Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair

Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, par...

Descripción completa

Detalles Bibliográficos
Autores principales: Hennecke, Kathleen, Redeker, Joern, Kuhbier, Joern W., Strauss, Sarah, Allmeling, Christina, Kasper, Cornelia, Reimers, Kerstin, Vogt, Peter M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3629086/
https://www.ncbi.nlm.nih.gov/pubmed/23613793
http://dx.doi.org/10.1371/journal.pone.0061100
_version_ 1782266516755972096
author Hennecke, Kathleen
Redeker, Joern
Kuhbier, Joern W.
Strauss, Sarah
Allmeling, Christina
Kasper, Cornelia
Reimers, Kerstin
Vogt, Peter M.
author_facet Hennecke, Kathleen
Redeker, Joern
Kuhbier, Joern W.
Strauss, Sarah
Allmeling, Christina
Kasper, Cornelia
Reimers, Kerstin
Vogt, Peter M.
author_sort Hennecke, Kathleen
collection PubMed
description Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.
format Online
Article
Text
id pubmed-3629086
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-36290862013-04-23 Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair Hennecke, Kathleen Redeker, Joern Kuhbier, Joern W. Strauss, Sarah Allmeling, Christina Kasper, Cornelia Reimers, Kerstin Vogt, Peter M. PLoS One Research Article Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. Public Library of Science 2013-04-17 /pmc/articles/PMC3629086/ /pubmed/23613793 http://dx.doi.org/10.1371/journal.pone.0061100 Text en © 2013 Hennecke et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hennecke, Kathleen
Redeker, Joern
Kuhbier, Joern W.
Strauss, Sarah
Allmeling, Christina
Kasper, Cornelia
Reimers, Kerstin
Vogt, Peter M.
Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title_full Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title_fullStr Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title_full_unstemmed Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title_short Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair
title_sort bundles of spider silk, braided into sutures, resist basic cyclic tests: potential use for flexor tendon repair
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3629086/
https://www.ncbi.nlm.nih.gov/pubmed/23613793
http://dx.doi.org/10.1371/journal.pone.0061100
work_keys_str_mv AT henneckekathleen bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT redekerjoern bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT kuhbierjoernw bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT strausssarah bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT allmelingchristina bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT kaspercornelia bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT reimerskerstin bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair
AT vogtpeterm bundlesofspidersilkbraidedintosuturesresistbasiccyclictestspotentialuseforflexortendonrepair