Cargando…
Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography
Purpose. To analyse the diurnal variation of central choroidal thickness (CCT) in healthy emetropic patients during working hours. Methods. Fifty healthy young emmetrpic volunteers were included in this study. CCT was measured at 9 AM and 4 PM with spectral domain optical coherence tomography (Spect...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3622386/ https://www.ncbi.nlm.nih.gov/pubmed/23589769 http://dx.doi.org/10.1155/2013/687165 |
_version_ | 1782265827530113024 |
---|---|
author | Osmanbasoglu, Ozen Ayrancı Alkin, Zeynep Ozkaya, Abdullah Ozpınar, Yavuz Yazici, Ahmet Taylan Demirok, Ahmet |
author_facet | Osmanbasoglu, Ozen Ayrancı Alkin, Zeynep Ozkaya, Abdullah Ozpınar, Yavuz Yazici, Ahmet Taylan Demirok, Ahmet |
author_sort | Osmanbasoglu, Ozen Ayrancı |
collection | PubMed |
description | Purpose. To analyse the diurnal variation of central choroidal thickness (CCT) in healthy emetropic patients during working hours. Methods. Fifty healthy young emmetrpic volunteers were included in this study. CCT was measured at 9 AM and 4 PM with spectral domain optical coherence tomography (Spectralis, Heidelberg Engineering) with enhanced depth imaging. Diurnal variation of CCT, the correlation between rigth and left eyes and the demographic factors affecting this variation were assessed. Findings. The mean CCT at 9 AM and 4 PM was 308.7 ± 64.5 μm and 308.7 ± 62 μm, respectively, with a mean diurnal amplitude of −0.03 ± 14.7 μm, ranging between −55 μm and 47 μm, the difference was statistically insignificant (P: 0.9). There were positive correlations between right and left eyes among CCT measurements at 9 AM, 4 PM and the mean amplitude of diurnal change (r: 0.65, P < 0.01; r: 0.60, P < 0.01; r: 0.45, P: 0.00, resp.). There was a statistically significant negative correlation between the magnitude of diurnal change and age (r: −0.27, P: 0.01). Conclusion. Although the mean CCT in the all group does not show significant variation during working hours, the pattern of diurnal variation may vary from person to person according to age, and there is a great harmony between the two eyes. |
format | Online Article Text |
id | pubmed-3622386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36223862013-04-15 Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography Osmanbasoglu, Ozen Ayrancı Alkin, Zeynep Ozkaya, Abdullah Ozpınar, Yavuz Yazici, Ahmet Taylan Demirok, Ahmet J Ophthalmol Clinical Study Purpose. To analyse the diurnal variation of central choroidal thickness (CCT) in healthy emetropic patients during working hours. Methods. Fifty healthy young emmetrpic volunteers were included in this study. CCT was measured at 9 AM and 4 PM with spectral domain optical coherence tomography (Spectralis, Heidelberg Engineering) with enhanced depth imaging. Diurnal variation of CCT, the correlation between rigth and left eyes and the demographic factors affecting this variation were assessed. Findings. The mean CCT at 9 AM and 4 PM was 308.7 ± 64.5 μm and 308.7 ± 62 μm, respectively, with a mean diurnal amplitude of −0.03 ± 14.7 μm, ranging between −55 μm and 47 μm, the difference was statistically insignificant (P: 0.9). There were positive correlations between right and left eyes among CCT measurements at 9 AM, 4 PM and the mean amplitude of diurnal change (r: 0.65, P < 0.01; r: 0.60, P < 0.01; r: 0.45, P: 0.00, resp.). There was a statistically significant negative correlation between the magnitude of diurnal change and age (r: −0.27, P: 0.01). Conclusion. Although the mean CCT in the all group does not show significant variation during working hours, the pattern of diurnal variation may vary from person to person according to age, and there is a great harmony between the two eyes. Hindawi Publishing Corporation 2013 2013-03-27 /pmc/articles/PMC3622386/ /pubmed/23589769 http://dx.doi.org/10.1155/2013/687165 Text en Copyright © 2013 Ozen Ayrancı Osmanbasoglu et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Study Osmanbasoglu, Ozen Ayrancı Alkin, Zeynep Ozkaya, Abdullah Ozpınar, Yavuz Yazici, Ahmet Taylan Demirok, Ahmet Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title | Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title_full | Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title_fullStr | Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title_full_unstemmed | Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title_short | Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography |
title_sort | diurnal choroidal thickness changes in normal eyes of turkish people measured by spectral domain optical coherence tomography |
topic | Clinical Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3622386/ https://www.ncbi.nlm.nih.gov/pubmed/23589769 http://dx.doi.org/10.1155/2013/687165 |
work_keys_str_mv | AT osmanbasogluozenayrancı diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography AT alkinzeynep diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography AT ozkayaabdullah diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography AT ozpınaryavuz diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography AT yaziciahmettaylan diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography AT demirokahmet diurnalchoroidalthicknesschangesinnormaleyesofturkishpeoplemeasuredbyspectraldomainopticalcoherencetomography |