Cargando…

High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study

High-definition optical coherence tomography (HD-OCT) is a non-invasive technique for morphological investigation of tissue with cellular resolution filling the imaging gap between reflectance confocal microscopy and conventional optical coherence tomography. The aim of this study is first to correl...

Descripción completa

Detalles Bibliográficos
Autores principales: Boone, Marc, Norrenberg, Sarah, Jemec, Gregor, Del Marmol, Véronique
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3631312/
https://www.ncbi.nlm.nih.gov/pubmed/23291909
http://dx.doi.org/10.1007/s00403-012-1311-8
_version_ 1782266779452571648
author Boone, Marc
Norrenberg, Sarah
Jemec, Gregor
Del Marmol, Véronique
author_facet Boone, Marc
Norrenberg, Sarah
Jemec, Gregor
Del Marmol, Véronique
author_sort Boone, Marc
collection PubMed
description High-definition optical coherence tomography (HD-OCT) is a non-invasive technique for morphological investigation of tissue with cellular resolution filling the imaging gap between reflectance confocal microscopy and conventional optical coherence tomography. The aim of this study is first to correlate dermatopathologic descriptors of inflammatory skin conditions with epidermal alteration to features observed by HD-OCT. Secondly, to assess the discriminative accuracy of common inflammatory reaction patterns with epidermal alteration using HD-OCT by applying Ackerman’s algorithmic method of pattern recognition. The generated HD-OCT images of 160 patients presenting an inflammatory skin disease were analyzed with respect to the following criteria: visualization of individual cells in the epidermis and dermis and morphology of dermo-epidermal junction, papillary dermis and reticular dermis. A set of morphological features corresponding to dermatopathological descriptors are obtained and the discriminative accuracy of HD-OCT of inflammatory reaction patterns could be demonstrated. These patterns are spongiotic dermatitis, psoriasiform dermatitis, interface dermatitis and ballooning dermatitis. Additional studies to test the sensitivity and specificity of the proposed algorithm for pattern analysis are essential. The other categories of Ackerman’s pattern recognition need to be evaluated. This study provides a set of morphological features generated by HD-OCT imaging very similar to those described for reflectance confocal microscopy but with the advantages not only to visualize individual cells up to a depth of 570 μm but also in both slice and en face mode. An adapted algorithmic method for pattern analysis of common inflammatory skin diseases could be proposed. This new technique appears to be a promising method for non-invasive diagnosis, evaluation and management of common inflammatory skin diseases.
format Online
Article
Text
id pubmed-3631312
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-36313122013-04-25 High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study Boone, Marc Norrenberg, Sarah Jemec, Gregor Del Marmol, Véronique Arch Dermatol Res Original Paper High-definition optical coherence tomography (HD-OCT) is a non-invasive technique for morphological investigation of tissue with cellular resolution filling the imaging gap between reflectance confocal microscopy and conventional optical coherence tomography. The aim of this study is first to correlate dermatopathologic descriptors of inflammatory skin conditions with epidermal alteration to features observed by HD-OCT. Secondly, to assess the discriminative accuracy of common inflammatory reaction patterns with epidermal alteration using HD-OCT by applying Ackerman’s algorithmic method of pattern recognition. The generated HD-OCT images of 160 patients presenting an inflammatory skin disease were analyzed with respect to the following criteria: visualization of individual cells in the epidermis and dermis and morphology of dermo-epidermal junction, papillary dermis and reticular dermis. A set of morphological features corresponding to dermatopathological descriptors are obtained and the discriminative accuracy of HD-OCT of inflammatory reaction patterns could be demonstrated. These patterns are spongiotic dermatitis, psoriasiform dermatitis, interface dermatitis and ballooning dermatitis. Additional studies to test the sensitivity and specificity of the proposed algorithm for pattern analysis are essential. The other categories of Ackerman’s pattern recognition need to be evaluated. This study provides a set of morphological features generated by HD-OCT imaging very similar to those described for reflectance confocal microscopy but with the advantages not only to visualize individual cells up to a depth of 570 μm but also in both slice and en face mode. An adapted algorithmic method for pattern analysis of common inflammatory skin diseases could be proposed. This new technique appears to be a promising method for non-invasive diagnosis, evaluation and management of common inflammatory skin diseases. Springer-Verlag 2013-01-06 2013 /pmc/articles/PMC3631312/ /pubmed/23291909 http://dx.doi.org/10.1007/s00403-012-1311-8 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Paper
Boone, Marc
Norrenberg, Sarah
Jemec, Gregor
Del Marmol, Véronique
High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title_full High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title_fullStr High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title_full_unstemmed High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title_short High-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
title_sort high-definition optical coherence tomography: adapted algorithmic method for pattern analysis of inflammatory skin diseases: a pilot study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3631312/
https://www.ncbi.nlm.nih.gov/pubmed/23291909
http://dx.doi.org/10.1007/s00403-012-1311-8
work_keys_str_mv AT boonemarc highdefinitionopticalcoherencetomographyadaptedalgorithmicmethodforpatternanalysisofinflammatoryskindiseasesapilotstudy
AT norrenbergsarah highdefinitionopticalcoherencetomographyadaptedalgorithmicmethodforpatternanalysisofinflammatoryskindiseasesapilotstudy
AT jemecgregor highdefinitionopticalcoherencetomographyadaptedalgorithmicmethodforpatternanalysisofinflammatoryskindiseasesapilotstudy
AT delmarmolveronique highdefinitionopticalcoherencetomographyadaptedalgorithmicmethodforpatternanalysisofinflammatoryskindiseasesapilotstudy