Cargando…

Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review

Purpose. Interventional treatment strategies for patients with encephalopathy due to splenorenal shunt remain controversial. Portosplenic blood flow separation by occluding the splenic vein could avoid the complication of severe portal hypertension, but it would require repeated reintervention due t...

Descripción completa

Detalles Bibliográficos
Autores principales: Inoue, Masayoshi, Tanaka, Toshihiro, Nakagawa, Hiroyuki, Yoshioka, Tetsuya, Kichikawa, Kimihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3623118/
https://www.ncbi.nlm.nih.gov/pubmed/23607030
http://dx.doi.org/10.1155/2013/160653
_version_ 1782265911446601728
author Inoue, Masayoshi
Tanaka, Toshihiro
Nakagawa, Hiroyuki
Yoshioka, Tetsuya
Kichikawa, Kimihiko
author_facet Inoue, Masayoshi
Tanaka, Toshihiro
Nakagawa, Hiroyuki
Yoshioka, Tetsuya
Kichikawa, Kimihiko
author_sort Inoue, Masayoshi
collection PubMed
description Purpose. Interventional treatment strategies for patients with encephalopathy due to splenorenal shunt remain controversial. Portosplenic blood flow separation by occluding the splenic vein could avoid the complication of severe portal hypertension, but it would require repeated reintervention due to recurrence of symptoms. This paper describes occlusion of the splenic vein using coil anchors and prophylactic embolization of a collateral hepatofugal vessel with no recurrence of hyperammonemia. Materials and Methods. A 51-year-old woman with severe cirrhosis had hepatic encephalopathy due to a large splenorenal shunt. The serum ammonia level was 132 μg/dL. Via a transileocolic approach, the splenic vein was completely embolized with 0.035-inch metallic coils using coil anchors while preserving the splenorenal shunt. In addition, one of the collateral vessels of the portal vein, the retrogastric vein, was also embolized prophylactically. Results. After this procedure, the serum ammonia level decreased immediately to 24 μg/dL. The portal venous pressure increased by only 1.5 mmHg. Hepatic encephalopathy had not been observed for 25 months after the procedure, and neither retention of ascites nor worsening of esophageal varices and liver function was observed. Conclusion. This procedure appears to be safe and effective for hepatic encephalopathy caused by a splenorenal shunt.
format Online
Article
Text
id pubmed-3623118
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-36231182013-04-19 Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review Inoue, Masayoshi Tanaka, Toshihiro Nakagawa, Hiroyuki Yoshioka, Tetsuya Kichikawa, Kimihiko Case Rep Radiol Case Report Purpose. Interventional treatment strategies for patients with encephalopathy due to splenorenal shunt remain controversial. Portosplenic blood flow separation by occluding the splenic vein could avoid the complication of severe portal hypertension, but it would require repeated reintervention due to recurrence of symptoms. This paper describes occlusion of the splenic vein using coil anchors and prophylactic embolization of a collateral hepatofugal vessel with no recurrence of hyperammonemia. Materials and Methods. A 51-year-old woman with severe cirrhosis had hepatic encephalopathy due to a large splenorenal shunt. The serum ammonia level was 132 μg/dL. Via a transileocolic approach, the splenic vein was completely embolized with 0.035-inch metallic coils using coil anchors while preserving the splenorenal shunt. In addition, one of the collateral vessels of the portal vein, the retrogastric vein, was also embolized prophylactically. Results. After this procedure, the serum ammonia level decreased immediately to 24 μg/dL. The portal venous pressure increased by only 1.5 mmHg. Hepatic encephalopathy had not been observed for 25 months after the procedure, and neither retention of ascites nor worsening of esophageal varices and liver function was observed. Conclusion. This procedure appears to be safe and effective for hepatic encephalopathy caused by a splenorenal shunt. Hindawi Publishing Corporation 2013 2013-03-27 /pmc/articles/PMC3623118/ /pubmed/23607030 http://dx.doi.org/10.1155/2013/160653 Text en Copyright © 2013 Masayoshi Inoue et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Inoue, Masayoshi
Tanaka, Toshihiro
Nakagawa, Hiroyuki
Yoshioka, Tetsuya
Kichikawa, Kimihiko
Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title_full Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title_fullStr Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title_full_unstemmed Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title_short Splenic Vein Embolization Using Coil Anchors and Prophylactic Occlusion of a Hepatofugal Collateral for Hepatic Encephalopathy due to Splenorenal Shunt: Technical Note and Literature Review
title_sort splenic vein embolization using coil anchors and prophylactic occlusion of a hepatofugal collateral for hepatic encephalopathy due to splenorenal shunt: technical note and literature review
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3623118/
https://www.ncbi.nlm.nih.gov/pubmed/23607030
http://dx.doi.org/10.1155/2013/160653
work_keys_str_mv AT inouemasayoshi splenicveinembolizationusingcoilanchorsandprophylacticocclusionofahepatofugalcollateralforhepaticencephalopathyduetosplenorenalshunttechnicalnoteandliteraturereview
AT tanakatoshihiro splenicveinembolizationusingcoilanchorsandprophylacticocclusionofahepatofugalcollateralforhepaticencephalopathyduetosplenorenalshunttechnicalnoteandliteraturereview
AT nakagawahiroyuki splenicveinembolizationusingcoilanchorsandprophylacticocclusionofahepatofugalcollateralforhepaticencephalopathyduetosplenorenalshunttechnicalnoteandliteraturereview
AT yoshiokatetsuya splenicveinembolizationusingcoilanchorsandprophylacticocclusionofahepatofugalcollateralforhepaticencephalopathyduetosplenorenalshunttechnicalnoteandliteraturereview
AT kichikawakimihiko splenicveinembolizationusingcoilanchorsandprophylacticocclusionofahepatofugalcollateralforhepaticencephalopathyduetosplenorenalshunttechnicalnoteandliteraturereview