Cargando…
Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assa...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3625552/ https://www.ncbi.nlm.nih.gov/pubmed/23662241 http://dx.doi.org/10.1155/2013/746395 |
_version_ | 1782266101196914688 |
---|---|
author | Schlaf, G. Pollok-Kopp, B. Schabel, E. Altermann, W. |
author_facet | Schlaf, G. Pollok-Kopp, B. Schabel, E. Altermann, W. |
author_sort | Schlaf, G. |
collection | PubMed |
description | Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assay was developed as a standard procedure about forty years ago. The negative outcome of pretransplant crossmatching represents the most important requirement for a successful kidney graft survival. The artificially positive outcomes of CDC-based crossmatches due to the underlying disease Systemic Lupus Erythematosus (SLE), however, may lead to the unjustified refusal of adequate kidney grafts. Two prospective female recipients destined for a living as well as for a cadaver kidney donation, respectively, exhibited positive CDC-based crossmatch outcomes although for both patients no historical immunizing events were known. Furthermore, solid phase-based screening or antibody differentiation analyses never led to positive results. Immediate reruns of the CDC-based crossmatch assays using the alternative antibody monitoring system (AMS-)crossmatch ELISA resulted in unequivocally negative outcomes. Consequently both transplantations were performed without any immunological complications for the hitherto follow-up time of 25 and 28 months, respectively. We here show two case reports demonstrating an alternative methodical approach to circumvent CDC-based artefacts and point to the urgent need to substitute the CDC-based crossmatch procedure at least for special groups of patients. |
format | Online Article Text |
id | pubmed-3625552 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36255522013-05-09 Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools Schlaf, G. Pollok-Kopp, B. Schabel, E. Altermann, W. Case Rep Transplant Case Report Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assay was developed as a standard procedure about forty years ago. The negative outcome of pretransplant crossmatching represents the most important requirement for a successful kidney graft survival. The artificially positive outcomes of CDC-based crossmatches due to the underlying disease Systemic Lupus Erythematosus (SLE), however, may lead to the unjustified refusal of adequate kidney grafts. Two prospective female recipients destined for a living as well as for a cadaver kidney donation, respectively, exhibited positive CDC-based crossmatch outcomes although for both patients no historical immunizing events were known. Furthermore, solid phase-based screening or antibody differentiation analyses never led to positive results. Immediate reruns of the CDC-based crossmatch assays using the alternative antibody monitoring system (AMS-)crossmatch ELISA resulted in unequivocally negative outcomes. Consequently both transplantations were performed without any immunological complications for the hitherto follow-up time of 25 and 28 months, respectively. We here show two case reports demonstrating an alternative methodical approach to circumvent CDC-based artefacts and point to the urgent need to substitute the CDC-based crossmatch procedure at least for special groups of patients. Hindawi Publishing Corporation 2013 2013-03-28 /pmc/articles/PMC3625552/ /pubmed/23662241 http://dx.doi.org/10.1155/2013/746395 Text en Copyright © 2013 G. Schlaf et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Schlaf, G. Pollok-Kopp, B. Schabel, E. Altermann, W. Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title | Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title_full | Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title_fullStr | Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title_full_unstemmed | Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title_short | Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools |
title_sort | artificially positive crossmatches not leading to the refusal of kidney donations due to the usage of adequate diagnostic tools |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3625552/ https://www.ncbi.nlm.nih.gov/pubmed/23662241 http://dx.doi.org/10.1155/2013/746395 |
work_keys_str_mv | AT schlafg artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools AT pollokkoppb artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools AT schabele artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools AT altermannw artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools |