Cargando…

Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients

BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectivel...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Wen-Jing, Sun, Ying, Chi, Feng, Fang, Jian-Lan, Guo, Rui, Yu, Xiao-Li, Mao, Yan-Ping, Qi, Zhen-Yu, Guo, Ying, Liu, Meng-Zhong, Ma, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627906/
https://www.ncbi.nlm.nih.gov/pubmed/23547760
http://dx.doi.org/10.1186/1748-717X-8-78
_version_ 1782266354026414080
author Yin, Wen-Jing
Sun, Ying
Chi, Feng
Fang, Jian-Lan
Guo, Rui
Yu, Xiao-Li
Mao, Yan-Ping
Qi, Zhen-Yu
Guo, Ying
Liu, Meng-Zhong
Ma, Jun
author_facet Yin, Wen-Jing
Sun, Ying
Chi, Feng
Fang, Jian-Lan
Guo, Rui
Yu, Xiao-Li
Mao, Yan-Ping
Qi, Zhen-Yu
Guo, Ying
Liu, Meng-Zhong
Ma, Jun
author_sort Yin, Wen-Jing
collection PubMed
description BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectively guide treatment in the future. METHODS: Fifteen NPC patients scheduled to undergo VMAT were prospectively enrolled in the study. For each patient, three CBCT scans were obtained; one after daily conventional positioning, one after online correction with 2 mm tolerance and one after 1 week of VMAT delivery. The scans were registered to the planning CT to determine the inter- and intra-fraction errors. Patient positioning errors were analyzed for time trends over the course of radiotherapy. PTV margins were calculated from the systematic (Σ) and random (σ) errors. RESULTS: The average absolute values of the pre-correction, post-correction and intra-fraction errors (in order) were 1.1, 0.6 and 0.4 mm in the medial–lateral (ML) direction, 1.2, 0.7 and 0.5 mm in the superior–inferior (SI) direction and 1.1, 0.7 and 0.5 mm in the anterior–posterior (AP) direction. The corresponding Σ were 1.0–1.4 mm, 0.4–0.5 mm and 0.2–0.4 mm, while the corresponding σ were 0.7–0.8 mm, 0.6–0.7 mm and 0.5–0.6 mm. With time, gradual increases in both the inter- and intra-fraction three-dimensional displacements were observed (P = 0.019 and P = 0.044, respectively). The total PTV margins accounting for pre-correction and intra-fraction errors were 3.4–4.1 mm and those accounting for post-correction and intra-fraction errors were 1.7–2.2 mm. CONCLUSIONS: CBCT is an effective modality to evaluate and improve the accuracy of VMAT in NPC patients. Inter- and intra-fraction three-dimensional displacements increased as a function of time during the course of radiotherapy. In our institution, we recommend a PTV margin of 5 mm for NPC patients undergoing VMAT without CBCT and 3 mm for those treated with rigorous daily CBCT scans.
format Online
Article
Text
id pubmed-3627906
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-36279062013-04-18 Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients Yin, Wen-Jing Sun, Ying Chi, Feng Fang, Jian-Lan Guo, Rui Yu, Xiao-Li Mao, Yan-Ping Qi, Zhen-Yu Guo, Ying Liu, Meng-Zhong Ma, Jun Radiat Oncol Research BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectively guide treatment in the future. METHODS: Fifteen NPC patients scheduled to undergo VMAT were prospectively enrolled in the study. For each patient, three CBCT scans were obtained; one after daily conventional positioning, one after online correction with 2 mm tolerance and one after 1 week of VMAT delivery. The scans were registered to the planning CT to determine the inter- and intra-fraction errors. Patient positioning errors were analyzed for time trends over the course of radiotherapy. PTV margins were calculated from the systematic (Σ) and random (σ) errors. RESULTS: The average absolute values of the pre-correction, post-correction and intra-fraction errors (in order) were 1.1, 0.6 and 0.4 mm in the medial–lateral (ML) direction, 1.2, 0.7 and 0.5 mm in the superior–inferior (SI) direction and 1.1, 0.7 and 0.5 mm in the anterior–posterior (AP) direction. The corresponding Σ were 1.0–1.4 mm, 0.4–0.5 mm and 0.2–0.4 mm, while the corresponding σ were 0.7–0.8 mm, 0.6–0.7 mm and 0.5–0.6 mm. With time, gradual increases in both the inter- and intra-fraction three-dimensional displacements were observed (P = 0.019 and P = 0.044, respectively). The total PTV margins accounting for pre-correction and intra-fraction errors were 3.4–4.1 mm and those accounting for post-correction and intra-fraction errors were 1.7–2.2 mm. CONCLUSIONS: CBCT is an effective modality to evaluate and improve the accuracy of VMAT in NPC patients. Inter- and intra-fraction three-dimensional displacements increased as a function of time during the course of radiotherapy. In our institution, we recommend a PTV margin of 5 mm for NPC patients undergoing VMAT without CBCT and 3 mm for those treated with rigorous daily CBCT scans. BioMed Central 2013-04-02 /pmc/articles/PMC3627906/ /pubmed/23547760 http://dx.doi.org/10.1186/1748-717X-8-78 Text en Copyright © 2013 Yin et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Yin, Wen-Jing
Sun, Ying
Chi, Feng
Fang, Jian-Lan
Guo, Rui
Yu, Xiao-Li
Mao, Yan-Ping
Qi, Zhen-Yu
Guo, Ying
Liu, Meng-Zhong
Ma, Jun
Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title_full Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title_fullStr Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title_full_unstemmed Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title_short Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
title_sort evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627906/
https://www.ncbi.nlm.nih.gov/pubmed/23547760
http://dx.doi.org/10.1186/1748-717X-8-78
work_keys_str_mv AT yinwenjing evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT sunying evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT chifeng evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT fangjianlan evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT guorui evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT yuxiaoli evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT maoyanping evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT qizhenyu evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT guoying evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT liumengzhong evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients
AT majun evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients