Cargando…

A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care

BACKGROUND: The level of lactate in amniotic fluid may provide useful clinical information when assessing progress of a woman’s labour and if so, a rapid, reliable method to assess amniotic fluid lactate is required in order to be clinically relevant. However, measuring lactate levels in amniotic fl...

Descripción completa

Detalles Bibliográficos
Autores principales: Hall, Beverley, Iwasenko, Jenna, Moriatis, Mary, Rawlinson, William D, Tracy, Mark B, Tracy, Sally K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3618323/
https://www.ncbi.nlm.nih.gov/pubmed/23531401
http://dx.doi.org/10.1186/1756-0500-6-112
_version_ 1782265400717737984
author Hall, Beverley
Iwasenko, Jenna
Moriatis, Mary
Rawlinson, William D
Tracy, Mark B
Tracy, Sally K
author_facet Hall, Beverley
Iwasenko, Jenna
Moriatis, Mary
Rawlinson, William D
Tracy, Mark B
Tracy, Sally K
author_sort Hall, Beverley
collection PubMed
description BACKGROUND: The level of lactate in amniotic fluid may provide useful clinical information when assessing progress of a woman’s labour and if so, a rapid, reliable method to assess amniotic fluid lactate is required in order to be clinically relevant. However, measuring lactate levels in amniotic fluid, using portable, handheld lactate meters may be less accurate than reference laboratory instruments designed to measure lactate levels in aqueous solutions. Prior to conducting a large study, we assessed recruitment, consent and sampling procedures, and the accuracy of a handheld lactate meter to measure lactate in amniotic fluid. We compared amniotic fluid lactate results obtained using the hand held Lactate Pro (Arkray) to results obtained using reference laboratory methods ABX Pentra 400 (Horiba). RESULTS: We recruited 35 nulliparous women during their antenatal hospital visits and tested amniotic fluid samples collected from 20 labouring women. The handheld Lactate Pro meter was found accurate from 9–20 mmol/L with a Passing & Bablok regression of y = 0.18 + 0.97x (95% CI 0.76–1.45). Amniotic fluid lactate results remained reliable in the presence of potential contaminants commonly encountered during labour; obstetric lubricant, blood and meconium. CONCLUSION: The measurement of amniotic fluid lactate using the Lactate Pro meter was reliable compared to reference laboratory methods for measuring lactate levels in amniotic fluid. The pilot study enabled the refinement of information, recruitment, consenting and sampling procedures prior to commencing a large cohort study.
format Online
Article
Text
id pubmed-3618323
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36183232013-04-07 A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care Hall, Beverley Iwasenko, Jenna Moriatis, Mary Rawlinson, William D Tracy, Mark B Tracy, Sally K BMC Res Notes Research Article BACKGROUND: The level of lactate in amniotic fluid may provide useful clinical information when assessing progress of a woman’s labour and if so, a rapid, reliable method to assess amniotic fluid lactate is required in order to be clinically relevant. However, measuring lactate levels in amniotic fluid, using portable, handheld lactate meters may be less accurate than reference laboratory instruments designed to measure lactate levels in aqueous solutions. Prior to conducting a large study, we assessed recruitment, consent and sampling procedures, and the accuracy of a handheld lactate meter to measure lactate in amniotic fluid. We compared amniotic fluid lactate results obtained using the hand held Lactate Pro (Arkray) to results obtained using reference laboratory methods ABX Pentra 400 (Horiba). RESULTS: We recruited 35 nulliparous women during their antenatal hospital visits and tested amniotic fluid samples collected from 20 labouring women. The handheld Lactate Pro meter was found accurate from 9–20 mmol/L with a Passing & Bablok regression of y = 0.18 + 0.97x (95% CI 0.76–1.45). Amniotic fluid lactate results remained reliable in the presence of potential contaminants commonly encountered during labour; obstetric lubricant, blood and meconium. CONCLUSION: The measurement of amniotic fluid lactate using the Lactate Pro meter was reliable compared to reference laboratory methods for measuring lactate levels in amniotic fluid. The pilot study enabled the refinement of information, recruitment, consenting and sampling procedures prior to commencing a large cohort study. BioMed Central 2013-03-26 /pmc/articles/PMC3618323/ /pubmed/23531401 http://dx.doi.org/10.1186/1756-0500-6-112 Text en Copyright © 2013 Hall et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hall, Beverley
Iwasenko, Jenna
Moriatis, Mary
Rawlinson, William D
Tracy, Mark B
Tracy, Sally K
A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title_full A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title_fullStr A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title_full_unstemmed A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title_short A pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
title_sort pilot study to determine the feasibility of collecting amniotic fluid samples from women during labour and measuring amniotic fluid lactate at point of care
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3618323/
https://www.ncbi.nlm.nih.gov/pubmed/23531401
http://dx.doi.org/10.1186/1756-0500-6-112
work_keys_str_mv AT hallbeverley apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT iwasenkojenna apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT moriatismary apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT rawlinsonwilliamd apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT tracymarkb apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT tracysallyk apilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT hallbeverley pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT iwasenkojenna pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT moriatismary pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT rawlinsonwilliamd pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT tracymarkb pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare
AT tracysallyk pilotstudytodeterminethefeasibilityofcollectingamnioticfluidsamplesfromwomenduringlabourandmeasuringamnioticfluidlactateatpointofcare