Cargando…

A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids

Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment,...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Arfaj, Nawal Ahmad, Al-Abdulkareem, Eman Abdullah, Aly, Fatma Ahmad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Master Publishing Group 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614714/
https://www.ncbi.nlm.nih.gov/pubmed/23675103
_version_ 1782264899298131968
author Al-Arfaj, Nawal Ahmad
Al-Abdulkareem, Eman Abdullah
Aly, Fatma Ahmad
author_facet Al-Arfaj, Nawal Ahmad
Al-Abdulkareem, Eman Abdullah
Aly, Fatma Ahmad
author_sort Al-Arfaj, Nawal Ahmad
collection PubMed
description Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10(-8) and 10(-4) M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10(-9) M (3.17 ng ml(-1)) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10(-8) M (9.63 ng ml(-1)). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: C(max)=785.8 ng ml(-1), t(max)=1.5 h, K(e)=0.125 h(-1) and t(1/2)=8 h which are favorably compared with those reported in literature.
format Online
Article
Text
id pubmed-3614714
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Master Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-36147142013-05-01 A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids Al-Arfaj, Nawal Ahmad Al-Abdulkareem, Eman Abdullah Aly, Fatma Ahmad Int J Biomed Sci Article Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the peak current is proportional to the concentration of pioglitazone HCl, and a linear calibration graphs were obtained within the concentration levels of 10(-8) and 10(-4) M following different accumulation time periods (0-300 s). The obtained results were analyzed and the statistical parameters were calculated. The detection limit is 8.08 × 10(-9) M (3.17 ng ml(-1)) using 300 s pre-concentration time, whereas the quantitative limit is 2.45 × 10(-8) M (9.63 ng ml(-1)). The proposed method was applied to assay the drug in pharmaceutical formulations and biological fluids. The pharmacokinetic parameters of drug in human plasma were estimated as: C(max)=785.8 ng ml(-1), t(max)=1.5 h, K(e)=0.125 h(-1) and t(1/2)=8 h which are favorably compared with those reported in literature. Master Publishing Group 2008-12 /pmc/articles/PMC3614714/ /pubmed/23675103 Text en © Nawal Ahmad Al-Arfaj et al. Licensee Master Publishing Group http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Al-Arfaj, Nawal Ahmad
Al-Abdulkareem, Eman Abdullah
Aly, Fatma Ahmad
A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title_full A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title_fullStr A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title_full_unstemmed A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title_short A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids
title_sort validated adsorptive stripping voltammetric determination of antidiabetic agent pioglitazone hcl in tablets and biological fluids
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614714/
https://www.ncbi.nlm.nih.gov/pubmed/23675103
work_keys_str_mv AT alarfajnawalahmad avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids
AT alabdulkareememanabdullah avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids
AT alyfatmaahmad avalidatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids
AT alarfajnawalahmad validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids
AT alabdulkareememanabdullah validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids
AT alyfatmaahmad validatedadsorptivestrippingvoltammetricdeterminationofantidiabeticagentpioglitazonehclintabletsandbiologicalfluids