Cargando…

Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?

OBJECTIVES: There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and...

Descripción completa

Detalles Bibliográficos
Autores principales: Costa, A. J., Lustig, S., Scholes, C. J., Balestro, J-C., Fatima, M., Parker, D. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Editorial Society of Bone and Joint Surgery 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626184/
https://www.ncbi.nlm.nih.gov/pubmed/23610696
http://dx.doi.org/10.1302/2046-3758.21.2000130
_version_ 1782266159670755328
author Costa, A. J.
Lustig, S.
Scholes, C. J.
Balestro, J-C.
Fatima, M.
Parker, D. A.
author_facet Costa, A. J.
Lustig, S.
Scholes, C. J.
Balestro, J-C.
Fatima, M.
Parker, D. A.
author_sort Costa, A. J.
collection PubMed
description OBJECTIVES: There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design. METHODS: A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated. RESULTS: Excellent intra- and interobserver reliability was observed for total coverage, when minimal component overhang (intraclass correlation coefficient (ICC) = 0.87) or no component overhang (ICC = 0.92) was permitted, regardless of rotational restrictions. CONCLUSIONS: Measurement of tibial coverage can be reliable using the templating method described even if the rotational axis selected still has a minor influence.
format Online
Article
Text
id pubmed-3626184
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher British Editorial Society of Bone and Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-36261842013-04-22 Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating? Costa, A. J. Lustig, S. Scholes, C. J. Balestro, J-C. Fatima, M. Parker, D. A. Bone Joint Res Knee OBJECTIVES: There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design. METHODS: A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated. RESULTS: Excellent intra- and interobserver reliability was observed for total coverage, when minimal component overhang (intraclass correlation coefficient (ICC) = 0.87) or no component overhang (ICC = 0.92) was permitted, regardless of rotational restrictions. CONCLUSIONS: Measurement of tibial coverage can be reliable using the templating method described even if the rotational axis selected still has a minor influence. British Editorial Society of Bone and Joint Surgery 2013-01-01 /pmc/articles/PMC3626184/ /pubmed/23610696 http://dx.doi.org/10.1302/2046-3758.21.2000130 Text en ©2013 British Editorial Society of Bone and Joint Surgery ©2013 British Editorial Society of Bone and Joint Surgery. This is an open-access article distributed under the terms of the Creative Commons Attributions licence, which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Knee
Costa, A. J.
Lustig, S.
Scholes, C. J.
Balestro, J-C.
Fatima, M.
Parker, D. A.
Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title_full Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title_fullStr Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title_full_unstemmed Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title_short Can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
title_sort can tibial coverage in total knee replacement be reliably evaluated with three-dimensional image-based digital templating?
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626184/
https://www.ncbi.nlm.nih.gov/pubmed/23610696
http://dx.doi.org/10.1302/2046-3758.21.2000130
work_keys_str_mv AT costaaj cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating
AT lustigs cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating
AT scholescj cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating
AT balestrojc cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating
AT fatimam cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating
AT parkerda cantibialcoverageintotalkneereplacementbereliablyevaluatedwiththreedimensionalimagebaseddigitaltemplating