Cargando…

A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples

A rapid, sensitive and accurate high performance liquid chromatography with UV detection method was developed and validated for the quantification of gabapentin in bulk, pharmaceutical formulation and human urine samples. Most of the published methods for analysis of gabapentin used derivatization w...

Descripción completa

Detalles Bibliográficos
Autores principales: Gujral, Rajinder Singh, Haque, Sk Manirul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Master Publishing Group 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614774/
https://www.ncbi.nlm.nih.gov/pubmed/23675131
_version_ 1782264912593027072
author Gujral, Rajinder Singh
Haque, Sk Manirul
author_facet Gujral, Rajinder Singh
Haque, Sk Manirul
author_sort Gujral, Rajinder Singh
collection PubMed
description A rapid, sensitive and accurate high performance liquid chromatography with UV detection method was developed and validated for the quantification of gabapentin in bulk, pharmaceutical formulation and human urine samples. Most of the published methods for analysis of gabapentin used derivatization with reagent. The present paper however describes the analysis of gabapentin without any derivatization. The chromatographic separation was carried out on a Waters C(18) 5 μm column (150 mm × 4.6 mm) using a mixture of methanol – acetonitrile - potassium dihydrogen orthophosphate (pH5.2; 0.028 M) (25:10:65) as a mobile phase with UV detection at 210 nm. The method was linear over the range of 0.1–3.8 mg/ml of gabapentin. The within day and between day precision values are very good.
format Online
Article
Text
id pubmed-3614774
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Master Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-36147742013-05-01 A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples Gujral, Rajinder Singh Haque, Sk Manirul Int J Biomed Sci Article A rapid, sensitive and accurate high performance liquid chromatography with UV detection method was developed and validated for the quantification of gabapentin in bulk, pharmaceutical formulation and human urine samples. Most of the published methods for analysis of gabapentin used derivatization with reagent. The present paper however describes the analysis of gabapentin without any derivatization. The chromatographic separation was carried out on a Waters C(18) 5 μm column (150 mm × 4.6 mm) using a mixture of methanol – acetonitrile - potassium dihydrogen orthophosphate (pH5.2; 0.028 M) (25:10:65) as a mobile phase with UV detection at 210 nm. The method was linear over the range of 0.1–3.8 mg/ml of gabapentin. The within day and between day precision values are very good. Master Publishing Group 2009-06 /pmc/articles/PMC3614774/ /pubmed/23675131 Text en © Rajinder Singh Gujral et al. Licensee Master Publishing Group http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Gujral, Rajinder Singh
Haque, Sk Manirul
A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title_full A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title_fullStr A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title_full_unstemmed A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title_short A Validated Method without Derivatization for the Determination of Gabapentin in Bulk, Pharmaceutical Formulation and Human Urine Samples
title_sort validated method without derivatization for the determination of gabapentin in bulk, pharmaceutical formulation and human urine samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614774/
https://www.ncbi.nlm.nih.gov/pubmed/23675131
work_keys_str_mv AT gujralrajindersingh avalidatedmethodwithoutderivatizationforthedeterminationofgabapentininbulkpharmaceuticalformulationandhumanurinesamples
AT haqueskmanirul avalidatedmethodwithoutderivatizationforthedeterminationofgabapentininbulkpharmaceuticalformulationandhumanurinesamples
AT gujralrajindersingh validatedmethodwithoutderivatizationforthedeterminationofgabapentininbulkpharmaceuticalformulationandhumanurinesamples
AT haqueskmanirul validatedmethodwithoutderivatizationforthedeterminationofgabapentininbulkpharmaceuticalformulationandhumanurinesamples