Cargando…

Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision

The aim of the study was to evaluate the mid-term clinical results and survivorship of a rotating-hinge knee prosthesis (LINK® Endo-Model) in difficult primary and complex revision situations. Results after primary implantation were compared with those of revision procedures. Forty-nine prostheses i...

Descripción completa

Detalles Bibliográficos
Autores principales: Efe, Turgay, Roessler, Philip P., Heyse, Thomas J., Hauk, Carsten, Pahrmann, Caroline, Getgood, Alan, Schmitt, Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626306/
https://www.ncbi.nlm.nih.gov/pubmed/23589763
http://dx.doi.org/10.4081/or.2012.e35
_version_ 1782266180504911872
author Efe, Turgay
Roessler, Philip P.
Heyse, Thomas J.
Hauk, Carsten
Pahrmann, Caroline
Getgood, Alan
Schmitt, Jan
author_facet Efe, Turgay
Roessler, Philip P.
Heyse, Thomas J.
Hauk, Carsten
Pahrmann, Caroline
Getgood, Alan
Schmitt, Jan
author_sort Efe, Turgay
collection PubMed
description The aim of the study was to evaluate the mid-term clinical results and survivorship of a rotating-hinge knee prosthesis (LINK® Endo-Model) in difficult primary and complex revision situations. Results after primary implantation were compared with those of revision procedures. Forty-nine prostheses in 45 patients were reviewed clinically during follow up. Twenty-one of these were implanted in primary and 28 in revision situations. Outcome was evaluated using commonly used scores (Knee Society, UCLA Activity, Lequesne) and a visual analog scale after a mean follow up of 56±37 months for 49 prostheses. Implant survival was analyzed using the Kaplan-Meier method. There were no significant differences in clinical examination and evaluation scores between the two groups (P>0.05). Survival rates at final follow up were 95% after primary implantation and 76% in revision procedures. The risk of prosthesis loss (odds ratio 5.7) was significantly higher after revision procedures (P=0.004). These data suggest that rotating-hinge knee prostheses provided good clinical and functional results in selected cases of advanced primary gonarthrosis associated with severe bone loss, ligamentous instability or comminuted fractures. They also provide good results in revision situations. However, the failure rate was significantly higher in cases of revision surgery.
format Online
Article
Text
id pubmed-3626306
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher PAGEPress Publications
record_format MEDLINE/PubMed
spelling pubmed-36263062013-04-15 Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision Efe, Turgay Roessler, Philip P. Heyse, Thomas J. Hauk, Carsten Pahrmann, Caroline Getgood, Alan Schmitt, Jan Orthop Rev (Pavia) Article The aim of the study was to evaluate the mid-term clinical results and survivorship of a rotating-hinge knee prosthesis (LINK® Endo-Model) in difficult primary and complex revision situations. Results after primary implantation were compared with those of revision procedures. Forty-nine prostheses in 45 patients were reviewed clinically during follow up. Twenty-one of these were implanted in primary and 28 in revision situations. Outcome was evaluated using commonly used scores (Knee Society, UCLA Activity, Lequesne) and a visual analog scale after a mean follow up of 56±37 months for 49 prostheses. Implant survival was analyzed using the Kaplan-Meier method. There were no significant differences in clinical examination and evaluation scores between the two groups (P>0.05). Survival rates at final follow up were 95% after primary implantation and 76% in revision procedures. The risk of prosthesis loss (odds ratio 5.7) was significantly higher after revision procedures (P=0.004). These data suggest that rotating-hinge knee prostheses provided good clinical and functional results in selected cases of advanced primary gonarthrosis associated with severe bone loss, ligamentous instability or comminuted fractures. They also provide good results in revision situations. However, the failure rate was significantly higher in cases of revision surgery. PAGEPress Publications 2012-12-11 /pmc/articles/PMC3626306/ /pubmed/23589763 http://dx.doi.org/10.4081/or.2012.e35 Text en ©Copyright T. Efe et al., 2012 This work is licensed under a Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0). Licensee PAGEPress, Italy
spellingShingle Article
Efe, Turgay
Roessler, Philip P.
Heyse, Thomas J.
Hauk, Carsten
Pahrmann, Caroline
Getgood, Alan
Schmitt, Jan
Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title_full Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title_fullStr Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title_full_unstemmed Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title_short Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
title_sort mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3626306/
https://www.ncbi.nlm.nih.gov/pubmed/23589763
http://dx.doi.org/10.4081/or.2012.e35
work_keys_str_mv AT efeturgay midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT roesslerphilipp midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT heysethomasj midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT haukcarsten midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT pahrmanncaroline midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT getgoodalan midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision
AT schmittjan midtermresultsafterimplantationofrotatinghingekneeprosthesesprimaryversusrevision