Cargando…
Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Master Publishing Group
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614844/ https://www.ncbi.nlm.nih.gov/pubmed/23675248 |
_version_ | 1782264928731660288 |
---|---|
author | Ashour, Safwan Omar, Soulafa |
author_facet | Ashour, Safwan Omar, Soulafa |
author_sort | Ashour, Safwan |
collection | PubMed |
description | A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of a mixture of 0.1M formic acid and methanol (25:75, v/v), pumped at a flow rate 1.0 mL min(-1). The photodiode array detector was operated at 280 nm. The retention times for rosuvastatin and fluvastatin, which was used as internal standard, were 3.98 and 7.78 min, respectively. Linearity range (r(2) better than 0.999, n=6) was 3.0-1602.0 μg mL(-1) with limit of detection value of 0.12 μg mL(-1). The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.40%, while the recovery was 99.86-102.86%. The method was applied in the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control. |
format | Online Article Text |
id | pubmed-3614844 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Master Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-36148442013-05-01 Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations Ashour, Safwan Omar, Soulafa Int J Biomed Sci Article A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of a mixture of 0.1M formic acid and methanol (25:75, v/v), pumped at a flow rate 1.0 mL min(-1). The photodiode array detector was operated at 280 nm. The retention times for rosuvastatin and fluvastatin, which was used as internal standard, were 3.98 and 7.78 min, respectively. Linearity range (r(2) better than 0.999, n=6) was 3.0-1602.0 μg mL(-1) with limit of detection value of 0.12 μg mL(-1). The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.40%, while the recovery was 99.86-102.86%. The method was applied in the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control. Master Publishing Group 2011-12 /pmc/articles/PMC3614844/ /pubmed/23675248 Text en © Safwan Ashour et al. Licensee Master Publishing Group http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Article Ashour, Safwan Omar, Soulafa Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title | Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title_full | Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title_fullStr | Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title_full_unstemmed | Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title_short | Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations |
title_sort | validated high-performance liquid chromatographic method for the estimation of rosuvastatin calcium in bulk and pharmaceutical formulations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614844/ https://www.ncbi.nlm.nih.gov/pubmed/23675248 |
work_keys_str_mv | AT ashoursafwan validatedhighperformanceliquidchromatographicmethodfortheestimationofrosuvastatincalciuminbulkandpharmaceuticalformulations AT omarsoulafa validatedhighperformanceliquidchromatographicmethodfortheestimationofrosuvastatincalciuminbulkandpharmaceuticalformulations |