Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla
This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B(0)≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receiv...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632575/ https://www.ncbi.nlm.nih.gov/pubmed/23613896 http://dx.doi.org/10.1371/journal.pone.0061661 |
_version_ | 1782266883165126656 |
---|---|
author | Winter, Lukas Özerdem, Celal Hoffmann, Werner Santoro, Davide Müller, Alexander Waiczies, Helmar Seemann, Reiner Graessl, Andreas Wust, Peter Niendorf, Thoralf |
author_facet | Winter, Lukas Özerdem, Celal Hoffmann, Werner Santoro, Davide Müller, Alexander Waiczies, Helmar Seemann, Reiner Graessl, Andreas Wust, Peter Niendorf, Thoralf |
author_sort | Winter, Lukas |
collection | PubMed |
description | This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B(0)≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B(0) = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B(0) which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device. |
format | Online Article Text |
id | pubmed-3632575 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-36325752013-04-23 Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla Winter, Lukas Özerdem, Celal Hoffmann, Werner Santoro, Davide Müller, Alexander Waiczies, Helmar Seemann, Reiner Graessl, Andreas Wust, Peter Niendorf, Thoralf PLoS One Research Article This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B(0)≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B(0) = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B(0) which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device. Public Library of Science 2013-04-22 /pmc/articles/PMC3632575/ /pubmed/23613896 http://dx.doi.org/10.1371/journal.pone.0061661 Text en © 2013 Winter et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Winter, Lukas Özerdem, Celal Hoffmann, Werner Santoro, Davide Müller, Alexander Waiczies, Helmar Seemann, Reiner Graessl, Andreas Wust, Peter Niendorf, Thoralf Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title | Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title_full | Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title_fullStr | Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title_full_unstemmed | Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title_short | Design and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla |
title_sort | design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and rf induced hyperthermia: electromagnetic field simulations up to 14.0 tesla and proof-of-concept at 7.0 tesla |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632575/ https://www.ncbi.nlm.nih.gov/pubmed/23613896 http://dx.doi.org/10.1371/journal.pone.0061661 |
work_keys_str_mv | AT winterlukas designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT ozerdemcelal designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT hoffmannwerner designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT santorodavide designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT mulleralexander designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT waiczieshelmar designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT seemannreiner designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT graesslandreas designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT wustpeter designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla AT niendorfthoralf designandevaluationofahybridradiofrequencyapplicatorformagneticresonanceimagingandrfinducedhyperthermiaelectromagneticfieldsimulationsupto140teslaandproofofconceptat70tesla |