103 Text en © Nawal Ahmad Al-Arfaj et al. Licensee Master Publishing Group http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Article Al-Arfaj, Nawal Ahmad Al-Abdulkareem, Eman Abdullah Aly, Fatma Ahmad A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title | A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title_full | A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title_fullStr | A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title_full_unstemmed | A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title_short | A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids |
title_sort | validated adsorptive stripping voltammetric determination of antidiabetic agent pioglitazone hcl in tablets and biological fluids |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614714/ https://www.ncbi.nlm.nih.gov/pubmed/23675103 |
work_keys_str_mv | AT alarfajnawalahmad avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids AT alabdulkareememanabdullah avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids AT alyfatmaahmad avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids AT alarfajnawalahmad validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids AT alabdulkareememanabdullah validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids AT alyfatmaahmad validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids |