Cargando…

Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations

A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashour, Safwan, Omar, Soulafa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Master Publishing Group 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614844/
https://www.ncbi.nlm.nih.gov/pubmed/23675248
_version_ 1782264928731660288
author Ashour, Safwan
Omar, Soulafa
author_facet Ashour, Safwan
Omar, Soulafa
author_sort Ashour, Safwan
collection PubMed
description A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of a mixture of 0.1M formic acid and methanol (25:75, v/v), pumped at a flow rate 1.0 mL min(-1). The photodiode array detector was operated at 280 nm. The retention times for rosuvastatin and fluvastatin, which was used as internal standard, were 3.98 and 7.78 min, respectively. Linearity range (r(2) better than 0.999, n=6) was 3.0-1602.0 μg mL(-1) with limit of detection value of 0.12 μg mL(-1). The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.40%, while the recovery was 99.86-102.86%. The method was applied in the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control.
format Online
Article
Text
id pubmed-3614844
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Master Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-36148442013-05-01 Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations Ashour, Safwan Omar, Soulafa Int J Biomed Sci Article A reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of rosuvastatin calcium in pharmaceutical dosage forms. The determination was performed on a Nucleodur column C(8) (250 × 4.6 mm i.d., 5 μm particle size); the mobile phase consisted of a mixture of 0.1M formic acid and methanol (25:75, v/v), pumped at a flow rate 1.0 mL min(-1). The photodiode array detector was operated at 280 nm. The retention times for rosuvastatin and fluvastatin, which was used as internal standard, were 3.98 and 7.78 min, respectively. Linearity range (r(2) better than 0.999, n=6) was 3.0-1602.0 μg mL(-1) with limit of detection value of 0.12 μg mL(-1). The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 2.40%, while the recovery was 99.86-102.86%. The method was applied in the quality control of commercial tablets and content uniformity test and proved to be suitable for rapid and reliable quality control. Master Publishing Group 2011-12 /pmc/articles/PMC3614844/ /pubmed/23675248 Text en © Safwan Ashour et al. Licensee Master Publishing Group http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.5/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Ashour, Safwan
Omar, Soulafa
Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title_full Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title_fullStr Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title_full_unstemmed Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title_short Validated High-Performance Liquid Chromatographic Method for the Estimation of Rosuvastatin Calcium in Bulk and Pharmaceutical Formulations
title_sort validated high-performance liquid chromatographic method for the estimation of rosuvastatin calcium in bulk and pharmaceutical formulations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614844/
https://www.ncbi.nlm.nih.gov/pubmed/23675248
work_keys_str_mv AT ashoursafwan validatedhighperformanceliquidchromatographicmethodfortheestimationofrosuvastatincalciuminbulkandpharmaceuticalformulations
AT omarsoulafa validatedhighperformanceliquidchromatographicmethodfortheestimationofrosuvastatincalciuminbulkandpharmaceuticalformulations