Cargando…
Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody
We investigated the analytical interference of antithyroglobulin antibody (TgAb) to thyroglobulin (Tg) measurement and tried to convert measured Tg concentration to true Tg concentration using a mathematical equation which includes a concentration of TgAb. Methods. Tg was measured by immunoradiometr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626228/ https://www.ncbi.nlm.nih.gov/pubmed/23606837 http://dx.doi.org/10.1155/2013/210639 |
_version_ | 1782266169979305984 |
---|---|
author | Ahn, Byeong-Cheol Lee, Won Kee Jeong, Shin Young Lee, Sang-Woo Lee, Jaetae |
author_facet | Ahn, Byeong-Cheol Lee, Won Kee Jeong, Shin Young Lee, Sang-Woo Lee, Jaetae |
author_sort | Ahn, Byeong-Cheol |
collection | PubMed |
description | We investigated the analytical interference of antithyroglobulin antibody (TgAb) to thyroglobulin (Tg) measurement and tried to convert measured Tg concentration to true Tg concentration using a mathematical equation which includes a concentration of TgAb. Methods. Tg was measured by immunoradiometric assay and TgAb by radioimmunoassy. Experimental samples were produced by mixing Tg and TgAb standard solutions or mixing patients' serum with high Tg or high TgAb. Mathematical equations for prediction of expected Tg concentration with measured Tg and TgAb concentrations were deduced. The Tg concentration calculated using the equations was compared with the expected Tg concentration. Results. Measured Tg concentrations of samples having high TgAb were significantly lower than their expected Tg concentration. Magnitude of TgAb interference with the Tg assay showed a positive correlation with concentration of TgAb. Mathematical equations for estimation of expected Tg concentration using measured Tg and TgAb concentrations were successfully deduced and the calculated Tg concentration showed excellent correlation with expected Tg concentration. Conclusions. A mathematic equation for estimation of true Tg concentration using measured Tg and TgAb concentration was deduced. Tg concentration calculated by use of the equation might be more valuable than measured Tg concentration in patients with differentiated thyroid cancer. |
format | Online Article Text |
id | pubmed-3626228 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-36262282013-04-19 Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody Ahn, Byeong-Cheol Lee, Won Kee Jeong, Shin Young Lee, Sang-Woo Lee, Jaetae Int J Endocrinol Research Article We investigated the analytical interference of antithyroglobulin antibody (TgAb) to thyroglobulin (Tg) measurement and tried to convert measured Tg concentration to true Tg concentration using a mathematical equation which includes a concentration of TgAb. Methods. Tg was measured by immunoradiometric assay and TgAb by radioimmunoassy. Experimental samples were produced by mixing Tg and TgAb standard solutions or mixing patients' serum with high Tg or high TgAb. Mathematical equations for prediction of expected Tg concentration with measured Tg and TgAb concentrations were deduced. The Tg concentration calculated using the equations was compared with the expected Tg concentration. Results. Measured Tg concentrations of samples having high TgAb were significantly lower than their expected Tg concentration. Magnitude of TgAb interference with the Tg assay showed a positive correlation with concentration of TgAb. Mathematical equations for estimation of expected Tg concentration using measured Tg and TgAb concentrations were successfully deduced and the calculated Tg concentration showed excellent correlation with expected Tg concentration. Conclusions. A mathematic equation for estimation of true Tg concentration using measured Tg and TgAb concentration was deduced. Tg concentration calculated by use of the equation might be more valuable than measured Tg concentration in patients with differentiated thyroid cancer. Hindawi Publishing Corporation 2013 2013-03-31 /pmc/articles/PMC3626228/ /pubmed/23606837 http://dx.doi.org/10.1155/2013/210639 Text en Copyright © 2013 Byeong-Cheol Ahn et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ahn, Byeong-Cheol Lee, Won Kee Jeong, Shin Young Lee, Sang-Woo Lee, Jaetae Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title | Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title_full | Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title_fullStr | Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title_full_unstemmed | Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title_short | Estimation of True Serum Thyroglobulin Concentration Using Simultaneous Measurement of Serum Antithyroglobulin Antibody |
title_sort | estimation of true serum thyroglobulin concentration using simultaneous measurement of serum antithyroglobulin antibody |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626228/ https://www.ncbi.nlm.nih.gov/pubmed/23606837 http://dx.doi.org/10.1155/2013/210639 |
work_keys_str_mv | AT ahnbyeongcheol estimationoftrueserumthyroglobulinconcentrationusingsimultaneousmeasurementofserumantithyroglobulinantibody AT leewonkee estimationoftrueserumthyroglobulinconcentrationusingsimultaneousmeasurementofserumantithyroglobulinantibody AT jeongshinyoung estimationoftrueserumthyroglobulinconcentrationusingsimultaneousmeasurementofserumantithyroglobulinantibody AT leesangwoo estimationoftrueserumthyroglobulinconcentrationusingsimultaneousmeasurementofserumantithyroglobulinantibody AT leejaetae estimationoftrueserumthyroglobulinconcentrationusingsimultaneousmeasurementofserumantithyroglobulinantibody |