Cargando…
Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
British Editorial Society of Bone and Joint Surgery
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626255/ https://www.ncbi.nlm.nih.gov/pubmed/23610657 http://dx.doi.org/10.1302/2046-3758.110.2000117 |
_version_ | 1782266175695093760 |
---|---|
author | Sharma, G. B. Saevarsson, S. K. Amiri, S. Montgomery, S. Ramm, H. Lichti, D. D. Lieck, R. Zachow, S. Anglin, C. |
author_facet | Sharma, G. B. Saevarsson, S. K. Amiri, S. Montgomery, S. Ramm, H. Lichti, D. D. Lieck, R. Zachow, S. Anglin, C. |
author_sort | Sharma, G. B. |
collection | PubMed |
description | OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. METHODS: A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. RESULTS: The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. CONCLUSIONS: The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design. |
format | Online Article Text |
id | pubmed-3626255 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | British Editorial Society of Bone and Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-36262552013-04-22 Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement Sharma, G. B. Saevarsson, S. K. Amiri, S. Montgomery, S. Ramm, H. Lichti, D. D. Lieck, R. Zachow, S. Anglin, C. Bone Joint Res Knee OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. METHODS: A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. RESULTS: The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. CONCLUSIONS: The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design. British Editorial Society of Bone and Joint Surgery 2012-10-01 /pmc/articles/PMC3626255/ /pubmed/23610657 http://dx.doi.org/10.1302/2046-3758.110.2000117 Text en This is an open-access article distributed under the terms of the Creative Commons Attributions licence, which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Knee Sharma, G. B. Saevarsson, S. K. Amiri, S. Montgomery, S. Ramm, H. Lichti, D. D. Lieck, R. Zachow, S. Anglin, C. Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement |
title | Radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
title_full | Radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
title_fullStr | Radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
title_full_unstemmed | Radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
title_short | Radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
title_sort | radiological method for measuring patellofemoral
tracking and tibiofemoral kinematics before and after total knee replacement |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626255/ https://www.ncbi.nlm.nih.gov/pubmed/23610657 http://dx.doi.org/10.1302/2046-3758.110.2000117 |
work_keys_str_mv | AT sharmagb radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT saevarssonsk radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT amiris radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT montgomerys radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT rammh radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT lichtidd radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT lieckr radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT zachows radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement AT anglinc radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement |