Cargando…

Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms

PURPOSE: To evaluate longitudinal changes in corneal sensitivity, tear function, and corneal staining in patients who underwent laser in situ keratomileusis (LASIK) using two different femtosecond lasers. METHODS: In a prospective, randomized clinical trial, contralateral eyes of 45 patients underwe...

Descripción completa

Detalles Bibliográficos
Autores principales: Petznick, Andrea, Chew, Annabel, Hall, Reece C, Chan, Cordelia ML, Rosman, Mohamad, Tan, Donald, Tong, Louis, Mehta, Jodhbir S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3616690/
https://www.ncbi.nlm.nih.gov/pubmed/23576858
http://dx.doi.org/10.2147/OPTH.S42266
_version_ 1782265151794184192
author Petznick, Andrea
Chew, Annabel
Hall, Reece C
Chan, Cordelia ML
Rosman, Mohamad
Tan, Donald
Tong, Louis
Mehta, Jodhbir S
author_facet Petznick, Andrea
Chew, Annabel
Hall, Reece C
Chan, Cordelia ML
Rosman, Mohamad
Tan, Donald
Tong, Louis
Mehta, Jodhbir S
author_sort Petznick, Andrea
collection PubMed
description PURPOSE: To evaluate longitudinal changes in corneal sensitivity, tear function, and corneal staining in patients who underwent laser in situ keratomileusis (LASIK) using two different femtosecond lasers. METHODS: In a prospective, randomized clinical trial, contralateral eyes of 45 patients underwent flap creation by either VisuMax or IntraLase™ femtosecond laser. Corneal sensitivity, tear break up time (TBUT), Schirmer’s test, and corneal fluorescein staining were assessed preoperatively and at 1 week, 1 month, and 3 months postoperatively. RESULTS: There were no statistical differences in any clinical outcome measure between the two femtosecond lasers (P > 0.05), although there was a trend towards slightly lower reductions for corneal sensitivity and TBUT in VisuMax-operated eyes. Overall, corneal sensitivity was significantly reduced at 1 week (P < 0.05), 1 month (P < 0 .001), and 3 months (P < 0.001) postoperatively. A significantly greater reduction of corneal sensitivity was noted in eyes with a myopic spherical equivalent of −6.00 diopters (D) to −11.25 D as compared with eyes that had a relatively lower level of myopia of less than −6.00 D (P < 0.001). TBUT and Schirmer’s test values were significantly diminished at 1 week postoperatively (P < 0.04). Overall, corneal staining was significantly increased at 1 week postoperatively (P < 0.001). The level of myopia did not significantly affect postoperative changes in TBUT, Schirmer’s test values, or corneal staining (P > 0.05). CONCLUSION: This study showed that changes in corneal sensitivity, tear function, and corneal staining were statistically similar in LASIK using VisuMax and IntraLase femtosecond lasers for flap creation. However, the trend towards faster recovery of corneal sensitivity and TBUT observed in VisuMax-operated eyes may be attributable to improved technical specifications.
format Online
Article
Text
id pubmed-3616690
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-36166902013-04-10 Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms Petznick, Andrea Chew, Annabel Hall, Reece C Chan, Cordelia ML Rosman, Mohamad Tan, Donald Tong, Louis Mehta, Jodhbir S Clin Ophthalmol Original Research PURPOSE: To evaluate longitudinal changes in corneal sensitivity, tear function, and corneal staining in patients who underwent laser in situ keratomileusis (LASIK) using two different femtosecond lasers. METHODS: In a prospective, randomized clinical trial, contralateral eyes of 45 patients underwent flap creation by either VisuMax or IntraLase™ femtosecond laser. Corneal sensitivity, tear break up time (TBUT), Schirmer’s test, and corneal fluorescein staining were assessed preoperatively and at 1 week, 1 month, and 3 months postoperatively. RESULTS: There were no statistical differences in any clinical outcome measure between the two femtosecond lasers (P > 0.05), although there was a trend towards slightly lower reductions for corneal sensitivity and TBUT in VisuMax-operated eyes. Overall, corneal sensitivity was significantly reduced at 1 week (P < 0.05), 1 month (P < 0 .001), and 3 months (P < 0.001) postoperatively. A significantly greater reduction of corneal sensitivity was noted in eyes with a myopic spherical equivalent of −6.00 diopters (D) to −11.25 D as compared with eyes that had a relatively lower level of myopia of less than −6.00 D (P < 0.001). TBUT and Schirmer’s test values were significantly diminished at 1 week postoperatively (P < 0.04). Overall, corneal staining was significantly increased at 1 week postoperatively (P < 0.001). The level of myopia did not significantly affect postoperative changes in TBUT, Schirmer’s test values, or corneal staining (P > 0.05). CONCLUSION: This study showed that changes in corneal sensitivity, tear function, and corneal staining were statistically similar in LASIK using VisuMax and IntraLase femtosecond lasers for flap creation. However, the trend towards faster recovery of corneal sensitivity and TBUT observed in VisuMax-operated eyes may be attributable to improved technical specifications. Dove Medical Press 2013 2013-03-24 /pmc/articles/PMC3616690/ /pubmed/23576858 http://dx.doi.org/10.2147/OPTH.S42266 Text en © 2013 Petznick et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Petznick, Andrea
Chew, Annabel
Hall, Reece C
Chan, Cordelia ML
Rosman, Mohamad
Tan, Donald
Tong, Louis
Mehta, Jodhbir S
Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title_full Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title_fullStr Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title_full_unstemmed Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title_short Comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
title_sort comparison of corneal sensitivity, tear function and corneal staining following laser in situ keratomileusis with two femtosecond laser platforms
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3616690/
https://www.ncbi.nlm.nih.gov/pubmed/23576858
http://dx.doi.org/10.2147/OPTH.S42266
work_keys_str_mv AT petznickandrea comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT chewannabel comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT hallreecec comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT chancordeliaml comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT rosmanmohamad comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT tandonald comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT tonglouis comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms
AT mehtajodhbirs comparisonofcornealsensitivitytearfunctionandcornealstainingfollowinglaserinsitukeratomileusiswithtwofemtosecondlaserplatforms