Cargando…

Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device

Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative...

Descripción completa

Detalles Bibliográficos
Autores principales: Giri, Shibashish, Braumann, Ulf-Dietrich, Giri, Priya, Acikgöz, Ali, Scheibe, Patrick, Nieber, Karen, Bader, Augustinus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632584/
https://www.ncbi.nlm.nih.gov/pubmed/23626466
http://dx.doi.org/10.2147/IJN.S33589
_version_ 1782266885231869952
author Giri, Shibashish
Braumann, Ulf-Dietrich
Giri, Priya
Acikgöz, Ali
Scheibe, Patrick
Nieber, Karen
Bader, Augustinus
author_facet Giri, Shibashish
Braumann, Ulf-Dietrich
Giri, Priya
Acikgöz, Ali
Scheibe, Patrick
Nieber, Karen
Bader, Augustinus
author_sort Giri, Shibashish
collection PubMed
description Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative approaches for the functional maintenance of primary hepatocytes. However, none of the above methods meet US Food and Drug Administration (FDA) guidelines, which recommend and encourage that the duration of a toxicity assay of a drug should be a minimum of 14 days, to a maximum of 90 days for a general toxicity assay. Existing innovative reports have used undefined extracellular matrices like matrigel, rigid collagen, or serum supplementations, which are often problematic, unacceptable in preclinical and clinical applications, and can even interfere with experimental outcomes. We have overcome these challenges by using integrated nanostructured self-assembling peptides and a special combination of growth factors and cytokines to establish a proof of concept to mimic the in vivo hepatocyte microenvironment pattern in vitro for predicting the in vivo drug hepatotoxicity in a scalable bioartificial liver module. Hepatocyte functionality (albumin, urea) was measured at days 10, 30, 60, and 90 and we observed stable albumin secretion and urea function throughout the culture period. In parallel, drug metabolizing enzyme biomarkers such as ethoxyresorufin-O-deethylase, the methylthiazol tetrazolium test, and the lactate dehydrogenase test were carried out at days 10, 30, 60, and 90. We noticed excellent mitochondrial status and membrane stability at 90 days of culture. Since alpha glutathione S-transferase (GST) is highly sensitive and a specific marker of hepatocyte injury, we observed significantly low alpha GST levels on all measured days (10, 30, 60, and 90). Finally, we performed the image analysis of mitochondria-cultured hepatocytes at day 90 in different biophysical parameters using confocal microscopy. We applied an automatic algorithm-based method for 3D visualization to show the classic representation of the mitochondrial distribution in double hepatocytes. An automated morphological measurement was conducted on the mitochondrial distribution in the cultured hepatocytes. Our proof of concept of a scalable bioartificial liver modular device meets FDA guidelines and may function as an alternative model of animal experimentation for pharmacological and toxicological studies involving drug metabolism, enzyme induction, transplantation, viral hepatitis, hepatocyte regeneration, and can also be used in other existing bioreactor modules for long-term culture for up to 90 days or more.
format Online
Article
Text
id pubmed-3632584
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-36325842013-04-26 Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device Giri, Shibashish Braumann, Ulf-Dietrich Giri, Priya Acikgöz, Ali Scheibe, Patrick Nieber, Karen Bader, Augustinus Int J Nanomedicine Original Research Much effort has been directed towards the optimization of the capture of in vivo hepatocytes from their microenvironment. Some methods of capture include an ex vivo cellular model in a bioreactor based liver module, a micropatterned module, a microfluidic 3D chip, coated plates, and other innovative approaches for the functional maintenance of primary hepatocytes. However, none of the above methods meet US Food and Drug Administration (FDA) guidelines, which recommend and encourage that the duration of a toxicity assay of a drug should be a minimum of 14 days, to a maximum of 90 days for a general toxicity assay. Existing innovative reports have used undefined extracellular matrices like matrigel, rigid collagen, or serum supplementations, which are often problematic, unacceptable in preclinical and clinical applications, and can even interfere with experimental outcomes. We have overcome these challenges by using integrated nanostructured self-assembling peptides and a special combination of growth factors and cytokines to establish a proof of concept to mimic the in vivo hepatocyte microenvironment pattern in vitro for predicting the in vivo drug hepatotoxicity in a scalable bioartificial liver module. Hepatocyte functionality (albumin, urea) was measured at days 10, 30, 60, and 90 and we observed stable albumin secretion and urea function throughout the culture period. In parallel, drug metabolizing enzyme biomarkers such as ethoxyresorufin-O-deethylase, the methylthiazol tetrazolium test, and the lactate dehydrogenase test were carried out at days 10, 30, 60, and 90. We noticed excellent mitochondrial status and membrane stability at 90 days of culture. Since alpha glutathione S-transferase (GST) is highly sensitive and a specific marker of hepatocyte injury, we observed significantly low alpha GST levels on all measured days (10, 30, 60, and 90). Finally, we performed the image analysis of mitochondria-cultured hepatocytes at day 90 in different biophysical parameters using confocal microscopy. We applied an automatic algorithm-based method for 3D visualization to show the classic representation of the mitochondrial distribution in double hepatocytes. An automated morphological measurement was conducted on the mitochondrial distribution in the cultured hepatocytes. Our proof of concept of a scalable bioartificial liver modular device meets FDA guidelines and may function as an alternative model of animal experimentation for pharmacological and toxicological studies involving drug metabolism, enzyme induction, transplantation, viral hepatitis, hepatocyte regeneration, and can also be used in other existing bioreactor modules for long-term culture for up to 90 days or more. Dove Medical Press 2013 2013-04-18 /pmc/articles/PMC3632584/ /pubmed/23626466 http://dx.doi.org/10.2147/IJN.S33589 Text en © 2013 Giri et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Giri, Shibashish
Braumann, Ulf-Dietrich
Giri, Priya
Acikgöz, Ali
Scheibe, Patrick
Nieber, Karen
Bader, Augustinus
Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title_full Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title_fullStr Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title_full_unstemmed Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title_short Nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
title_sort nanostructured self-assembling peptides as a defined extracellular matrix for long-term functional maintenance of primary hepatocytes in a bioartificial liver modular device
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3632584/
https://www.ncbi.nlm.nih.gov/pubmed/23626466
http://dx.doi.org/10.2147/IJN.S33589
work_keys_str_mv AT girishibashish nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT braumannulfdietrich nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT giripriya nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT acikgozali nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT scheibepatrick nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT nieberkaren nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice
AT baderaugustinus nanostructuredselfassemblingpeptidesasadefinedextracellularmatrixforlongtermfunctionalmaintenanceofprimaryhepatocytesinabioartificiallivermodulardevice