Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy

BACKGROUND: Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT). Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs) when stereotactic ablative...

Descripción completa

Detalles Bibliográficos
Autores principales: Chi, Alexander, Ma, Pan, Fu, Guishan, Hobbs, Gerry, Welsh, James S., Nguyen, Nam P., Jang, Si Young, Dai, Jinrong, Jin, Jing, Komaki, Ritsuko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3618449/
https://www.ncbi.nlm.nih.gov/pubmed/23577071
http://dx.doi.org/10.1371/journal.pone.0059729
_version_ 1782265422612004864
author Chi, Alexander
Ma, Pan
Fu, Guishan
Hobbs, Gerry
Welsh, James S.
Nguyen, Nam P.
Jang, Si Young
Dai, Jinrong
Jin, Jing
Komaki, Ritsuko
author_facet Chi, Alexander
Ma, Pan
Fu, Guishan
Hobbs, Gerry
Welsh, James S.
Nguyen, Nam P.
Jang, Si Young
Dai, Jinrong
Jin, Jing
Komaki, Ritsuko
author_sort Chi, Alexander
collection PubMed
description BACKGROUND: Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT). Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs) when stereotactic ablative radiotherapy (SABR) is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. METHODS: 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0) plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV). Target and OAR dose parameters were compared. Each technique’s ability to meet dose constraints was further investigated. RESULTS: HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints) (p = 0.0004). All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. CONCLUSION: HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing.
format Online
Article
Text
id pubmed-3618449
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36184492013-04-10 Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy Chi, Alexander Ma, Pan Fu, Guishan Hobbs, Gerry Welsh, James S. Nguyen, Nam P. Jang, Si Young Dai, Jinrong Jin, Jing Komaki, Ritsuko PLoS One Research Article BACKGROUND: Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT). Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs) when stereotactic ablative radiotherapy (SABR) is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. METHODS: 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0) plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV). Target and OAR dose parameters were compared. Each technique’s ability to meet dose constraints was further investigated. RESULTS: HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints) (p = 0.0004). All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. CONCLUSION: HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing. Public Library of Science 2013-04-05 /pmc/articles/PMC3618449/ /pubmed/23577071 http://dx.doi.org/10.1371/journal.pone.0059729 Text en © 2013 Chi et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Chi, Alexander
Ma, Pan
Fu, Guishan
Hobbs, Gerry
Welsh, James S.
Nguyen, Nam P.
Jang, Si Young
Dai, Jinrong
Jin, Jing
Komaki, Ritsuko
Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title_full Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title_fullStr Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title_full_unstemmed Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title_short Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
title_sort critical structure sparing in stereotactic ablative radiotherapy for central lung lesions: helical tomotherapy vs. volumetric modulated arc therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3618449/
https://www.ncbi.nlm.nih.gov/pubmed/23577071
http://dx.doi.org/10.1371/journal.pone.0059729
work_keys_str_mv AT chialexander criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT mapan criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT fuguishan criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT hobbsgerry criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT welshjamess criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT nguyennamp criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT jangsiyoung criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT daijinrong criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT jinjing criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy
AT komakiritsuko criticalstructuresparinginstereotacticablativeradiotherapyforcentrallunglesionshelicaltomotherapyvsvolumetricmodulatedarctherapy