False Femoral Neck Fracture Detected during Shaft Nailing: A Mach Band Effect

Femoral neck fractures are associated with femoral shaft fractures in 1% to 9% of cases. Undisplaced neck fractures are susceptible to displacement during shaft nailing. We report the case of a 57-year-old male patient in whom we performed standard intramedullary nailing for a femoral shaft fracture...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Kyu Hyun, Kim, Sungjun, Jeong, Ji Do
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3635655/
https://www.ncbi.nlm.nih.gov/pubmed/23549835
http://dx.doi.org/10.3349/ymj.2013.54.3.803
Descripción
Sumario:Femoral neck fractures are associated with femoral shaft fractures in 1% to 9% of cases. Undisplaced neck fractures are susceptible to displacement during shaft nailing. We report the case of a 57-year-old male patient in whom we performed standard intramedullary nailing for a femoral shaft fracture. In doing so, we identified a vertical radiolucent line at the femoral neck, which was thought to be further displacement of a hidden silent fracture or an iatrogenic fracture that developed during nail insertion. Consequently, we decided to switch to reconstructive femoral nailing. Postoperative hip imaging failed to show the femoral neck fracture that we saw in the operating room. Here, we discuss the aforementioned case and review the literature concerning this artifact.