Cargando…

Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools

Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assa...

Descripción completa

Detalles Bibliográficos
Autores principales: Schlaf, G., Pollok-Kopp, B., Schabel, E., Altermann, W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3625552/
https://www.ncbi.nlm.nih.gov/pubmed/23662241
http://dx.doi.org/10.1155/2013/746395
_version_ 1782266101196914688
author Schlaf, G.
Pollok-Kopp, B.
Schabel, E.
Altermann, W.
author_facet Schlaf, G.
Pollok-Kopp, B.
Schabel, E.
Altermann, W.
author_sort Schlaf, G.
collection PubMed
description Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assay was developed as a standard procedure about forty years ago. The negative outcome of pretransplant crossmatching represents the most important requirement for a successful kidney graft survival. The artificially positive outcomes of CDC-based crossmatches due to the underlying disease Systemic Lupus Erythematosus (SLE), however, may lead to the unjustified refusal of adequate kidney grafts. Two prospective female recipients destined for a living as well as for a cadaver kidney donation, respectively, exhibited positive CDC-based crossmatch outcomes although for both patients no historical immunizing events were known. Furthermore, solid phase-based screening or antibody differentiation analyses never led to positive results. Immediate reruns of the CDC-based crossmatch assays using the alternative antibody monitoring system (AMS-)crossmatch ELISA resulted in unequivocally negative outcomes. Consequently both transplantations were performed without any immunological complications for the hitherto follow-up time of 25 and 28 months, respectively. We here show two case reports demonstrating an alternative methodical approach to circumvent CDC-based artefacts and point to the urgent need to substitute the CDC-based crossmatch procedure at least for special groups of patients.
format Online
Article
Text
id pubmed-3625552
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-36255522013-05-09 Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools Schlaf, G. Pollok-Kopp, B. Schabel, E. Altermann, W. Case Rep Transplant Case Report Allografting patients with human leukocyte antigens (HLA) which are recognized by preformed antibodies constitutes the main cause for hyper-acute or acute rejections. In order to select recipients without these donor-specific antibodies, the complement-dependent cytotoxicity crossmatch (CDC-CM) assay was developed as a standard procedure about forty years ago. The negative outcome of pretransplant crossmatching represents the most important requirement for a successful kidney graft survival. The artificially positive outcomes of CDC-based crossmatches due to the underlying disease Systemic Lupus Erythematosus (SLE), however, may lead to the unjustified refusal of adequate kidney grafts. Two prospective female recipients destined for a living as well as for a cadaver kidney donation, respectively, exhibited positive CDC-based crossmatch outcomes although for both patients no historical immunizing events were known. Furthermore, solid phase-based screening or antibody differentiation analyses never led to positive results. Immediate reruns of the CDC-based crossmatch assays using the alternative antibody monitoring system (AMS-)crossmatch ELISA resulted in unequivocally negative outcomes. Consequently both transplantations were performed without any immunological complications for the hitherto follow-up time of 25 and 28 months, respectively. We here show two case reports demonstrating an alternative methodical approach to circumvent CDC-based artefacts and point to the urgent need to substitute the CDC-based crossmatch procedure at least for special groups of patients. Hindawi Publishing Corporation 2013 2013-03-28 /pmc/articles/PMC3625552/ /pubmed/23662241 http://dx.doi.org/10.1155/2013/746395 Text en Copyright © 2013 G. Schlaf et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Schlaf, G.
Pollok-Kopp, B.
Schabel, E.
Altermann, W.
Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title_full Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title_fullStr Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title_full_unstemmed Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title_short Artificially Positive Crossmatches Not Leading to the Refusal of Kidney Donations due to the Usage of Adequate Diagnostic Tools
title_sort artificially positive crossmatches not leading to the refusal of kidney donations due to the usage of adequate diagnostic tools
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3625552/
https://www.ncbi.nlm.nih.gov/pubmed/23662241
http://dx.doi.org/10.1155/2013/746395
work_keys_str_mv AT schlafg artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools
AT pollokkoppb artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools
AT schabele artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools
AT altermannw artificiallypositivecrossmatchesnotleadingtotherefusalofkidneydonationsduetotheusageofadequatediagnostictools