Cargando…

Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

PURPOSE: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to d...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Jong-Keon, Hwang, Jin-Ho, Varte, Lalrinliana, Ko, Jae-Han, Oh, Chang-Wug, Jung, Duk-Young, An, Hyonggin, Cho, Jae-Woo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3635637/
https://www.ncbi.nlm.nih.gov/pubmed/23549821
http://dx.doi.org/10.3349/ymj.2013.54.3.720
_version_ 1782267211617927168
author Oh, Jong-Keon
Hwang, Jin-Ho
Varte, Lalrinliana
Ko, Jae-Han
Oh, Chang-Wug
Jung, Duk-Young
An, Hyonggin
Cho, Jae-Woo
author_facet Oh, Jong-Keon
Hwang, Jin-Ho
Varte, Lalrinliana
Ko, Jae-Han
Oh, Chang-Wug
Jung, Duk-Young
An, Hyonggin
Cho, Jae-Woo
author_sort Oh, Jong-Keon
collection PubMed
description PURPOSE: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to determine normal alignment of the tibia in the coronal plane. MATERIALS AND METHODS: There are two parts to this study: in the first part, LCP PLT was applied to 30 cadaveric adult tibia. The angle between the joint line and the proximal most screw was measured and termed as the 'joint screw angle' (JSA). In the second part, 56 proximal tibial fractures treated with LCP PLT were retrospectively studied. Two angles were measured on the radiographs, the medial proximal tibial angle (MPTA) and the JSA. Their relationship was analyzed statistically. RESULTS: The average JSA was 1.16 degrees in the anatomical study. Statistical analysis of the clinical study showed that the normal MPTA had a direct correlation with an acceptable JSA. CONCLUSION: We therefore conclude that the JSA can be used intraoperatively to assess the achievement of a normal coronal axis.
format Online
Article
Text
id pubmed-3635637
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-36356372013-05-02 Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle Oh, Jong-Keon Hwang, Jin-Ho Varte, Lalrinliana Ko, Jae-Han Oh, Chang-Wug Jung, Duk-Young An, Hyonggin Cho, Jae-Woo Yonsei Med J Original Article PURPOSE: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to determine normal alignment of the tibia in the coronal plane. MATERIALS AND METHODS: There are two parts to this study: in the first part, LCP PLT was applied to 30 cadaveric adult tibia. The angle between the joint line and the proximal most screw was measured and termed as the 'joint screw angle' (JSA). In the second part, 56 proximal tibial fractures treated with LCP PLT were retrospectively studied. Two angles were measured on the radiographs, the medial proximal tibial angle (MPTA) and the JSA. Their relationship was analyzed statistically. RESULTS: The average JSA was 1.16 degrees in the anatomical study. Statistical analysis of the clinical study showed that the normal MPTA had a direct correlation with an acceptable JSA. CONCLUSION: We therefore conclude that the JSA can be used intraoperatively to assess the achievement of a normal coronal axis. Yonsei University College of Medicine 2013-05-01 2013-03-19 /pmc/articles/PMC3635637/ /pubmed/23549821 http://dx.doi.org/10.3349/ymj.2013.54.3.720 Text en © Copyright: Yonsei University College of Medicine 2013 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Oh, Jong-Keon
Hwang, Jin-Ho
Varte, Lalrinliana
Ko, Jae-Han
Oh, Chang-Wug
Jung, Duk-Young
An, Hyonggin
Cho, Jae-Woo
Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title_full Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title_fullStr Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title_full_unstemmed Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title_short Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle
title_sort locking plate in proximal tibial fracture: a correlation between the coronal alignment of tibia and joint screw angle
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3635637/
https://www.ncbi.nlm.nih.gov/pubmed/23549821
http://dx.doi.org/10.3349/ymj.2013.54.3.720
work_keys_str_mv AT ohjongkeon lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT hwangjinho lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT vartelalrinliana lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT kojaehan lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT ohchangwug lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT jungdukyoung lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT anhyonggin lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle
AT chojaewoo lockingplateinproximaltibialfractureacorrelationbetweenthecoronalalignmentoftibiaandjointscrewangle