Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients
BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectivel...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627906/ https://www.ncbi.nlm.nih.gov/pubmed/23547760 http://dx.doi.org/10.1186/1748-717X-8-78 |
_version_ | 1782266354026414080 |
---|---|
author | Yin, Wen-Jing Sun, Ying Chi, Feng Fang, Jian-Lan Guo, Rui Yu, Xiao-Li Mao, Yan-Ping Qi, Zhen-Yu Guo, Ying Liu, Meng-Zhong Ma, Jun |
author_facet | Yin, Wen-Jing Sun, Ying Chi, Feng Fang, Jian-Lan Guo, Rui Yu, Xiao-Li Mao, Yan-Ping Qi, Zhen-Yu Guo, Ying Liu, Meng-Zhong Ma, Jun |
author_sort | Yin, Wen-Jing |
collection | PubMed |
description | BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectively guide treatment in the future. METHODS: Fifteen NPC patients scheduled to undergo VMAT were prospectively enrolled in the study. For each patient, three CBCT scans were obtained; one after daily conventional positioning, one after online correction with 2 mm tolerance and one after 1 week of VMAT delivery. The scans were registered to the planning CT to determine the inter- and intra-fraction errors. Patient positioning errors were analyzed for time trends over the course of radiotherapy. PTV margins were calculated from the systematic (Σ) and random (σ) errors. RESULTS: The average absolute values of the pre-correction, post-correction and intra-fraction errors (in order) were 1.1, 0.6 and 0.4 mm in the medial–lateral (ML) direction, 1.2, 0.7 and 0.5 mm in the superior–inferior (SI) direction and 1.1, 0.7 and 0.5 mm in the anterior–posterior (AP) direction. The corresponding Σ were 1.0–1.4 mm, 0.4–0.5 mm and 0.2–0.4 mm, while the corresponding σ were 0.7–0.8 mm, 0.6–0.7 mm and 0.5–0.6 mm. With time, gradual increases in both the inter- and intra-fraction three-dimensional displacements were observed (P = 0.019 and P = 0.044, respectively). The total PTV margins accounting for pre-correction and intra-fraction errors were 3.4–4.1 mm and those accounting for post-correction and intra-fraction errors were 1.7–2.2 mm. CONCLUSIONS: CBCT is an effective modality to evaluate and improve the accuracy of VMAT in NPC patients. Inter- and intra-fraction three-dimensional displacements increased as a function of time during the course of radiotherapy. In our institution, we recommend a PTV margin of 5 mm for NPC patients undergoing VMAT without CBCT and 3 mm for those treated with rigorous daily CBCT scans. |
format | Online Article Text |
id | pubmed-3627906 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-36279062013-04-18 Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients Yin, Wen-Jing Sun, Ying Chi, Feng Fang, Jian-Lan Guo, Rui Yu, Xiao-Li Mao, Yan-Ping Qi, Zhen-Yu Guo, Ying Liu, Meng-Zhong Ma, Jun Radiat Oncol Research BACKGROUND: This prospective study was conducted to evaluate inter- and intra-fraction errors in nasopharyngeal carcinoma (NPC) patients undergoing volumetric modulated arc therapy (VMAT) using cone-beam computed tomography (CBCT) and to thus obtain planning target volume (PTV) margins to effectively guide treatment in the future. METHODS: Fifteen NPC patients scheduled to undergo VMAT were prospectively enrolled in the study. For each patient, three CBCT scans were obtained; one after daily conventional positioning, one after online correction with 2 mm tolerance and one after 1 week of VMAT delivery. The scans were registered to the planning CT to determine the inter- and intra-fraction errors. Patient positioning errors were analyzed for time trends over the course of radiotherapy. PTV margins were calculated from the systematic (Σ) and random (σ) errors. RESULTS: The average absolute values of the pre-correction, post-correction and intra-fraction errors (in order) were 1.1, 0.6 and 0.4 mm in the medial–lateral (ML) direction, 1.2, 0.7 and 0.5 mm in the superior–inferior (SI) direction and 1.1, 0.7 and 0.5 mm in the anterior–posterior (AP) direction. The corresponding Σ were 1.0–1.4 mm, 0.4–0.5 mm and 0.2–0.4 mm, while the corresponding σ were 0.7–0.8 mm, 0.6–0.7 mm and 0.5–0.6 mm. With time, gradual increases in both the inter- and intra-fraction three-dimensional displacements were observed (P = 0.019 and P = 0.044, respectively). The total PTV margins accounting for pre-correction and intra-fraction errors were 3.4–4.1 mm and those accounting for post-correction and intra-fraction errors were 1.7–2.2 mm. CONCLUSIONS: CBCT is an effective modality to evaluate and improve the accuracy of VMAT in NPC patients. Inter- and intra-fraction three-dimensional displacements increased as a function of time during the course of radiotherapy. In our institution, we recommend a PTV margin of 5 mm for NPC patients undergoing VMAT without CBCT and 3 mm for those treated with rigorous daily CBCT scans. BioMed Central 2013-04-02 /pmc/articles/PMC3627906/ /pubmed/23547760 http://dx.doi.org/10.1186/1748-717X-8-78 Text en Copyright © 2013 Yin et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Yin, Wen-Jing Sun, Ying Chi, Feng Fang, Jian-Lan Guo, Rui Yu, Xiao-Li Mao, Yan-Ping Qi, Zhen-Yu Guo, Ying Liu, Meng-Zhong Ma, Jun Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title | Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title_full | Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title_fullStr | Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title_full_unstemmed | Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title_short | Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
title_sort | evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3627906/ https://www.ncbi.nlm.nih.gov/pubmed/23547760 http://dx.doi.org/10.1186/1748-717X-8-78 |
work_keys_str_mv | AT yinwenjing evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT sunying evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT chifeng evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT fangjianlan evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT guorui evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT yuxiaoli evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT maoyanping evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT qizhenyu evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT guoying evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT liumengzhong evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients AT majun evaluationofinterfractionandintrafractionerrorsduringvolumetricmodulatedarctherapyinnasopharyngealcarcinomapatients |