Cargando…

Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement

OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, G. B., Saevarsson, S. K., Amiri, S., Montgomery, S., Ramm, H., Lichti, D. D., Lieck, R., Zachow, S., Anglin, C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Editorial Society of Bone and Joint Surgery 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626255/
https://www.ncbi.nlm.nih.gov/pubmed/23610657
http://dx.doi.org/10.1302/2046-3758.110.2000117
_version_ 1782266175695093760
author Sharma, G. B.
Saevarsson, S. K.
Amiri, S.
Montgomery, S.
Ramm, H.
Lichti, D. D.
Lieck, R.
Zachow, S.
Anglin, C.
author_facet Sharma, G. B.
Saevarsson, S. K.
Amiri, S.
Montgomery, S.
Ramm, H.
Lichti, D. D.
Lieck, R.
Zachow, S.
Anglin, C.
author_sort Sharma, G. B.
collection PubMed
description OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. METHODS: A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. RESULTS: The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. CONCLUSIONS: The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design.
format Online
Article
Text
id pubmed-3626255
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher British Editorial Society of Bone and Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-36262552013-04-22 Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement Sharma, G. B. Saevarsson, S. K. Amiri, S. Montgomery, S. Ramm, H. Lichti, D. D. Lieck, R. Zachow, S. Anglin, C. Bone Joint Res Knee OBJECTIVES: Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. METHODS: A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. RESULTS: The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. CONCLUSIONS: The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design. British Editorial Society of Bone and Joint Surgery 2012-10-01 /pmc/articles/PMC3626255/ /pubmed/23610657 http://dx.doi.org/10.1302/2046-3758.110.2000117 Text en This is an open-access article distributed under the terms of the Creative Commons Attributions licence, which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Knee
Sharma, G. B.
Saevarsson, S. K.
Amiri, S.
Montgomery, S.
Ramm, H.
Lichti, D. D.
Lieck, R.
Zachow, S.
Anglin, C.
Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title_full Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title_fullStr Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title_full_unstemmed Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title_short Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
title_sort radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626255/
https://www.ncbi.nlm.nih.gov/pubmed/23610657
http://dx.doi.org/10.1302/2046-3758.110.2000117
work_keys_str_mv AT sharmagb radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT saevarssonsk radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT amiris radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT montgomerys radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT rammh radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT lichtidd radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT lieckr radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT zachows radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement
AT anglinc radiologicalmethodformeasuringpatellofemoraltrackingandtibiofemoralkinematicsbeforeandaftertotalkneereplacement