Cargando…
Design and manufacture of a novel system to simulate the biomechanics of basic and pitching shoulder motion
OBJECTIVES: Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and cap...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
British Editorial Society of Bone and Joint Surgery
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626244/ https://www.ncbi.nlm.nih.gov/pubmed/23610675 http://dx.doi.org/10.1302/2046-3758.15.2000051 |
_version_ | 1782266173185851392 |
---|---|
author | Entezari, V. Trechsel, B. L. Dow, W. A. Stanton, S. K. Rosso, C. Müller, A. McKenzie, B. Vartanians, V. Cereatti, A. Della Croce, U. DeAngelis, J. P. Ramappa, A. J. Nazarian, A. |
author_facet | Entezari, V. Trechsel, B. L. Dow, W. A. Stanton, S. K. Rosso, C. Müller, A. McKenzie, B. Vartanians, V. Cereatti, A. Della Croce, U. DeAngelis, J. P. Ramappa, A. J. Nazarian, A. |
author_sort | Entezari, V. |
collection | PubMed |
description | OBJECTIVES: Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras. METHODS: In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector. RESULTS: The testing system demonstrated high precision and accuracy based on the expected versus observed displacements of individual axes. The maximum coefficient of variation for displacement of unloaded axes was less than 0.5% for all axes. The expected and observed actual displacements had a high level of correlation with coefficients of determination of 1.0 for all axes. CONCLUSIONS: Given that this system can accurately simulate and track simple and complex motion, there is a new opportunity to study kinematics of the shoulder under normal and pathological conditions in a cadaveric shoulder model. |
format | Online Article Text |
id | pubmed-3626244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | British Editorial Society of Bone and Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-36262442013-04-22 Design and manufacture of a novel system to simulate the biomechanics of basic and pitching shoulder motion Entezari, V. Trechsel, B. L. Dow, W. A. Stanton, S. K. Rosso, C. Müller, A. McKenzie, B. Vartanians, V. Cereatti, A. Della Croce, U. DeAngelis, J. P. Ramappa, A. J. Nazarian, A. Bone Joint Res Upper Limb OBJECTIVES: Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic system to accurately create three-dimensional movement of the upper body and capture it using high-speed motion cameras. METHODS: In particular, we intended to use the robotic system to simulate the normal throwing motion in an intact cadaver. The robotic system consists of a lower frame (to move the torso) and an upper frame (to move an arm) using seven actuators. The actuators accurately reproduced planned trajectories. The marker setup used for motion capture was able to determine the six degrees of freedom of all involved joints during the planned motion of the end effector. RESULTS: The testing system demonstrated high precision and accuracy based on the expected versus observed displacements of individual axes. The maximum coefficient of variation for displacement of unloaded axes was less than 0.5% for all axes. The expected and observed actual displacements had a high level of correlation with coefficients of determination of 1.0 for all axes. CONCLUSIONS: Given that this system can accurately simulate and track simple and complex motion, there is a new opportunity to study kinematics of the shoulder under normal and pathological conditions in a cadaveric shoulder model. British Editorial Society of Bone and Joint Surgery 2012-05-01 /pmc/articles/PMC3626244/ /pubmed/23610675 http://dx.doi.org/10.1302/2046-3758.15.2000051 Text en ©2012 British Editorial Society of Bone and Joint Surgery This is an open-access article distributed under the terms of the Creative Commons Attributions licence, which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Upper Limb Entezari, V. Trechsel, B. L. Dow, W. A. Stanton, S. K. Rosso, C. Müller, A. McKenzie, B. Vartanians, V. Cereatti, A. Della Croce, U. DeAngelis, J. P. Ramappa, A. J. Nazarian, A. Design and manufacture of a novel system to simulate the biomechanics of basic and pitching shoulder motion |
title | Design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
title_full | Design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
title_fullStr | Design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
title_full_unstemmed | Design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
title_short | Design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
title_sort | design and manufacture of a novel system
to simulate the biomechanics
of basic and pitching shoulder motion |
topic | Upper Limb |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626244/ https://www.ncbi.nlm.nih.gov/pubmed/23610675 http://dx.doi.org/10.1302/2046-3758.15.2000051 |
work_keys_str_mv | AT entezariv designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT trechselbl designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT dowwa designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT stantonsk designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT rossoc designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT mullera designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT mckenzieb designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT vartaniansv designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT cereattia designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT dellacroceu designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT deangelisjp designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT ramappaaj designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion AT nazariana designandmanufactureofanovelsystemtosimulatethebiomechanicsofbasicandpitchingshouldermotion |