Cargando…
Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632584/ https://www.ncbi.nlm.nih.gov/pubmed/23626466 http://dx.doi.org/10.2147/IJN.S33589 |
_version_ | 1782266885231869952 |
---|---|
author | Giri, Shibashish Braumann, Ulf-Dietrich Giri, Priya Acikgöz, Ali Scheibe, Patrick Nieber, Karen Bader, Augustinus |
author_facet | Giri, Shibashish Braumann, Ulf-Dietrich Giri, Priya Acikgöz, Ali Scheibe, Patrick Nieber, Karen Bader, Augustinus |
author_sort | Giri, Shibashish |
collection | PubMed |
description | Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative approaches for the functional maintenance of primary hepatocytes. However, none of the above methods meet US Food and Drug Administration (FDA) guidelines, which recommend and encourage that the duration of a toxicity assay of a drug should be a minimum of 14 days, to a maximum of 90 days for a general toxicity assay. Existing innovative reports have used undefined extracellular matrices like matrigel, rigid collagen, or serum supplementations, which are often problematic, unacceptable in preclinical and clinical applications, and can even interfere with experimental outcomes. We have overcome these challenges by using integrated nanostructured self-assembling peptides and a special combination of growth factors and cytokines to establish a proof of concept to mimic the in vivo hepatocyte microenvironment pattern in vitro for predicting the in vivo drug hepatotoxicity in a scalable bioartificial liver module. Hepatocyte functionality (albumin, urea) was measured at days 10, 30, 60, and 90 and we observed stable albumin secretion and urea function throughout the culture period. In parallel, drug metabolizing enzyme biomarkers such as ethoxyresorufin-O-deethylase, the methylthiazol tetrazolium test, and the lactate dehydrogenase test were carried out at days 10, 30, 60, and 90. We noticed excellent mitochondrial status and membrane stability at 90 days of culture. Since alpha glutathione S-transferase (GST) is highly sensitive and a specific marker of hepatocyte injury, we observed significantly low alpha GST levels on all measured days (10, 30, 60, and 90). Finally, we performed the image analysis of mitochondria-cultured hepatocytes at day 90 in different biophysical parameters using confocal microscopy. We applied an automatic algorithm-based method for 3D visualization to show the classic representation of the mitochondrial distribution in double hepatocytes. An automated morphological measurement was conducted on the mitochondrial distribution in the cultured hepatocytes. Our proof of concept of a scalable bioartificial liver modular device meets FDA guidelines and may function as an alternative model of animal experimentation for pharmacological and toxicological studies involving drug metabolism, enzyme induction, transplantation, viral hepatitis, hepatocyte regeneration, and can also be used in other existing bioreactor modules for long-term culture for up to 90 days or more. |
format | Online Article Text |
id | pubmed-3632584 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-36325842013-04-26 Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device Giri, Shibashish Braumann, Ulf-Dietrich Giri, Priya Acikgöz, Ali Scheibe, Patrick Nieber, Karen Bader, Augustinus Int J Nanomedicine Original Research Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative approaches for the functional maintenance of primary hepatocytes. However, none of the above methods meet US Food and Drug Administration (FDA) guidelines, which recommend and encourage that the duration of a toxicity assay of a drug should be a minimum of 14 days, to a maximum of 90 days for a general toxicity assay. Existing innovative reports have used undefined extracellular matrices like matrigel, rigid collagen, or serum supplementations, which are often problematic, unacceptable in preclinical and clinical applications, and can even interfere with experimental outcomes. We have overcome these challenges by using integrated nanostructured self-assembling peptides and a special combination of growth factors and cytokines to establish a proof of concept to mimic the in vivo hepatocyte microenvironment pattern in vitro for predicting the in vivo drug hepatotoxicity in a scalable bioartificial liver module. Hepatocyte functionality (albumin, urea) was measured at days 10, 30, 60, and 90 and we observed stable albumin secretion and urea function throughout the culture period. In parallel, drug metabolizing enzyme biomarkers such as ethoxyresorufin-O-deethylase, the methylthiazol tetrazolium test, and the lactate dehydrogenase test were carried out at days 10, 30, 60, and 90. We noticed excellent mitochondrial status and membrane stability at 90 days of culture. Since alpha glutathione S-transferase (GST) is highly sensitive and a specific marker of hepatocyte injury, we observed significantly low alpha GST levels on all measured days (10, 30, 60, and 90). Finally, we performed the image analysis of mitochondria-cultured hepatocytes at day 90 in different biophysical parameters using confocal microscopy. We applied an automatic algorithm-based method for 3D visualization to show the classic representation of the mitochondrial distribution in double hepatocytes. An automated morphological measurement was conducted on the mitochondrial distribution in the cultured hepatocytes. Our proof of concept of a scalable bioartificial liver modular device meets FDA guidelines and may function as an alternative model of animal experimentation for pharmacological and toxicological studies involving drug metabolism, enzyme induction, transplantation, viral hepatitis, hepatocyte regeneration, and can also be used in other existing bioreactor modules for long-term culture for up to 90 days or more. Dove Medical Press 2013 2013-04-18 /pmc/articles/PMC3632584/ /pubmed/23626466 http://dx.doi.org/10.2147/IJN.S33589 Text en © 2013 Giri et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Giri, Shibashish Braumann, Ulf-Dietrich Giri, Priya Acikgöz, Ali Scheibe, Patrick Nieber, Karen Bader, Augustinus Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title | Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title_full | Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title_fullStr | Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title_full_unstemmed | Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title_short | Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
title_sort | nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632584/ https://www.ncbi.nlm.nih.gov/pubmed/23626466 http://dx.doi.org/10.2147/IJN.S33589 |
work_keys_str_mv | AT girishibashish nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT braumannulfdietrich nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT giripriya nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT acikgozali nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT scheibepatrick nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT nieberkaren nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice AT baderaugustinus nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice |