False Femoral Neck Fracture Detected during Shaft Nailing: A Mach Band Effect
Femoral neck fractures are associated with femoral shaft fractures in 1% to 9% of cases. Undisplaced neck fractures are susceptible to displacement during shaft nailing. We report the case of a 57-year-old male patient in whom we performed standard intramedullary nailing for a femoral shaft fracture...
Autores principales: | Yang, Kyu Hyun, Kim, Sungjun, Jeong, Ji Do |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3635655/ https://www.ncbi.nlm.nih.gov/pubmed/23549835 http://dx.doi.org/10.3349/ymj.2013.54.3.803 |
Ejemplares similares
-
Reconstruction nailing for ipsilateral femoral neck and shaft fractures
por: Tsarouhas, Alexandros, et al.
Publicado: (2011) -
Use of Huckstep nail in the periimplant femoral shaft fracture
por: Kim, Hong Kyun, et al.
Publicado: (2012) -
Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture
por: Yun, Ho Hyun, et al.
Publicado: (2013) -
Intramedullary nailing of femoral and tibial shaft fractures
por: Wood, George W.
Publicado: (2006) -
Outcomes of Ipsilateral Femoral Neck and Shaft Fractures Treated With Proximal Femoral Nail Antirotation 2
por: Rana, Rajesh, et al.
Publicado: (2021)