A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery

BACKGROUND: The aim of this study was to evaluate intraocular pressure (IOP) and hemodynamic responses following insertion of laryngeal mask airway (LMA) or endotracheal tube (ETT) after anesthesia induction with propofol and remifentanil in cataract surgery. MATERIALS AND METHODS: In a randomized c...

Descripción completa

Detalles Bibliográficos
Autores principales: Ziyaeifard, Mohsen, Azarfarin, Rasoul, Massoumi, Gholamreza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3634284/
https://www.ncbi.nlm.nih.gov/pubmed/23626623
_version_ 1782267087446605824
author Ziyaeifard, Mohsen
Azarfarin, Rasoul
Massoumi, Gholamreza
author_facet Ziyaeifard, Mohsen
Azarfarin, Rasoul
Massoumi, Gholamreza
author_sort Ziyaeifard, Mohsen
collection PubMed
description BACKGROUND: The aim of this study was to evaluate intraocular pressure (IOP) and hemodynamic responses following insertion of laryngeal mask airway (LMA) or endotracheal tube (ETT) after anesthesia induction with propofol and remifentanil in cataract surgery. MATERIALS AND METHODS: In a randomized controlled study, 50 adults scheduled for elective cataract extraction procedure under general anesthesia were allocated to LMA insertion (n = 25) or ETT (n = 25) groups. IOP, systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) were measured after insertion of the airway device every minute up to 5 min. RESULTS: There were no significant differences between LMA and ETT groups in SBP, DBP, HR, and IOP immediately after airway instrumentation up to 5 min, except in 4th min in DBP, 2nd min in HR, and 5th min in IOP (7.9 ± 2.3 mmHg in LMA and 9.4 ± 2.5 mmHg in ETT group; P = 0.030). There was good surgeon satisfaction for providing acceptable surgical field in both groups (88% in LMA and 80% in ETT group; P = 0.702). CONCLUSION: Propofol combined with remifentanil provides good and excellent conditions for insertion of LMA or ETT with minimal hemodynamic disturbances in cataract surgery. Considering LMA insertion is less traumatic than ETT, using LMA may be better than ETT for airway securing in these patients.
format Online
Article
Text
id pubmed-3634284
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36342842013-04-26 A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery Ziyaeifard, Mohsen Azarfarin, Rasoul Massoumi, Gholamreza J Res Med Sci Original Article BACKGROUND: The aim of this study was to evaluate intraocular pressure (IOP) and hemodynamic responses following insertion of laryngeal mask airway (LMA) or endotracheal tube (ETT) after anesthesia induction with propofol and remifentanil in cataract surgery. MATERIALS AND METHODS: In a randomized controlled study, 50 adults scheduled for elective cataract extraction procedure under general anesthesia were allocated to LMA insertion (n = 25) or ETT (n = 25) groups. IOP, systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) were measured after insertion of the airway device every minute up to 5 min. RESULTS: There were no significant differences between LMA and ETT groups in SBP, DBP, HR, and IOP immediately after airway instrumentation up to 5 min, except in 4th min in DBP, 2nd min in HR, and 5th min in IOP (7.9 ± 2.3 mmHg in LMA and 9.4 ± 2.5 mmHg in ETT group; P = 0.030). There was good surgeon satisfaction for providing acceptable surgical field in both groups (88% in LMA and 80% in ETT group; P = 0.702). CONCLUSION: Propofol combined with remifentanil provides good and excellent conditions for insertion of LMA or ETT with minimal hemodynamic disturbances in cataract surgery. Considering LMA insertion is less traumatic than ETT, using LMA may be better than ETT for airway securing in these patients. Medknow Publications & Media Pvt Ltd 2012-06 /pmc/articles/PMC3634284/ /pubmed/23626623 Text en Copyright: © Journal of Research in Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ziyaeifard, Mohsen
Azarfarin, Rasoul
Massoumi, Gholamreza
A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title_full A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title_fullStr A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title_full_unstemmed A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title_short A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
title_sort comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3634284/
https://www.ncbi.nlm.nih.gov/pubmed/23626623
work_keys_str_mv AT ziyaeifardmohsen acomparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery
AT azarfarinrasoul acomparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery
AT massoumigholamreza acomparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery
AT ziyaeifardmohsen comparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery
AT azarfarinrasoul comparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery
AT massoumigholamreza comparisonofintraocularpressureandhemodynamicresponsestoinsertionoflaryngealmaskairwayorendotrachealtubeusinganesthesiawithpropofolandremifentanilincataractsurgery