Cargando…

Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis

BACKGROUND: Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE: The aim of this research was to determine the measurement error of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Masalski, Marcin, Kręcicki, Tomasz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications Inc. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636315/
https://www.ncbi.nlm.nih.gov/pubmed/23583917
http://dx.doi.org/10.2196/jmir.2222
_version_ 1782267315271761920
author Masalski, Marcin
Kręcicki, Tomasz
author_facet Masalski, Marcin
Kręcicki, Tomasz
author_sort Masalski, Marcin
collection PubMed
description BACKGROUND: Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE: The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors influencing its value. METHODS: The evaluation of the hearing threshold was made in three series: (1) tests on a clinical audiometer, (2) self-tests done on a specially calibrated computer under the supervision of an audiologist, and (3) self-tests conducted at home. The research was carried out on the group of 51 participants selected from patients of an audiology outpatient clinic. From the group of 51 patients examined in the first two series, the third series was self-administered at home by 37 subjects (73%). RESULTS: The average difference between the value of the hearing threshold determined in series 1 and in series 2 was -1.54dB with standard deviation of 7.88dB and a Pearson correlation coefficient of .90. Between the first and third series, these values were -1.35dB±10.66dB and .84, respectively. In series 3, the standard deviation was most influenced by the error connected with the procedure of hearing threshold identification (6.64dB), calibration error (6.19dB), and additionally at the frequency of 250Hz by frequency nonlinearity error (7.28dB). CONCLUSIONS: The obtained results confirm the possibility of applying Web-based pure-tone audiometry in screening tests. In the future, modifications of the method leading to the decrease in measurement error can broaden the scope of Web-based pure-tone audiometry application.
format Online
Article
Text
id pubmed-3636315
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher JMIR Publications Inc.
record_format MEDLINE/PubMed
spelling pubmed-36363152013-04-26 Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis Masalski, Marcin Kręcicki, Tomasz J Med Internet Res Original Paper BACKGROUND: Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE: The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors influencing its value. METHODS: The evaluation of the hearing threshold was made in three series: (1) tests on a clinical audiometer, (2) self-tests done on a specially calibrated computer under the supervision of an audiologist, and (3) self-tests conducted at home. The research was carried out on the group of 51 participants selected from patients of an audiology outpatient clinic. From the group of 51 patients examined in the first two series, the third series was self-administered at home by 37 subjects (73%). RESULTS: The average difference between the value of the hearing threshold determined in series 1 and in series 2 was -1.54dB with standard deviation of 7.88dB and a Pearson correlation coefficient of .90. Between the first and third series, these values were -1.35dB±10.66dB and .84, respectively. In series 3, the standard deviation was most influenced by the error connected with the procedure of hearing threshold identification (6.64dB), calibration error (6.19dB), and additionally at the frequency of 250Hz by frequency nonlinearity error (7.28dB). CONCLUSIONS: The obtained results confirm the possibility of applying Web-based pure-tone audiometry in screening tests. In the future, modifications of the method leading to the decrease in measurement error can broaden the scope of Web-based pure-tone audiometry application. JMIR Publications Inc. 2013-04-12 /pmc/articles/PMC3636315/ /pubmed/23583917 http://dx.doi.org/10.2196/jmir.2222 Text en ©Marcin Masalski, Tomasz Kręcicki. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 12.04.2013. http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Masalski, Marcin
Kręcicki, Tomasz
Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title_full Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title_fullStr Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title_full_unstemmed Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title_short Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis
title_sort self-test web-based pure-tone audiometry: validity evaluation and measurement error analysis
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3636315/
https://www.ncbi.nlm.nih.gov/pubmed/23583917
http://dx.doi.org/10.2196/jmir.2222
work_keys_str_mv AT masalskimarcin selftestwebbasedpuretoneaudiometryvalidityevaluationandmeasurementerroranalysis
AT krecickitomasz selftestwebbasedpuretoneaudiometryvalidityevaluationandmeasurementerroranalysis